124 research outputs found

    Bericht ueber eine neue Ultrahochvakuumaufdampfanlage

    Get PDF

    Varus inclination of the proximal tibia or the distal femur does not influence high tibial osteotomy outcome

    Get PDF
    We have analysed retrospectively the influence of different sources of knee deformity on failure of closing wedge high tibial valgus osteotomy (HTO). Preoperative frontal plane varus deformities of the lower extremity, distal femur and proximal tibia, and medial convergence of the knee joint line were assessed on a standard whole leg radiograph in 76 patients. Using the logistic regression model, the probability of survival for HTO was 77% (SD 4%) at 10-years follow-up. Varus deformity of the lower extremity ( 3 degrees ) were identified as preoperative risk factors for conversion to arthroplasty (P = 0.03 and P = 0.006). We found no evidence that varus inclination of the proximal tibia or distal femur influences long-term survival of HTO

    High tibial osteotomy in Sweden, 1998–2007: A population-based study of the use and rate of revision to knee arthroplasty

    Get PDF
    To access publisher's full text version of this article. Please click on the hyperlink in Additional Links field.Most studies on high tibial osteotomies (HTOs) have been hospital-based and have included a limited number of patients. We evaluated the use and outcome-expressed as rate of revision to knee arthroplasty-of HTO performed in Sweden with 9 million inhabitants, 1998-2007. 3, 161 HTO procedures on patients 30 years or older (69% men) who were operated on for knee osteoarthritis in Sweden, 1998-2007, were identified through the inpatient and outpatient care registers of the Swedish National Board of Health and Welfare. Pertinent data were verified through surgical records. Conversions of HTO to knee arthroplasty before 2010 were identified through the Swedish Knee Arthroplasty Register (SKAR). The 10-year survival was determined using revision to an arthroplasty as the endpoint. The number of HTOs decreased by one third between 1998 and 2007, from 388 operations a year to 257 a year. Most of the HTOs were performed with open wedge osteotomy using external fixation. The cumulative revision rate at 10 years was 30% (95% CI: 28-32). The risk of revision increased with increasing age and was higher in women than in men (RR = 1.3, CI: 1.1-1.5). If being without an artificial joint implant is considered to be beneficial, then HTO is an excellent alternative to knee arthroplasty in younger and/or physically active patients suffering from knee osteoarthritis.Swedish Research Council Swedish Rheumatism Association King Gustaf V 80-year Birthday Fund Faculty of Medicine, Lund University Region Skan

    Custom stems for femoral deformity in patients less than 40 years of age: 70 hips followed for an average of 14 years

    Get PDF
    Background and purpose Femoral deformity associated with osteoarthritis is a challenge for both the surgeon and the implant. Many of the patients with these deformities are young. Standard implants can be difficult to fit into these femurs. We prospectively evaluated the outcome of custom uncemented femoral stems in young patients

    Heterogeneity in clinical practices for post-cardiotomy extracorporeal life support: A pilot survey from the PELS-1 multicenter study

    Get PDF
    Background: High-quality evidence for post-cardiotomy extracorporeal life support (PC-ECLS) management is lacking. This study investigated real-world PC-ECLS clinical practices. Methods: This cross-sectional, multi-institutional, international pilot survey explored center organization, anticoagulation management, left ventricular unloading, distal limb perfusion, PC-ECLS monitoring, and transfusion practices. Twenty-nine questions were distributed among 34 hospitals participating in the Post-cardiotomy Extra-Corporeal Life Support Study. Results: Of the 32 centers [16 low-volume (50%); 16 high-volume (50%)] that responded, 16 (50%) had dedicated ECLS specialists. Twenty-six centers (81.3%) reported using additional mechanical circulatory supports. Anticoagulation practices were highly heterogeneous: 24 hospitals (75%) reported using patients bleeding status as a guide, without a specific threshold in 54.2% of cases. Transfusion targets ranged from 7 to 10 g/dL. Most centers used cardiac venting on a case-by-case basis (78.1%) and regular distal limb perfusion (84.4%). Nineteen (54.9%) centers reported dedicated monitoring protocols, including daily echocardiography (87.5%), Swan-Ganz catheterization (40.6%), cerebral near-infrared spectroscopy (53.1%), and multimodal assessment of limb ischemia. Inspection of the circuit (71.9%), oxygenator pressure drop (68.8%), plasma free hemoglobin (75%), d-dimer (59.4%), lactate dehydrogenase (56.3%), and fibrinogen (46.9%) are used to diagnose hemolysis and thrombosis. Conclusions: This study shows remarkable heterogeneity in clinical practices for PC-ECLS management. More standardized protocols and better implementation of the available evidence are recommended

    Estimating the closed skew-normal distributions parameters using weighted moments

    No full text
    International audienceSkewness is often present in a wide range of applied problems. One possible approach to model this skewness is based on the class of skew normal distributions. Fitting such distributions remains an inference challenge in various cases. In this paper, we propose and study novel estimators using weighted moments for the closed multivariate skew-normal distribution

    Truncated skew-normal distributions: moments, estimation by weighted moments and application to climatic data

    No full text
    International audienceIn this paper we derive an expression of the mth order moments and some weighted moments of truncated skew-normal distributions. We link these formulas to previous results for truncated distributions and non truncated skew-normal distri- butions. Methods to estimate skew-normal parameters using weighted moments are proposed and compared to other classical techniques. In a second step we propose to model the distribution of relative humidity with a truncated skew-normal distributio
    corecore