6 research outputs found

    Impact of COVID-19 on incidence and outcomes of post-infarction mechanical complications in Europe

    Get PDF
    OBJECTIVES Post-acute myocardial infarction mechanical complications (post-AMI MCs) represent rare but life-threatening conditions, including free-wall rupture, ventricular septal rupture and papillary muscle rupture. During the coronavirus disease-19 (COVID-19) pandemic, an overwhelming pressure on healthcare systems led to delayed and potentially suboptimal treatments for time-dependent conditions. As AMI-related hospitalizations decreased, limited information is available whether higher rates of post-AMI MCs and related deaths occurred in this setting. This study was aimed to assess how COVID-19 in Europe has impacted the incidence, treatment and outcome of MCs. METHODS The CAUTION-COVID19 study is a multicentre retrospective study collecting 175 patients with post-AMI MCs in 18 centres from 6 European countries, aimed to compare the incidence of such events, related patients' characteristics, and outcomes, between the first year of pandemic and the 2 previous years. RESULTS A non-significant increase in MCs was observed [odds ratio (OR) = 1.15, 95% confidence interval (CI) 0.85-1.57; P = 0.364], with stronger growth in ventricular septal rupture diagnoses (OR = 1.43, 95% CI 0.95-2.18; P = 0.090). No significant differences in treatment types and mortality were found between the 2 periods. In-hospital mortality was 50.9% and was higher for conservatively managed cases (90.9%) and lower for surgical patients (44.0%). Patients admitted during COVID-19 more frequently had late-presenting infarction (OR = 2.47, 95% CI 1.24-4.92; P = 0.010), more stable conditions (OR = 2.61, 95% CI 1.27-5.35; P = 0.009) and higher EuroSCORE II (OR = 1.04, 95% CI 1.01-1.06; P = 0.006). CONCLUSIONS A non-significant increase in MCs incidence occurred during the first year of COVID-19, characterized by a significantly higher rate of late-presenting infarction, stable conditions and EuroSCORE-II if compared to pre-pandemic data, without affecting treatment and mortality

    New echocardiographic screening tool for left ventricular tract obstruction risk assessment in TMVR

    No full text
    Background: Transcatheter mitral valve replacement (TMVR) is an alternative to conventional surgery to treat severe mitral disease but its use is limited by the risk of left ventricular outflow tract obstruction (LVOTO). Screening depends on ECG-gated computed tomography (CT) that is not widely available and requires contrast. We developed and validated a transthoracic echocardiographic (TTE) method to assess the risk of LVOTO after TMVR with the Tendyne System. Methods: We measured the LVOT longitudinal area on preoperative TTE dataset of patients screened for TMVR. The LVOT was measured as the box-area included by the aortic valve annulus, the anterior mitral leaflet (AML), the c-septum distance line, and the respective length of the AML on the interventricular septum. We analyzed the correlation between the TTE LVOT-box and the CT-measured neoLVOT area. Prediction performance for eligible patients was tested with ROC curves. Results: Thirty-nine patients were screened, out of 14 patients (36%) not eligible for TMVR, 8 had risk of LVOTO. We found a linear correlation between the TTE LVOT-box and the CT-measured Neo-LVOT (r = 0.6, p = 0.002). ROC curve showed that the method is specific and sensitive and the cut-off value of the measure LVOT-box is 350 mm2. Conclusions: The proposed method is reliable to evaluate the risk of LVOTO after TMR with the Tendyne System. It is quick and easy and can be used as a first-line assessment in the outpatient clinic. Patients with LVOT-box <350 mm2 should not be further screened with ECG-gated cardiac CT

    Platelet Reduction after Transcatheter Aortic Valve Implantation: Results from the PORTRAIT Study

    No full text
    Background: An unexplained condition that follows transcatheter aortic valve implantation (TAVI) is platelet count reduction (PR). According to published research, patients with balloon-expandable valves (BEVs) had a greater PR than those with self-expandable valves (SEVs). Objectives: The purpose of this study was to investigate the incidence and clinical effects of PR following TAVI. Methods: In total, 1.122 adult TAVI patients were enrolled. Propensity score matching was carried out in a 1:1 ratio between patients with BEVs and those with SEVs. The analysis included changes in platelet count, in-hospital mortality, and early postoperative adverse events. Results: Notably, 632 patients were matched (BEV:316; SEV:316). All patients' post-procedural platelet counts changed according to a parabolic curve, using a mixed regression model for repeated analyses (estimate = -0.931; standard error = 0.421; p = 0.027). The platelet count varied comparably in patients with BEVs and SEVs (estimate = -4.276, standard error = 4.760, p = 0.369). The average time for obtaining the nadir platelet count value was three days after implantation (BEV: 146 (108-181) vs. SEV: 149 (120-186); p = 0.142). Overall, 14.6% of patients (92/632) had post-procedural platelet count <100,000/L. There was no difference between the two prosthesis types (BEV:51/316; SEV:41/316; p = 0.266). Thrombocytopenia was found to be significantly linked to blood product transfusions, lengthier stays in the intensive care unit and hospital, and in-hospital mortality. Conclusions: TAVI, irrespective of the type of implanted valve, is linked to a significant but temporary PR. Thrombocytopenia increases the risk of serious complications and in-hospital death in TAVI patients. To explore and clarify the causes and associated effects, further prospective research is necessary

    Platelet Reduction after Aortic Bioprosthesis Implantation: Results from the PORTRAIT Study

    No full text
    Background: Platelet count reduction (PR) is a common but unclear phenomenon that occurs after aortic bioprosthesis valve implantation (bio-AVR). This study aimed to investigate the occurrence and clinical impact of PR in patients receiving stented, rapid deployment (RDV), or stentless bioprostheses. Methods: 1233 adult bio-AVR patients were enrolled. Platelet count variation, early post-operative adverse events, and in-hospital mortality were analysed. Results: 944 patients received a stented valve, an RDV was implanted in 218 patients, and 71 patients had a stentless bioprosthesis. In all groups, the platelet count at discharge was lower than the baseline values (p < 0.001). The percentage of PR was 27% in the stented group, 56% in the RDV group, and 55% in the stentless group. A higher platelet reduction, reaching the minimum platelet value, was observed in the RDV (mean: -30.84, standard error (SE): 5.91, p < 0.001) and stentless (mean: 22.54, SE: 9.10, p = 0.03) groups compared to the stented group. A greater PR occurred as the size of the bioprosthesis increased in RDV (p = 0.01), while platelet count variation was not directly proportional to the stented bioprosthesis size (p < 0.001). PR was not affected by cardiopulmonary bypass (mean: -0.00, SE: 0.001, p = 0.635) or cross-clamp (mean: -0.00, SE: 0.002, p = 0.051) times in any of the groups. RDV subjects experienced more in-hospital adverse events. PR was found to be associated with ischemic strokes in the overall population. Conclusions: Bio-AVR is associated with significant but transient PR. RDV patients more likely experience significant PR and related adverse clinical events. PR is associated with ischemic strokes, regardless of the bioprosthesis type

    Survival and Recurrence of Endocarditis following Mechanical vs. Biological Aortic Valve Replacement for Endocarditis in Patients Aged 40 to 65 Years: Data from the INFECT-Registry

    No full text
    Background: Infective endocarditis (IE) is a serious disease, and in many cases, surgery is necessary. Whether the type of prosthesis implanted for aortic valve replacement (AVR) for IE impacts patient survival is a matter of debate. The aim of the present study is to quantify differences in long-term survival and recurrence of endocarditis AVR for IE according to prosthesis type among patients aged 40 to 65 years. Methods: This was an analysis of the INFECT-REGISTRY. Trends in proportion to the use of mechanical prostheses versus biological ones over time were tested by applying the sieve bootstrapped t-test. Confounders were adjusted using the optimal full-matching propensity score. The difference in overall survival was compared using the Cox model, whereas the differences in recurrence of endocarditis were evaluated using the Gray test. Results: Overall, 4365 patients were diagnosed and operated on for IE from 2000 to 2021. Of these, 549, aged between 40 and 65 years, underwent AVR. A total of 268 (48.8%) received mechanical prostheses, and 281 (51.2%) received biological ones. A significant trend in the reduction of implantation of mechanical vs. biological prostheses was observed during the study period (p < 0.0001). Long-term survival was significantly higher among patients receiving a mechanical prosthesis than those receiving a biological prosthesis (hazard ratio [HR] 0.546, 95% CI: 0.322-0.926, p = 0.025). Mechanical prostheses were associated with significantly less recurrent endocarditis after AVR than biological prostheses (HR 0.268, 95%CI: 0.077-0.933, p = 0.039). Conclusions: The present analysis of the INFECT-REGISTRY shows increased survival and reduced recurrence of endocarditis after a mechanical aortic valve prosthesis implant for IE in middle-aged patients
    corecore