602 research outputs found

    Long Term Monitoring of CFA Energy Pile Schemes in the UK

    Get PDF
    Energy pile schemes involve the use of structural foundations as heat exchangers in a ground source heat pump system. Such schemes are attractive, as they reduce energy consumption compared with traditional building heating and cooling systems. As energy prices increase and governments introduce subsidies they are also proving increasingly economically attractive. Additionally, energy piles can contribute to reducing the carbon dioxide emissions associated with a development. However, this approach to heating and cooling building remains relatively novel and the lack of published long term performance data remains a barrier to further implementation. Two issues remain to be addressed by long term monitoring. First, the need for a database of operational energy piles schemes were the energy performance is proven over many years. Secondly, availability of long term datasets of pile thermal behavior that can be used to validate design approaches and tools and hence encourage less conservative design practices. This paper presents the initial results from a study aimed at tackling these issues through long term instrumentation and monitoring of two energy pile schemes in the United Kingdom

    2D thermal resistance of pile heat exchangers

    Get PDF
    Structural foundation piles are being used increasingly as heat exchangers to provide renewable heat for new buildings. To design such energy systems a steady state is assumed within the pile, which is conventionally characterised by constant thermal resistance. However, there has been little research regarding pile resistance and there are few published case studies. Numerical modelling results are presented here to provide typical values of pile resistance, depending on the details of the heat exchange pipes. Analysis suggests large diameter piles may take several days to reach steady state; in these cases a transient design approach may be more appropriate

    A resistive-capacitive model of pile heat exchangers with an application to thermal response tests interpretation

    Get PDF
    Pile Heat Exchangers (PHE) are an attractive solution to reduce both costs and greenhouse gas emissions for new buildings. However, most state-or-the-art PHE thermal models overlook the heat capacitance of the pile concrete, which is known to be important in thermal analysis. A semi-analytical (SA) model accounting for the pile concrete inertia is developed and validated against a finite-element code. Analysis shows that accounting for PHE inertia always leads to higher performances compared to purely resistive models. Application of the model to interpretation of thermal response tests data allows estimates to be made of the minimum duration test required to obtain reliable values of ground and concrete conductivities

    A new modelling approach for piled and other ground heat exchanger applications

    Get PDF
    Pile heat exchangers have an increasing role to play in the delivery of renewable heating and cooling energy. Traditionally the thermal design of ground heat exchangers has relied upon analytical approaches which take a relatively simple approach to the inside of the heat exchanger. This approach is justified while the heat exchanger diameter remains small. However, as larger diameter piled foundations are used as heat exchangers, the transient heat transfer processes operating within the pile become more important. To increase our understanding of these processes and ultimately lead to improved thermal design approaches for pile heat exchangers it is important to examine the heat transfer within the pile in detail. To accomplish this, a new numerical approach has been implemented within the finite element software ABAQUS. Coupling of the convective heat transfer due to fluid flow within the heat transfer pipes and the heat transfer by conduction within the pile concrete is the most important facet of the model. The resulting modelling approach, which is ready to generalise to other geothermal applications and to assess thermo-mechanical couplings, has been validated against a multi-stage thermal response test carried out on a test pile in London Clay

    Numerical analysis of thermal cycling during a multi-stage energy pile thermal response test

    Get PDF
    Energy piles are emerging as convenient alternative to the more traditional borehole heat exchangers (BHEs) to provide heating/cooling to buildings, as they remove the need for special purpose excavations and can accommodate more pipes, thus enhancing energy performance. However, their different aspect ratio compared to BHEs requires different modelling tools and dedicated thermal response testing, to achieve adequate thermal design. In this work, the results of an extended multi-stage thermal response test (TRT) carried out on a single energy pile installed in London Clay are presented in terms of both fluid temperature data and concrete temperature, measured by vibrating wire strain gauges and optic fibre sensors. The results are then explored in detail by means of a finite element numerical code, able to account for both convective heat exchange in the fluid, between the fluid and the solids and transient heat diffusion in the concrete and the ground. Analysis of the TRT field data shows that during the later stages of the test there is clear evidence of cyclic changes in performance. Investigation of these effects using the numerical model raises the possibility that there could be some alteration of the properties of the soil-pile contact during the test. Hypotheses for the observed behaviour are tentatively put forward and discussed with work recommended to further investigate the percieved phenomena

    Reading Guide 7: Intervention strategies and business case

    Get PDF
    Earthworks deteriorate over time and are additionally subject to increasingly extreme weather conditions. A range of intervention types is available to maintain the safety and serviceability of earthworks assets, and these should be selected and made as cost-effectively as possible, to maximise asset condition improvement within the available budget

    Thermal Conductivity of Simulated Soils by the Needle Probe Method for Energy Foundation Applications

    Get PDF
    Soil thermal conductivity is an important parameter in the design of ground source heat pump and energy foundation systems. A laboratory method for measuring the soil thermal conductivity is the needle probe method. Earlier, analysis of the needle probe test data has been simplistic, relying heavily on human judgment and rules of thumb. This article presents an alternative method of analyzing the needle probe data with the aid of MATLAB, which is a technical programming language and computing environment. Four agar–kaolin specimens of varying densities were prepared to resemble simple soils. These were tested using the needle probe for a range of heating times and heating powers, to see what effect these parameters would have on the results. The repeatability when keeping the heating time and heating power constant was within ±2%. When the heating time and heating power were varied, the variation in results from the average for a given specimen ranged from ±4% to +10%/–8%. This range is significantly higher than the repeatability. Possible reasons for this are discussed in this article

    Evaluating the Applicability of the Radial Approximation for Pile Heat Exchangers

    Get PDF
    This paper appraises the efficacy of using an analytical radial approximation for different thermal pile heat exchanger geometries. Unsteady radial heat-flow from fluid in a pipe set within a grouted borehole into the external ground is well-documented and can be solved analytically very rapidly using Laplace Transforms (Javed and Claesson 2011). By comparing the radial model with finite-element simulations including explicit pile geometries, this paper provides a provisional analysis of the accuracy of this approach. Initial findings suggest that the radial model may provide an appropriate approximation to pile behaviour for certain pipe configurations, albeit with small ‘mid-time’ error

    Bayesian estimates of male and female African lion mortality for future use in population management

    Get PDF
    The global population size of African lions is plummeting, and many small fragmented populations face local extinction. Extinction risks are amplified through the common practice of trophy hunting for males, which makes setting sustainable hunting quotas a vital task. Various demographic models evaluate consequences of hunting on lion population growth. However, none of the models use unbiased estimates of male age-specific mortality because such estimates do not exist. Until now, estimating mortality from resighting records of marked males has been impossible due to the uncertain fates of disappeared individuals: dispersal or death. We develop a new method and infer mortality for male and female lions from two populations that are typical with respect to their experienced levels of human impact. We found that mortality of both sexes differed between the populations and that males had higher mortality across all ages in both populations. We discuss the role that different drivers of lion mortality may play in explaining these differences and whether their effects need to be included in lion demographic models. Synthesis and applications. Our mortality estimates can be used to improve lion population management and, in addition, the mortality model itself has potential applications in demographically informed approaches to the conservation of species with sex-biased dispersal. Our mortality estimates can be used to improve lion population management and, in addition, the mortality model itself has potential applications in demographically informed approaches to the conservation of species with sex-biased dispersal. Journal of Applied Ecology. © 2016 British Ecological Society
    • …
    corecore