2 research outputs found
Role of the Carotid Bodies in the Hypertensive and Natriuretic Responses to NaCl Load in Conscious Rats
Hyperosmotic challenges trigger a hypertensive response and natriuresis mediated by central and peripheral sensors. Here, we evaluated the importance of the carotid bodies for the hypertensive and natriuretic responses to acute and sub-chronic NaCl load in conscious rats. Male Wistar rats (250–330 g) submitted to bilateral carotid body removal (CBX) or sham surgery were used. One day after the surgery, the changes in arterial blood pressure (n = 6–7/group) and renal sodium excretion (n = 10/group) to intravenous infusion of 3 M NaCl (1.8 mL/kg b.w. during 1 min) were evaluated in non-anesthetized rats. Another cohort of sham (n = 8) and CBX rats (n = 6) had access to 0.3 M NaCl as the only source of fluid to drink for 7 days while ingestion and renal excretion were monitored daily. The sodium balance was calculated as the difference between sodium infused/ingested and excreted. CBX reduced the hypertensive (8 ± 2 mmHg, vs. sham rats: 19 ± 2 mmHg; p < 0.05) and natriuretic responses (1.33 ± 0.13 mmol/90 min, vs. sham: 1.81 ± 0.11 mmol/90 min; p < 0.05) to acute intravenous infusion of 3 M NaCl, leading to an increase of sodium balance (0.38 ± 0.11 mmol/90 min, vs. sham: -0.06 ± 0.10 mmol/90 min; p < 0.05). In CBX rats, sub-chronic NaCl load with 0.3 M NaCl to drink for 7 days increased sodium balance (18.13 ± 4.45 mmol, vs. sham: 5.58 ± 1.71 mmol; p < 0.05) and plasma sodium concentration (164 ± 5 mmol/L, vs. sham: 140 ± 7 mmol/L; p < 0.05), without changing arterial pressure (121 ± 9 mmHg, vs. sham: 116 ± 2 mmHg). These results suggest that carotid bodies are important for the maintenance of the hypertensive response to acute hypertonic challenges and for sodium excretion to both acute and chronic NaCl load
Alternative platforms for electrophoretic systems integrated with contactless conductivity detection
Submitted by Jaqueline Silva ([email protected]) on 2016-10-03T14:17:36Z
No. of bitstreams: 2
Dissertação - Eunício de Oliveira Lobo Junior - 2016.pdf: 5628245 bytes, checksum: cb5cfdfdb21a0a9bed0292decf6c094f (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)Approved for entry into archive by Jaqueline Silva ([email protected]) on 2016-10-03T14:18:22Z (GMT) No. of bitstreams: 2
Dissertação - Eunício de Oliveira Lobo Junior - 2016.pdf: 5628245 bytes, checksum: cb5cfdfdb21a0a9bed0292decf6c094f (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)Made available in DSpace on 2016-10-03T14:18:22Z (GMT). No. of bitstreams: 2
Dissertação - Eunício de Oliveira Lobo Junior - 2016.pdf: 5628245 bytes, checksum: cb5cfdfdb21a0a9bed0292decf6c094f (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2016-03-10Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPqThis report describes the development of two alternative platforms for electrophoretic runs in microsystems. Firstly, the development of a hybrid capillary system that dispenses microfabrication steps is presented using fused silica capillaries interconnected by a commercial crossed shape interface. This hybrid system was coupled with contactless conductivity detector (C4D) to allow the determination of inorganic cations in biological samples. Electrokinetic sample injection was performed through gated mode approach for the first time in this arrangement. Operational parameters such as: (i) wave frequency and amplitude applied in C4D system, (ii) electrical potential applied in injection, (iii) injection time, (iv) detection point, (v) effect of capillary conditioning as well as and (vi) recovery percentage were extensively investigated and optimized. Better separations of cationic mixture containing NH4+, K+, Na+, Ca2+ and Mg2+ were achieved using a buffer system composed of 50 mM Lactic Acid, 20 mM Histidine and 3 mM 18-crown-6 on a capillary with effective length of 14.5 cm. . Addition of internal standard was used to ensure analytical reproducibility and allow the recording of merit figures. Linear behaviors were observed in concentration ranges between 10 and 100 M for NH4+, K+, Ca2+ e Mg2+, and 20-200 M for Na+. The limit of detection values calculated were 3.75 μM (NH4+), 3.70 μM (K+), 7.50 μM (Na+), 5.00 μM (Ca2+) and 5.35 μM (Mg2+). The concentration levels achieved for cations in biological samples ranged from 4,1 μM to 200 μM. Besides the hybrid system, this report also describes the development of an alternative methodology for the fabrication of high-relief masters for soft-lithography in poly(dimethylsiloxane) (PDMS) substrate. One of the innovative features makes reference to the use of low cost commercial photoresist from textile industry - poly(vinyl acetate) (PVAc) - which exhibits low toxicity. PVAc films were deposited on printed cirtuitry boards through the use of a homemade spincoater developed by desktop cooler, with rotation time control. This methodology allowed the production of high relief masters and PDMS channels with width and depth of 50 μm and 40 μm, respectively. Channels and masters profiles They were characterized with the following techniques: scan electron microscopy, perfilometry, optical and electrical. PDMS electrophoresis devices were successfully used for the separation of major inorganic cations.Esta dissertação descreve o desenvolvimento de duas plataformas alternativas para a realização de eletroforese em microssistemas. Inicialmente é descrita um sistema eletroforético híbrido que dispensa etapas de microfabricação utilizando capilares de sílica fundida, conectados por uma interface comercial com formato em cruz. Este sistema capilar híbrido foi acoplado com detecção condutométrica sem contato (C4D) e aplicado na determinação de cátions inorgânicos (NH4+, K+, Na+, Ca2+, Mg2+) em amostras biológicas. A injeção de amostras foi realizada eletrocineticamente no modo gated, sendo o primeiro estudo em capilares utilizando esta modalidade de injeção. Foram avaliados os parâmetros operacionais de funcionamento do sistema incluindo (i) frequência e amplitude da onda senoidal aplicada ao sistema de detecção, (ii) potencial elétrico aplicado na injeção, (iii) tempo de injeção, (iv) composição do tampão, (v) ponto de detecção, (vi) efeito do condicionamento do capilar e (vii) recuperação. As melhores separações para uma mistura contendo os cátions inorgânicos foram obtidas usando-se um sistema tamponante composto de ácido lático 50 mM, histidina 20 mM e éter coroa (18-crown-6) 3 mM em um capilar com comprimento efetivo de 14,5 cm. As figuras de mérito analítico foram obtidas a partir da adição do íon Li+ como padrão interno, o qual assegurou confiabilidade nas análises quantitativas. A partir da otimização dos parâmetros analíticos, as curvas analíticas para os íons NH4+, K+, Ca2+ e Mg2+ exibiram comportamento linear (R2>0,99) na faixa de 10-100 M enquanto a curva analítica para o íon Na+ proporcionou resposta linear na faixa de 20-200 M. Os limites de detecção encontrados para os cinco cátions foram entre 3,75 μM (NH4+), 3,75 μM (K+), 7,50 μM (Na+), 5,00 μM (Ca2+) e 5,35 μM (Mg2+). O sistema desenvolvido foi explorado para a determinação dos cátions inorgânicos em amostras de urina, saliva e lágrimas. As concentrações encontradas nas amostras biológicas variaram de 4,1 μM a 200 μM. Além do sistema híbrido, a dissertação também apresenta uma metodologia de baixo custo para produção de moldes em alto relevo para litografia suave em poli(dimetilsiloxano) (PDMS). A principal inovação é o uso de fotoresiste de baixo custo, que se trata de uma emulsão fotossensível de poli(acetato de vinila) (PVAc) utilizada na indústria têxtil e que apresenta baixa toxicidade. Outra inovação é o controle da altura dos moldes utilizando um spincoater de produção própria, com controle de tempo de rotação. Com esta metodologia foram produzidos moldes em alto relevo, e microchips em PDMS com 50 μm de largura e 40 μm de altura. Foram realizadas separações eletroforéticas dos cátions NH4+,K+,Na+,Ca2+,Mg2+e Li+. As eficiências de separação variaram entre 73.000 e 120.000 pratos/m. O que comprova que a metodologia alternativa apresenta aplicabilidade microfluídic