40 research outputs found

    Reliability of IMU-Derived Static Balance Parameters in Neurological Diseases

    Get PDF
    Static balance is a commonly used health measure in clinical practice. Usually, static balance parameters are assessed via force plates or, more recently, with inertial measurement units (IMUs). Multiple parameters have been developed over the years to compare patient groups and understand changes over time. However, the day-to-day variability of these parameters using IMUs has not yet been tested in a neurogeriatric cohort. The aim of the study was to examine day-to-day variability of static balance parameters of five experimental conditions in a cohort of neurogeriatric patients using data extracted from a lower back-worn IMU. A group of 41 neurogeriatric participants (age: 78 ± 5 years) underwent static balance assessment on two occasions 12-24 h apart. Participants performed a side-by-side stance, a semi-tandem stance, a tandem stance on hard ground with eyes open, and a semi-tandem assessment on a soft surface with eyes open and closed for 30 s each. The intra-class correlation coefficient (two-way random, average of the k raters' measurements, ICC2, k) and minimal detectable change at a 95% confidence level (MDC95%) were calculated for the sway area, velocity, acceleration, jerk, and frequency. Velocity, acceleration, and jerk were calculated in both anterior-posterior (AP) and medio-lateral (ML) directions. Nine to 41 participants could successfully perform the respective balance tasks. Considering all conditions, acceleration-related parameters in the AP and ML directions gave the highest ICC results. The MDC95% values for all parameters ranged from 39% to 220%, with frequency being the most consistent with values of 39-57%, followed by acceleration in the ML (43-55%) and AP direction (54-77%). The present results show moderate to poor ICC and MDC values for IMU-based static balance assessment in neurogeriatric patients. This suggests a limited reliability of these tasks and parameters, which should induce a careful selection of potential clinically relevant parameters

    Molecular Classification of Neuroendocrine Tumors of the Thymus

    Get PDF
    INTRODUCTION: The WHO classification of pulmonary neuroendocrine tumors (PNETs) is also used to classify thymic NETs (TNETs) into typical and atypical carcinoid (TC and AC), large cell neuroendocrine carcinoma (LCNEC), and small cell carcinoma (SCC), but little is known about the usability of alternative classification systems. METHODS: One hundred seven TNET (22 TC, 51 AC, 28 LCNEC, and 6 SCC) from 103 patients were classified according to the WHO, the European Neuroendocrine Tumor Society, and a grading-related PNET classification. Low coverage whole-genome sequencing and immunohistochemical studies were performed in 63 cases. A copy number instability (CNI) score was applied to compare tumors. Eleven LCNEC were further analyzed using targeted next-generation sequencing. Morphologic classifications were tested against molecular features. RESULTS: Whole-genome sequencing data fell into three clusters: CNIlow, CNIint, and CNIhigh. CNIlow and CNIint comprised not only TC and AC, but also six LCNECs. CNIhigh contained all SCC and nine LCNEC, but also three AC. No morphologic classification was able to predict the CNI cluster. Cases where primary tumors and metastases were available showed progression from low-grade to higher-grade histologies. Analysis of LCNEC revealed a subgroup of intermediate NET G3 tumors that differed from LCNEC by carcinoid morphology, expression of chromogranin, and negativity for enhancer of zeste 2 polycomb repressive complex 2 subunit (EZH2). CONCLUSIONS: TNETs fall into three molecular subgroups that are not reflected by the current WHO classification. Given the large overlap between TC and AC on the one hand, and AC and LCNEC on the other, we propose a morphomolecular grading system, Thy-NET G1-G3, instead of histologic classification for patient stratification and prognostication. peerReviewe

    Data sharing in neurodegenerative disease research: challenges and learnings from the innovative medicines initiative public-private partnership model

    Get PDF
    Efficient data sharing is hampered by an array of organizational, ethical, behavioral, and technical challenges, slowing research progress and reducing the utility of data generated by clinical research studies on neurodegenerative diseases. There is a particular need to address differences between public and private sector environments for research and data sharing, which have varying standards, expectations, motivations, and interests. The Neuronet data sharing Working Group was set up to understand the existing barriers to data sharing in public-private partnership projects, and to provide guidance to overcome these barriers, by convening data sharing experts from diverse projects in the IMI neurodegeneration portfolio. In this policy and practice review, we outline the challenges and learnings of the WG, providing the neurodegeneration community with examples of good practices and recommendations on how to overcome obstacles to data sharing. These obstacles span organizational issues linked to the unique structure of cross-sectoral, collaborative research initiatives, to technical issues that affect the storage, structure and annotations of individual datasets. We also identify sociotechnical hurdles, such as academic recognition and reward systems that disincentivise data sharing, and legal challenges linked to heightened perceptions of data privacy risk, compounded by a lack of clear guidance on GDPR compliance mechanisms for public-private research. Focusing on real-world, neuroimaging and digital biomarker data, we highlight particular challenges and learnings for data sharing, such as data management planning, development of ethical codes of conduct, and harmonization of protocols and curation processes. Cross-cutting solutions and enablers include the principles of transparency, standardization and co-design – from open, accessible metadata catalogs that enhance findability of data, to measures that increase visibility and trust in data reuse

    Fatigue-Related Changes of Daily Function: Most Promising Measures for the Digital Age

    Get PDF
    Background: Fatigue is a prominent symptom in many diseases and is strongly associated with impaired daily function. The measurement of daily function is currently almost always done with questionnaires, which are subjective and imprecise. With the recent advances of digital wearable technologies, novel approaches to evaluate daily function quantitatively and objectively in real-life conditions are increasingly possible. This also creates new possibilities to measure fatigue-related changes of daily function using such technologies. Summary: This review examines which digitally assessable parameters in immune-mediated inflammatory and neurodegenerative diseases may have the greatest potential to reflect fatigue-related changes of daily function. Key Messages: Results of a standardized analysis of the literature reporting about perception-, capacity-, and performance-evaluating assessment tools indicate that changes of the following parameters: physical activity, independence of daily living, social participation, working life, mental status, cognitive and aerobic capacity, and supervised and unsupervised mobility performance have the highest potential to reflect fatigue-related changes of daily function. These parameters thus hold the greatest potential for quantitatively measuring fatigue in representative diseases in real-life conditions, e.g., with digital wearable technologies. Furthermore, to the best of our knowledge, this is a new approach to analysing evidence for the design of performance-based digital assessment protocols in human research, which may stimulate further systematic research in this area

    Meta-analysis of real-time fMRI neurofeedback studies using individual participant data: How is brain regulation mediated?

    Get PDF
    An increasing number of studies using real-time fMRI neurofeedback have demonstrated that successful regulation of neural activity is possible in various brain regions. Since these studies focused on the regulated region(s), little is known about the target-independent mechanisms associated with neurofeedback-guided control of brain activation, i.e. the regulating network. While the specificity of the activation during self-regulation is an important factor, no study has effectively determined the network involved in self-regulation in general. In an effort to detect regions that are responsible for the act of brain regulation, we performed a post-hoc analysis of data involving different target regions based on studies from different research groups. We included twelve suitable studies that examined nine different target regions amounting to a total of 175 subjects and 899 neurofeedback runs. Data analysis included a standard first- (single subject, extracting main paradigm) and second-level (single subject, all runs) general linear model (GLM) analysis of all participants taking into account the individual timing. Subsequently, at the third level, a random effects model GLM included all subjects of all studies, resulting in an overall mixed effects model. Since four of the twelve studies had a reduced field of view (FoV), we repeated the same analysis in a subsample of eight studies that had a well-overlapping FoV to obtain a more global picture of self-regulation. The GLM analysis revealed that the anterior insula as well as the basal ganglia, notably the striatum, were consistently active during the regulation of brain activation across the studies. The anterior insula has been implicated in interoceptive awareness of the body and cognitive control. Basal ganglia are involved in procedural learning, visuomotor integration and other higher cognitive processes including motivation. The larger FoV analysis yielded additional activations in the anterior cingulate cortex, the dorsolateral and ventrolateral prefrontal cortex, the temporo-parietal area and the visual association areas including the temporo-occipital junction. In conclusion, we demonstrate that several key regions, such as the anterior insula and the basal ganglia, are consistently activated during self-regulation in real-time fMRI neurofeedback independent of the targeted region-of-interest. Our results imply that if the real-time fMRI neurofeedback studies target regions of this regulation network, such as the anterior insula, care should be given whether activation changes are related to successful regulation, or related to the regulation process per se. Furthermore, future research is needed to determine how activation within this regulation network is related to neurofeedback success

    Assessing fatigue and sleep in chronic diseases using physiological signals from wearables : A pilot study

    Get PDF
    Problems with fatigue and sleep are highly prevalent in patients with chronic diseases and often rated among the most disabling symptoms, impairing their activities of daily living and the health-related quality of life (HRQoL). Currently, they are evaluated primarily via Patient Reported Outcomes (PROs), which can suffer from recall biases and have limited sensitivity to temporal variations. Objective measurements from wearable sensors allow to reliably quantify disease state, changes in the HRQoL, and evaluate therapeutic outcomes. This work investigates the feasibility of capturing continuous physiological signals from an electrocardiography-based wearable device for remote monitoring of fatigue and sleep and quantifies the relationship of objective digital measures to self-reported fatigue and sleep disturbances. 136 individuals were followed for a total of 1,297 recording days in a longitudinal multi-site study conducted in free-living settings and registered with the German Clinical Trial Registry (DRKS00021693). Participants comprised healthy individuals (N = 39) and patients with neurodegenerative disorders (NDD, N = 31) and immune mediated inflammatory diseases (IMID, N = 66). Objective physiological measures correlated with fatigue and sleep PROs, while demonstrating reasonable signal quality. Furthermore, analysis of heart rate recovery estimated during activities of daily living showed significant differences between healthy and patient groups. This work underscores the promise and sensitivity of novel digital measures from multimodal sensor time-series to differentiate chronic patients from healthy individuals and monitor their HRQoL. The presented work provides clinicians with realistic insights of continuous at home patient monitoring and its practical value in quantitative assessment of fatigue and sleep, an area of unmet need.publishedVersionPeer reviewe

    Mobilise-D insights to estimate real-world walking speed in multiple conditions with a wearable device

    Get PDF
    This study aimed to validate a wearable device’s walking speed estimation pipeline, considering complexity, speed, and walking bout duration. The goal was to provide recommendations on the use of wearable devices for real-world mobility analysis. Participants with Parkinson’s Disease, Multiple Sclerosis, Proximal Femoral Fracture, Chronic Obstructive Pulmonary Disease, Congestive Heart Failure, and healthy older adults (n = 97) were monitored in the laboratory and the real-world (2.5 h), using a lower back wearable device. Two walking speed estimation pipelines were validated across 4408/1298 (2.5 h/laboratory) detected walking bouts, compared to 4620/1365 bouts detected by a multi-sensor reference system. In the laboratory, the mean absolute error (MAE) and mean relative error (MRE) for walking speed estimation ranged from 0.06 to 0.12 m/s and − 2.1 to 14.4%, with ICCs (Intraclass correlation coefficients) between good (0.79) and excellent (0.91). Real-world MAE ranged from 0.09 to 0.13, MARE from 1.3 to 22.7%, with ICCs indicating moderate (0.57) to good (0.88) agreement. Lower errors were observed for cohorts without major gait impairments, less complex tasks, and longer walking bouts. The analytical pipelines demonstrated moderate to good accuracy in estimating walking speed. Accuracy depended on confounding factors, emphasizing the need for robust technical validation before clinical application. Trial registration: ISRCTN – 12246987

    Improvement of real-time fMRI neurofeedback for clinical applications

    No full text
    Le neurofeedback en temps réel d'imagerie par résonance magnétique fonctionnelle (IRMf) est une procédure expérimentale permettant aux participants de gagner un contrôle volontaire sur l'activation d'une région, ou d'un réseau, de leur cerveau. Dans ma these j'explore plusieurs points d'intérêt actuels du neurofeedback en temps réel d'IRMf, notamment les régions du cerveau qui facilitent l'auto-régulation, le choix de la région cible, l'influence des traits de personnalité et des habitudes sur le succès du neurofeedback et la présentation de feedback optimale. Au vu des résultats, de futures études devraient optimiser leur mise en place en présélectionnant ou en entraînant au préalable les participants selon des facteurs comportementaux, et en perfectionnant le timing de la présentation du feedback. Améliorer ainsi le neurofeedback en temps réel d'IRMf pourrait augmenter la force de régulation, aidant ainsi à propulser le neurofeedback vers un rôle de traitement supplémentaire pour de nombreuses pathologies du cerveau
    corecore