74 research outputs found

    Opportunities for addressing gaps in primary care shared decision-making with technology: a mixed-methods needs assessment

    Get PDF
    Objectives: To analyze current practices in shared decision-making (SDM) in primary care and perform a needs assessment for the role of information technology (IT) interventions. Materials and Methods: A mixed-methods study was conducted in three phases: (1) ethnographic observation of clinical encounters, (2) patient interviews, and (3) physician interviews. SDM was measured using the validated OPTION scale. Semistructured interviews followed an interview guide (developed by our multidisciplinary team) informed by the Traditional Decision Conflict Scale and Shared Decision Making Questionnaire. Field notes were independently coded and analyzed by two reviewers in Dedoose. Results: Twenty-four patient encounters were observed in 3 diverse practices with an average OPTION score of 57.2 (0–100 scale; 95% confidence interval [CI], 51.8–62.6). Twenty-two patient and 8 physician interviews were conducted until thematic saturation was achieved. Cohen’s kappa, measuring coder agreement, was 0.42. Patient domains were: establishing trust, influence of others, flexibility, frustrations, values, and preferences. Physician domains included frustrations, technology (concerns, existing use, and desires), and decision making (current methods used, challenges, and patients’ understanding). Discussion: Given low SDM observed, multiple opportunities for technology to enhance SDM exist based on specific OPTION items that received lower scores, including: (1) checking the patient’s preferred information format, (2) asking the patient's preferred level of involvement in decision making, and (3) providing an opportunity for deferring a decision. Based on data from interviews, patients and physicians value information exchange and are open to technologies that enhance communication of care options. Conclusion: Future primary care IT platforms should prioritize the 3 quantitative gaps identified to improve physician–patient communication and relationships. Additionally, SDM tools should seek to standardize common workflow steps across decisions and focus on barriers to increasing adoption of effective SDM tools into routine primary care

    Identifying and addressing barriers to implementing core electronic health record use metrics for ambulatory care: Virtual consensus conference proceedings

    Get PDF
    Precise, reliable, valid metrics that are cost-effective and require reasonable implementation time and effort are needed to drive electronic health record (EHR) improvements and decrease EHR burden. Differences exist between research and vendor definitions of metrics. PROCESS:  We convened three stakeholder groups (health system informatics leaders, EHR vendor representatives, and researchers) in a virtual workshop series to achieve consensus on barriers, solutions, and next steps to implementing the core EHR use metrics in ambulatory care. CONCLUSION:  Actionable solutions identified to address core categories of EHR metric implementation challenges include: (1) maintaining broad stakeholder engagement, (2) reaching agreement on standardized measure definitions across vendors, (3) integrating clinician perspectives, and (4) addressing cognitive and EHR burden. Building upon the momentum of this workshop\u27s outputs offers promise for overcoming barriers to implementing EHR use metrics

    An Esrrb and nanog cell fate regulatory module controlled by feed forward loop interactions

    Get PDF
    Cell fate decisions during development are governed by multi-factorial regulatory mechanisms including chromatin remodeling, DNA methylation, binding of transcription factors to specific loci, RNA transcription and protein synthesis. However, the mechanisms by which such regulatory 'dimensions' coordinate cell fate decisions are currently poorly understood. Here we quantified the multi-dimensional molecular changes that occur in mouse embryonic stem cells (mESCs) upon depletion of Estrogen related receptor beta (Esrrb), a key pluripotency regulator. Comparative analyses of expression changes subsequent to depletion of Esrrb or Nanog, indicated that a system of interlocked feed-forward loops involving both factors, plays a central part in regulating the timing of mESC fate decisions. Taken together, our meta-analyses support a hierarchical model in which pluripotency is maintained by an Oct4-Sox2 regulatory module, while the timing of differentiation is regulated by a Nanog-Esrrb module

    Accounting for quality improvement during the conduct of embedded pragmatic clinical trials within healthcare systems: NIH Collaboratory case studies

    Get PDF
    Embedded pragmatic clinical trials (ePCTs) and quality improvement (QI) activities often occur simultaneously within healthcare systems (HCSs). Embedded PCTs within HCSs are conducted to test interventions and provide evidence that may impact public health, health system operations, and quality of care. They are larger and more broadly generalizable than QI initiatives, and may generate what is considered high-quality evidence for potential use in care and clinical practice guidelines. QI initiatives often co-occur with ePCTs and address the same high-impact health questions, and this co-occurrence may dilute or confound the ability to detect change as a result of the ePCT intervention. During the design, pilot, and conduct phases of the large-scale NIH Collaboratory Demonstration ePCTs, many QI initiatives occurred at the same time within the HCSs. Although the challenges varied across the projects, some common, generalizable strategies and solutions emerged, and we share these as case studies. KEY LESSONS: Study teams often need to monitor, adapt, and respond to QI during design and the course of the trial. Routine collaboration between ePCT researchers and health systems stakeholders throughout the trial can help ensure research and QI are optimally aligned to support high-quality patient-centered care

    Origins Space Telescope: Baseline mission concept

    Get PDF
    The Origins Space Telescope will trace the history of our origins from the time dust and heavy elements permanently altered the cosmic landscape to present-day life. How did galaxies evolve from the earliest galactic systems to those found in the Universe today? How do habitable planets form? How common are life-bearing worlds? To answer these alluring questions, Origins will operate at mid-and far-infrared (IR) wavelengths and offer powerful spectroscopic instruments and sensitivity three orders of magnitude better than that of the Herschel Space Observatory, the largest telescope flown in space to date. We describe the baseline concept for Origins recommended to the 2020 US Decadal Survey in Astronomy and Astrophysics. The baseline design includes a 5.9-m diameter telescope cryocooled to 4.5 K and equipped with three scientific instruments. A mid-infrared instrument (Mid-Infrared Spectrometer and Camera Transit spectrometer) will measure the spectra of transiting exoplanets in the 2.8 to 20 μm wavelength range and offer unprecedented spectrophotometric precision, enabling definitive exoplanet biosignature detections. The far-IR imager polarimeter will be able to survey thousands of square degrees with broadband imaging at 50 and 250 μm. The Origins Survey Spectrometer will cover wavelengths from 25 to 588 μm, making wide-area and deep spectroscopic surveys with spectral resolving power R ∼ 300, and pointed observations at R ∼ 40,000 and 300,000 with selectable instrument modes. Origins was designed to minimize complexity. The architecture is similar to that of the Spitzer Space Telescope and requires very few deployments after launch, while the cryothermal system design leverages James Webb Space Telescope technology and experience. A combination of current-state-of-the-art cryocoolers and next-generation detector technology will enable Origins\u27 natural background-limited sensitivity

    Origins Space Telescope: baseline mission concept

    Get PDF
    The Origins Space Telescope will trace the history of our origins from the time dust and heavy elements permanently altered the cosmic landscape to present-day life. How did galaxies evolve from the earliest galactic systems to those found in the Universe today? How do habitable planets form? How common are life-bearing worlds? To answer these alluring questions, Origins will operate at mid- and far-infrared (IR) wavelengths and offer powerful spectroscopic instruments and sensitivity three orders of magnitude better than that of the Herschel Space Observatory, the largest telescope flown in space to date. We describe the baseline concept for Origins recommended to the 2020 US Decadal Survey in Astronomy and Astrophysics. The baseline design includes a 5.9-m diameter telescope cryocooled to 4.5 K and equipped with three scientific instruments. A mid-infrared instrument (Mid-Infrared Spectrometer and Camera Transit spectrometer) will measure the spectra of transiting exoplanets in the 2.8 to 20  μm wavelength range and offer unprecedented spectrophotometric precision, enabling definitive exoplanet biosignature detections. The far-IR imager polarimeter will be able to survey thousands of square degrees with broadband imaging at 50 and 250  μm. The Origins Survey Spectrometer will cover wavelengths from 25 to 588  μm, making wide-area and deep spectroscopic surveys with spectral resolving power R  ∼  300, and pointed observations at R  ∼  40,000 and 300,000 with selectable instrument modes. Origins was designed to minimize complexity. The architecture is similar to that of the Spitzer Space Telescope and requires very few deployments after launch, while the cryothermal system design leverages James Webb Space Telescope technology and experience. A combination of current-state-of-the-art cryocoolers and next-generation detector technology will enable Origins’ natural background-limited sensitivity
    corecore