18 research outputs found

    Glyceryl Monooleate/Poloxamer 407 Cubic Nanoparticles as Oral Drug Delivery Systems: I. In Vitro Evaluation and Enhanced Oral Bioavailability of the Poorly Water-Soluble Drug Simvastatin

    No full text
    Glyceryl monooleate (GMO)/poloxamer 407 cubic nanoparticles were investigated as potential oral drug delivery systems to enhance the bioavailability of the water-insoluble model drug simvastatin. The simvastatin-loaded cubic nanoparticles were prepared through fragmentation of the GMO/poloxamer 407 bulk cubic-phase gel using high-pressure homogenization. The internal structure of the cubic nanoparticles was identified by cryo-transmission electron microscopy. The mean diameter of the cubic nanoparticles varied within the range of 100–150 nm, and both GMO/poloxamer 407 ratio and theoretical drug loading had no significant effect on particle size and distribution. Almost complete entrapment with efficiency over 98% was achieved due to the high affinity of simvastatin to the hydrophobic regions of the cubic phase. Release of simvastatin from the cubic nanoparticles was limited both in 0.1 M hydrochloride solution containing 0.2% sodium lauryl sulfate and fasted-state simulated intestinal fluid with a total release of <3.0% at 10 h. Pharmacokinetic profiles in beagle dogs showed sustained plasma levels of simvastatin for cubic nanoparticles over 12 h. The relative oral bioavailability of simvastatin cubic nanoparticles calculated on the basis of area under the curve was 241% compared to simvastatin crystal powder. The enhancement of simvastatin bioavailability was possibly attributable to facilitated absorption by lipids in the formulation rather than improved release

    Characterization and intercomparison of aerosol absorption photometers: result of two intercomparison workshops

    No full text
    Absorption photometers for real time application have been available since the 1980s, but the use of filter-based instruments to derive information on aerosol properties (absorption coefficient and black carbon, BC) is still a matter of debate. Several workshops have been conducted to investigate the performance of individual instruments over the intervening years. Two workshops with large sets of aerosol absorption photometers were conducted in 2005 and 2007. The data from these instruments were corrected using existing methods before further analysis. The inter-comparison shows a large variation between the responses to absorbing aerosol particles for different types of instruments. The unit to unit variability between instruments can be up to 30% for Particle Soot Absorption Photometers (PSAPs) and Aethalometers. Multi Angle Absorption Photometers (MAAPs) showed a variability of less than 5%. Reasons for the high variability were identified to be variations in sample flow and spot size. It was observed that different flow rates influence system performance with respect to response to absorption and instrumental noise. Measurements with non absorbing particles showed that the current corrections of a cross sensitivity to particle scattering are not sufficient. Remaining cross sensitivities were found to be a function of the total particle load on the filter. The large variation between the response to absorbing aerosol particles for different types of instruments indicates that current correction functions for absorption photometers are not adequate.JRC.DDG.H.2-Climate change and air qualit
    corecore