249 research outputs found

    Model for screening of resonant magnetic perturbations by plasma in a realistic tokamak geometry and its impact on divertor strike points

    Full text link
    This work addresses the question of the relation between strike-point splitting and magnetic stochasticity at the edge of a poloidally diverted tokamak in the presence of externally imposed magnetic perturbations. More specifically, ad-hoc helical current sheets are introduced in order to mimic a hypothetical screening of the external resonant magnetic perturbations by the plasma. These current sheets, which suppress magnetic islands, are found to reduce the amount of splitting expected at the target, which suggests that screening effects should be observable experimentally. Multiple screening current sheets reinforce each other, i.e. less current relative to the case of only one current sheet is required to screen the perturbation.Comment: Accepted in the Proceedings of the 19th International Conference on Plasma Surface Interactions, to be published in Journal of Nuclear Materials. Version 2: minor formatting and text improvements, more results mentioned in the conclusion and abstrac

    Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    Get PDF
    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR

    Relationship of edge localized mode burst times with divertor flux loop signal phase in JET

    Get PDF
    A phase relationship is identified between sequential edge localized modes (ELMs) occurrence times in a set of H-mode tokamak plasmas to the voltage measured in full flux azimuthal loops in the divertor region. We focus on plasmas in the Joint European Torus where a steady H-mode is sustained over several seconds, during which ELMs are observed in the Be II emission at the divertor. The ELMs analysed arise from intrinsic ELMing, in that there is no deliberate intent to control the ELMing process by external means. We use ELM timings derived from the Be II signal to perform direct time domain analysis of the full flux loop VLD2 and VLD3 signals, which provide a high cadence global measurement proportional to the voltage induced by changes in poloidal magnetic flux. Specifically, we examine how the time interval between pairs of successive ELMs is linked to the time-evolving phase of the full flux loop signals. Each ELM produces a clear early pulse in the full flux loop signals, whose peak time is used to condition our analysis. The arrival time of the following ELM, relative to this pulse, is found to fall into one of two categories: (i) prompt ELMs, which are directly paced by the initial response seen in the flux loop signals; and (ii) all other ELMs, which occur after the initial response of the full flux loop signals has decayed in amplitude. The times at which ELMs in category (ii) occur, relative to the first ELM of the pair, are clustered at times when the instantaneous phase of the full flux loop signal is close to its value at the time of the first ELM

    Overcoming difficult conversations in clinical supervision

    No full text
    Brett Williams,1 Christine King,1 Tanya Edlington,21Department of Community Emergency Health and Paramedic Practice, Monash University, Franskton, VIC, 2The Conversation Clinic Pty Ltd, Melbourne, VIC, Australia Background: Clinical supervisors are responsible for managing many facets of clinical learning and face a range of challenges when the need for "difficult" conversations arises, including the need to manage conflict and relationships. Methods: Spotlight on Conversations Workshop was developed to improve the capacity of clinical supervisors to engage in difficult conversations. They were designed to challenge the mindset of clinical supervisors about difficult conversations with students, the consequences of avoiding difficult conversations, and to offer activities for practicing difficult conversations. Preworkshop, postworkshop, and 4-month follow-up evaluations assessed improvements in knowledge, intent to improve, and confidence along with workshop satisfaction. Results: Nine workshops were delivered in a range of locations across Victoria, Australia, involving a total of 117 clinical supervisors. Preworkshop evaluations illustrated that more than half of the participants had avoided up to two difficult conversations in the last month in their workplace. Postworkshop evaluation at 4 months showed very high levels of satisfaction with the workshop's relevancy, content, and training, as well as participants' intention to apply knowledge and skills. Also shown were significant changes in participants' confidence to have difficult conversations not only with students but also with other peers and colleagues. In follow-up in-depth interviews with 20 of the 117 participants, 75% said they had made definite changes in their practice because of what they learned in the workshop and another 10% said they would make changes to their practice, but had not had the opportunity yet to do so. Conclusion: We conclude that the Spotlight on Conversations Workshop can improve the clinical supervisor–student relationship as well as build general difficult conversation capacity for a range of stakeholders in clinical settings. Keywords: clinical, education, supervision, communicatio

    Poloidal polarimeter system for current density measurements in ITER

    Get PDF
    The polarimeter system for ITER features 10 viewing chords covering almost the full poloidal cross section of the plasma in a fan-like arrangement. The 10 laser beams all enter the plasma via 150 mm diam penetrations through the diagnostic plug at the low-field side. Small retroreflectors at the high-field side mirror the laser beams back towards the penetrations at the low-field side. Extensive feasibility calculations have led to the conclusion that the optimum wavelength for the polarimeter is around 100 mu m. At this wavelength counterproductive effects like refraction and electron cyclotron absorption are negligibly small. However, the anticipated Faraday rotation angles are still very large, such that several important plasma parameters can be measured within the requirements set by the ITER team. In this article the status of the conceptual design of the polarimeter system for ITER will be presented. (C) 1999 American Institute of Physics. [S0034-6748(99)63801-1]

    Manufacturing and commissioning of the new ex-vessel magnetic diagnostics system for JET

    No full text
    A new system of magnetic probes was installed during the 2005 shutdown and was commissioned during the 2005/2006 restart phase of JET. The system is made of traditional pick-up coils and Hall sensors, all located outside the vessel. Direct \ufb01eld measurements from Hall sensors are used to correct the drift of the integrators of the pick-up coils signals. This feature will be crucial for future ITER-like devices, where long-lasting \ufb02at top phases are expected, in a high neutron yield and a high temperature environment. After a general overview of the system, the paper describes the major manufacturing and installation issues, including the construction of the supports and probes as well as the acceptance tests before and after installation. The functional commissioning of the system includes the integration of the new signals in the JET Data Acquisition System and the analysis of several discharges with and without plasma. The critical aspects of the assessment of the reliability of the signals are shown and commented on

    Poloidal polarimeter system for current density measurements in ITER

    No full text
    The polarimeter system for ITER features 10 viewing chords covering almost the full poloidal cross section of the plasma in a fan-like arrangement. The 10 laser beams all enter the plasma via 150 mm diam penetrations through the diagnostic plug at the low-field side. Small retroreflectors at the high-field side mirror the laser beams back towards the penetrations at the low-field side. Extensive feasibility calculations have led to the conclusion that the optimum wavelength for the polarimeter is around 100 mu m. At this wavelength counterproductive effects like refraction and electron cyclotron absorption are negligibly small. However, the anticipated Faraday rotation angles are still very large, such that several important plasma parameters can be measured within the requirements set by the ITER team. In this article the status of the conceptual design of the polarimeter system for ITER will be presented. (C) 1999 American Institute of Physics. [S0034-6748(99)63801-1]
    corecore