232 research outputs found
Associates of Cardiopulmonary Arrest in the Perihemodialytic Period
Cardiopulmonary arrest during and proximate to hemodialysis is rare but highly fatal. Studies have examined peridialytic sudden cardiac event risk factors, but no study has considered associates of cardiopulmonary arrests (fatal and nonfatal events including cardiac and respiratory causes). This study was designed to elucidate patient and procedural factors associated with peridialytic cardiopulmonary arrest. Data for this case-control study were taken from the hemodialysis population at Fresenius Medical Care, North America. 924 in-center cardiopulmonary events (cases) and 75,538 controls were identified. Cases and controls were 1 : 5 matched on age, sex, race, and diabetes. Predictors of cardiopulmonary arrest were considered for logistic model inclusion. Missed treatments due to hospitalization, lower body mass, coronary artery disease, heart failure, lower albumin and hemoglobin, lower dialysate potassium, higher serum calcium, greater erythropoietin stimulating agent dose, and normalized protein catabolic rate (J-shaped) were associated with peridialytic cardiopulmonary arrest. Of these, lower albumin, hemoglobin, and body mass index; higher erythropoietin stimulating agent dose; and greater missed sessions had the strongest associations with outcome. Patient health markers and procedural factors are associated with peridialytic cardiopulmonary arrest. In addition to optimizing nutritional status, it may be prudent to limit exposure to low dialysate potassium (<2 K bath) and to use the lowest effective erythropoietin stimulating agent dose
Associates of Cardiopulmonary Arrest in the Perihemodialytic Period
properly cited. Cardiopulmonary arrest during and proximate to hemodialysis is rare but highly fatal. Studies have examined peridialytic sudden cardiac event risk factors, but no study has considered associates of cardiopulmonary arrests (fatal and nonfatal events including cardiac and respiratory causes). This study was designed to elucidate patient and procedural factors associated with peridialytic cardiopulmonary arrest. Data for this case-control study were taken from the hemodialysis population at Fresenius Medical Care, North America. 924 in-center cardiopulmonary events (cases) and 75,538 controls were identified. Cases and controls were 1 : 5 matched on age, sex, race, and diabetes. Predictors of cardiopulmonary arrest were considered for logistic model inclusion. Missed treatments due to hospitalization, lower body mass, coronary artery disease, heart failure, lower albumin and hemoglobin, lower dialysate potassium, higher serum calcium, greater erythropoietin stimulating agent dose, and normalized protein catabolic rate (J-shaped) were associated with peridialytic cardiopulmonary arrest. Of these, lower albumin, hemoglobin, and body mass index; higher erythropoietin stimulating agent dose; and greater missed sessions had the strongest associations with outcome. Patient health markers and procedural factors are associated with peridialytic cardiopulmonary arrest. In addition to optimizing nutritional status, it may be prudent to limit exposure to low dialysate potassium (<2 K bath) and to use the lowest effective erythropoietin stimulating agent dose
Optimal and continuous anaemia control in a cohort of dialysis patients in Switzerland
BACKGROUND: Guidelines for the management of anaemia in patients with chronic kidney disease (CKD) recommend a minimal haemoglobin (Hb) target of 11 g/dL. Recent surveys indicate that this requirement is not met in many patients in Europe. In most studies, Hb is only assessed over a short-term period. The aim of this study was to examine the control of anaemia over a continuous long-term period in Switzerland. METHODS: A prospective multi-centre observational study was conducted in dialysed patients treated with recombinant human epoetin (EPO) beta, over a one-year follow-up period, with monthly assessments of anaemia parameters. RESULTS: Three hundred and fifty patients from 27 centres, representing 14% of the dialysis population in Switzerland, were included. Mean Hb was 11.9 +/- 1.0 g/dL, and remained stable over time. Eighty-five % of the patients achieved mean Hb &gt;or= 11 g/dL. Mean EPO dose was 155 +/- 118 IU/kg/week, being delivered mostly by subcutaneous route (64-71%). Mean serum ferritin and transferrin saturation were 435 +/- 253 microg/L and 30 +/- 11%, respectively. At month 12, adequate iron stores were found in 72.5% of patients, whereas absolute and functional iron deficiencies were observed in only 5.1% and 17.8%, respectively. Multivariate analysis showed that diabetes unexpectedly influenced Hb towards higher levels (12.1 +/- 0.9 g/dL; p = 0.02). One year survival was significantly higher in patients with Hb &gt;or= 11 g/dL than in those with Hb &lt;11 g/dL (19.7% vs 7.3%, p = 0.006). CONCLUSION: In comparison to European studies of reference, this survey shows a remarkable and continuous control of anaemia in Swiss dialysis centres. These results were reached through moderately high EPO doses, mostly given subcutaneously, and careful iron therapy management
Serum iPTH, calcium and phosphate, and the risk of mortality in a European haemodialysis population
Background. A number of US observational studies reported an increased mortality risk with higher intact parathyroid hormone (iPTH), calcium and/or phosphate. The existence of such a link in a European haemodialysis population was explored as part of the Analysing Data, Recognising Excellence and Optimising Outcomes (ARO) Chronic Kidney Disease (CKD) Research Initiative
Association of dialysis facility-level hemoglobin measurement and erythropoiesis-stimulating agent dose adjustment frequencies with dialysis facility-level hemoglobin variation: a retrospective analysis
<p>Abstract</p> <p>Background</p> <p>A key goal of anemia management in dialysis patients is to maintain patients' hemoglobin (Hb) levels consistently within a target range. Our aim in this study was to assess the association of facility-level practice patterns representing Hb measurement and erythropoiesis-stimulating agent (ESA) dose adjustment frequencies with facility-level Hb variation.</p> <p>Methods</p> <p>This was a retrospective observational database analysis of patients in dialysis facilities affiliated with large dialysis organizations as of July 01, 2006, covering a follow-up period from July 01, 2006 to June 30, 2009. A total of 2,763 facilities representing 436,442 unique patients were included. The predictors evaluated were facility-level Hb measurement and ESA dose adjustment frequencies, and the outcome measured was facility-level Hb variation.</p> <p>Results</p> <p>First to 99th percentile ranges for facility-level Hb measurement and ESA dose adjustment frequencies were approximately once per month to once per week and approximately once per 3 months to once per 3 weeks, respectively. Facility-level Hb measurement and ESA dose adjustment frequencies were inversely associated with Hb variation. Modeling results suggested that a more frequent Hb measurement (once per week rather than once per month) was associated with approximately 7% to 9% and 6% to 8% gains in the proportion of patients with Hb levels within a ±1 and ±2 g/dL range around the mean, respectively. Similarly, more frequent ESA dose adjustment (once per 2 weeks rather than once per 3 months) was associated with approximately 6% to 9% and 5% to 7% gains in the proportion of patients in these respective Hb ranges.</p> <p>Conclusions</p> <p>Frequent Hb measurements and timely ESA dose adjustments in dialysis patients are associated with lower facility-level Hb variation and an increase in proportion of patients within ±1 and ±2 g/dL ranges around the facility-level Hb mean.</p
Maintaining over time Clinical Performance targets on Anaemia correction in unselected population on chronic dialysis at 20 Italian Centres. Data from a retrospective study for a Clinical Audit
<p>Abstract</p> <p>Background</p> <p>The Italian and European Best Practice Guidelines (EBPG) recommend a target haemoglobin value greater than 11 g/dl in most patients with Chronic Kidney Diseases. However, it is still difficult to maintain these values at a steady rate. Thus, the main aim of the study was to evaluate, throughout 2005, how many patients steadily maintained the performance targets related to anaemia treatment.</p> <p>Methods</p> <p>The survey was conducted on 3283 patients on haemodialysis (HD) and peritoneal dialysis (PD) at 20 Italian dialysis centres. 540 patients were randomly selected; each centre provided a statistically significant sample proportional to its total number of patients. Maintenance of the following target levels was assessed over time: Haemoglobin (HB) 11-12 gr/dl; Iron: 60-160 mcg/dl; Ferritin: 30-400 mcg/l; Transferrin: 200-360 mg/dl; Transferrin saturation percentage (TSAT %):> 25 <50; Dialysis doses (KT/V): >1.2 <2.0 for non-diabetic HD patients; >1.5 <2.2 for diabetic HD patients; DP: >1.8 <2.5.</p> <p>Outcome included:</p> <p indent="1">1- Percentage of target maintenance for each parameter.</p> <p indent="1">2- Erythropoietin dose in relation to dialysis techniques, presence of cancer or myeloma, diabetic status, Vitamin B therapy.</p> <p indent="1">3- Erythropoietin dose (International Units/kg/week) (IU/kg/wk) depending on: haemoglobin values, hospitalization of more than 3 days.</p> <p>Results</p> <p>Mean age was 65.1; mean haemoglobin concentration over the whole population was 11.3 gr/dl (Standard Deviation (SD): 0.91). The clinical performance targets were maintained over time as follows: HB: 4.3% (Mean 11.43 gr/dl) (SD: 0.42); Ferritin: 71.1% (Mean: 250.23 mcg/L (SD:104.07); Iron: 95.0% (Mean 59.79 mcg/dl)(SD:16.76); Transferrin: 44.8% (Mean 216.83 mg/dl) (SD: 19,50); TSAT %: in 8.4% (Mean: 34.33% (SD: 6.56); HD KT/V: 61.0% (Mean:1.46) (SD: 0.7); PD KT/V:31.4% (Mean: 2.10) (SD: 0.02). The average weekly dose of Erythropoietin (IU/Kg/Wk) was significantly lower for the peritoneal dialysis technique; the higher haemoglobin values, the lower the Erythropoietin dose (IU/Kg/Wk).</p> <p>Conclusion</p> <p>A very low percentage of patients maintained haemoglobin target values over time. We need to identify precise criteria to evaluate the stability over time of clinical performance targets proposed by the guidelines.</p
- …