164 research outputs found
Brightness temperature and attenuation diversity statistics at 20.6 and 31.65 GHz for the Colorado Research Network
A limited network of four dual-channel microwave radiometers, with frequencies of 20.6 and 31.65 GHz, was operated in the front range of eastern Colorado from 1985 to 1988. Data, from November 1987 through October 1988 are analyzed to determine both single-station and joint-station brightness temperature and attenuation statistics. Only zenith observations were made. The spatial separations of the stations varied from 50 km to 190 km. Before the statistics were developed, the data were screened by rigorous quality control methods. One such method, that of 20.6 vs. 31.65 GHz scatter plots, is analyzed in detail, and comparisons are made of measured vs calculated data. At 20.6 and 31.65 GHz, vertical attenuations of 5 and 8 dB are exceeded 0.01 percent of the time. For these four stations and at the same 0.01 percent level, diversity gains from 6 to 8 dB are possible with the 50 to 190 km separations
On the Inversion of Light Scattering Data into Information on Aerosol Properties
The Backus-Gilbert inversion technique was applied to scattering data and calculated examples were given to ascertain its ability to recover the aerosol properties with no a-priori assumptions. In order to cheque this inversion procedure as well as other techniques (such as Daves' and Herman's et al.), a controlled experiment was performed. The experiment dealt with spherical particles the Mie scattering curves of which was measured by use of a dye-laser. These curves were used to accurately determine the refractive index of the particles. Mixtures of three different known sizes were then prepared and the scattering intensity vs. wavelength was measured at 90 deg scattering angle. The mixtures contained also various known relative concentrations of the three sizes. The analysis of the measured results will be shown and discussed
Radiometric observations of atmospheric attenuation at 20.6 and 31.65 GHz: The Wave Propagation Laboratory data base
The National Oceanic and Atmospheric Administration (NOAA) Wave Propagation Laboratory (WPL) presently operates five dual-channel microwave radiometers, one triple-channel microwave radiometer, and one six-channel microwave radiometer. The dual-channel radiometers operate at frequencies of 20.6 or 23.87 GHz and 31.4 or 31.65 GHz. The triple-channel radiometer operates at 20.6, 31.65, and 90.0 GHz. The six-channel radiometer operates at frequencies of 20.6, 31.65, 52.85, 53.85, 55.45, and 58.8 GHz. Recent brightness temperature measurements and attenuation values from some of the above radiometers are presented. These radiometric measurements, taken in different locations throughout the world, have given WPL a diverse set of measurements under a variety of atmospheric conditions. We propose to do a more complete attenuation analysis on these measurements in the future. In addition, a new spinning reflector was installed recently for the dual-channel radiometer at the Platteville, Colorado site. This reflector will extend our measurement capabilities during precipating conditions. Locating the three-channel and portable dual-channel radiometers at or near Greeley, Colorado to support the Advanced Communications Technology Satellite (ACTS) program is discussed
Atmospheric Phase Correction Using Total Power Radiometry at the Submillimeter Array
Phase noise caused by an inhomogeneous, time-variable water vapor
distribution in our atmosphere reduces the angular resolution, visibility
amplitude and coherence time of millimeter and submillimeter wavelength
interferometers. We present early results from our total power radiometry phase
correction experiment carried out with the Submillimeter Array on Mauna Kea.
From accurate measurements of the atmospheric emission along the lines of
sight of two elements of the array, we estimated the differential atmospheric
electrical path between them. In one test, presented here, the phase correction
technique reduced the rms phase noise at 230 GHz from 72\degr to 27\degr
over a 20 minute period with a 2.5 second integration time. This corresponds to
a residual differential electrical path of 98 m, or 15 m of
precipitable water vapor, and raises the coherence in the 20 minute period from
0.45 to 0.9.Comment: Accepted for publication in the SMA Special Volume of the ApJ Letters
(9 pages of text, 3 figures
Self-avoiding fractional Brownian motion - The Edwards model
In this work we extend Varadhan's construction of the Edwards polymer model
to the case of fractional Brownian motions in , for any dimension , with arbitrary Hurst parameters .Comment: 14 page
Recommended from our members
PROGRESS REPORT OF FY 2004 ACTIVITIES: IMPROVED WATER VAPOR AND CLOUD RETRIEVALS AT THE NSA/AAO
The basic goals of the research are to develop and test algorithms and deploy instruments that improve measurements of water vapor, cloud liquid, and cloud coverage, with a focus on the Arctic conditions of cold temperatures and low concentrations of water vapor. The importance of accurate measurements of column amounts of water vapor and cloud liquid has been well documented by scientists within the Atmospheric Radiation Measurement Program. Although several technologies have been investigated to measure these column amounts, microwave radiometers (MWR) have been used operationally by the ARM program for passive retrievals of these quantities: precipitable water vapor (PWV) and integrated water liquid (IWL). The technology of PWV and IWL retrievals has advanced steadily since the basic 2-channel MWR was first deployed at ARM CART sites Important advances are the development and refinement of the tipcal calibration method [1,2], and improvement of forward model radiative transfer algorithms [3,4]. However, the concern still remains that current instruments deployed by ARM may be inadequate to measure low amounts of PWV and IWL. In the case of water vapor, this is especially important because of the possibility of scaling and/or quality control of radiosondes by the water amount. Extremely dry conditions, with PWV less than 3 mm, commonly occur in Polar Regions during the winter months. Accurate measurements of the PWV during such dry conditions are needed to improve our understanding of the regional radiation energy budgets. The results of a 1999 experiment conducted at the ARM North Slope of Alaska/Adjacent Arctic Ocean (NSA/AAO) site during March of 1999 [5] have shown that the strength associated with the 183 GHz water vapor absorption line makes radiometry in this frequency regime suitable for measuring low amounts of PWV. As a portion of our research, we conducted another millimeter wave radiometric experiment at the NSA/AAO in March-April 2004. This experiment relied heavily on our experiences of the 1999 experiment. Particular attention was paid to issues of radiometric calibration and radiosonde intercomparisons. Our theoretical and experimental work also supplements efforts by industry (F. Solheim, Private Communication) to develop sub-millimeter radiometers for ARM deployment. In addition to quantitative improvement of water vapor measurements at cold temperature, the impact of adding millimeter-wave window channels to improve the sensitivity to arctic clouds was studied. We also deployed an Infrared Cloud Imager (ICI) during this experiment, both for measuring continuous day-night statistics of the study of cloud coverage and identifying conditions suitable for tipcal analysis. This system provided the first capability of determining spatial cloud statistics continuously in both day and night at the NSA site and has been used to demonstrate that biases exist in inferring cloud statistics from either zenith-pointing active sensors (lidars or radars) or sky imagers that rely on scattered sunlight in daytime and star maps at night [6]
Critical Exponents, Hyperscaling and Universal Amplitude Ratios for Two- and Three-Dimensional Self-Avoiding Walks
We make a high-precision Monte Carlo study of two- and three-dimensional
self-avoiding walks (SAWs) of length up to 80000 steps, using the pivot
algorithm and the Karp-Luby algorithm. We study the critical exponents
and as well as several universal amplitude ratios; in
particular, we make an extremely sensitive test of the hyperscaling relation
. In two dimensions, we confirm the predicted
exponent and the hyperscaling relation; we estimate the universal
ratios , and (68\% confidence
limits). In three dimensions, we estimate with a
correction-to-scaling exponent (subjective 68\%
confidence limits). This value for agrees excellently with the
field-theoretic renormalization-group prediction, but there is some discrepancy
for . Earlier Monte Carlo estimates of , which were , are now seen to be biased by corrections to scaling. We estimate the
universal ratios and ; since , hyperscaling holds. The approach to
is from above, contrary to the prediction of the two-parameter
renormalization-group theory. We critically reexamine this theory, and explain
where the error lies.Comment: 87 pages including 12 figures, 1029558 bytes Postscript
(NYU-TH-94/09/01
Sequence-specific antimicrobials using efficiently delivered RNA-guided nucleases
Current antibiotics tend to be broad spectrum, leading to indiscriminate killing of commensal bacteria and accelerated evolution of drug resistance. Here, we use CRISPR-Cas technology to create antimicrobials whose spectrum of activity is chosen by design. RNA-guided nucleases (RGNs) targeting specific DNA sequences are delivered efficiently to microbial populations using bacteriophage or bacteria carrying plasmids transmissible by conjugation. The DNA targets of RGNs can be undesirable genes or polymorphisms, including antibiotic resistance and virulence determinants in carbapenem-resistant Enterobacteriaceae and enterohemorrhagic Escherichia coli. Delivery of RGNs significantly improves survival in a Galleria mellonella infection model. We also show that RGNs enable modulation of complex bacterial populations by selective knockdown of targeted strains based on genetic signatures. RGNs constitute a class of highly discriminatory, customizable antimicrobials that enact selective pressure at the DNA level to reduce the prevalence of undesired genes, minimize off-target effects and enable programmable remodeling of microbiota.National Institutes of Health (U.S.) (New Innovator Award 1DP2OD008435)National Centers for Systems Biology (U.S.) (Grant 1P50GM098792)United States. Defense Threat Reduction Agency (HDTRA1-14-1-0007)Massachusetts Institute of Technology. Institute for Soldier Nanotechnologies (W911NF13D0001)National Institute of General Medical Sciences (U.S.) (Interdepartmental Biotechnology Training Program 5T32 GM008334)Fonds de la recherche en sante du Quebec (Master's Training Award
Is food addiction a predictor of treatment outcome among patients with eating disorder?
ObjectivesThe study aimed to examine whether food addiction (FA) was associated with greater severity in both binge eating disorders (BED) and bulimia nervosa and, therefore, to determine if FA was predictive of treatment outcome.MethodSeventy-one adult patients with bulimia nervosa and BED (42 and 29, respectively) participated in the study. FA was assessed by means of the Yale Food Addiction Scale.ResultsThe results confirmed a high prevalence of FA in patients with binge disorders (around 87%) and also its association with a greater severity of the disorder (i.e., related to an increased eating psychopathology and greater frequency of binge eating episodes). Although FA did not appear as a predictor of treatment outcome in general terms, when the diagnostic subtypes were considered separately, FA was associated with poor prognosis in the BED group. In this vein, FA appeared as a mediator in the relationship between ED severity and treatment outcome.DiscussionsOur findings suggest that FA may act as an indicator of ED severity, and it would be a predictor of treatment outcome in BED but not in BN.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/152018/1/erv2705.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/152018/2/erv2705_am.pd
- âŠ