468 research outputs found
Neutron Measurements for Radiation Protection in Low Earth Orbit - History and Future
The neutron environment inside spacecraft has been of interest from a scientific and radiation protection perspective since early in the history of manned spaceflight. With 1:.1e exception of a few missions which carried plutonium-fueled radioisotope thermoelectric generators, all of the neutrons inside the spacecraft are secondary radiations resulting from interactions of high-energy charged particles with nuclei in the Earth's atmosphere, spacecraft structural materials, and the astronaut's own bodies. Although of great interest, definitive measurements of the spacecraft neutron field have been difficult due to the wide particle energy range and the limited available volume and power for traditional techniques involving Bonner spheres. A multitude of measurements, however, have been made of the neutron environment inside spacecraft. The majority of measurements were made using passive techniques including metal activation fo ils, fission foils, nuclear photoemulsions, plastic track detectors, and thermoluminescent detectors. Active measurements have utilized proton recoil spectrometers (stilbene), Bonner Spheres eRe proportional counter based), and LiI(Eu)phoswich scintillation detectors. For the International Space Station (ISS), only the plastic track! thermoluminescent detectors are used with any regularity. A monitoring program utilizing a set of active Bonner spheres was carried out in the ISS Lab module from March - December 200l. These measurements provide a very limited look at the crew neutron exposure, both in time coverage and neutron energy coverage. A review of the currently published data from past flights will be made and compared with the more recent results from the ISS. Future measurement efforts using currently available techniques and those in development will be also discussed
Accelerating inference for stochastic kinetic models
Stochastic kinetic models (SKMs) are increasingly used to account for the
inherent stochasticity exhibited by interacting populations of species in areas
such as epidemiology, population ecology and systems biology. Species numbers
are modelled using a continuous-time stochastic process, and, depending on the
application area of interest, this will typically take the form of a Markov
jump process or an It\^o diffusion process. Widespread use of these models is
typically precluded by their computational complexity. In particular,
performing exact fully Bayesian inference in either modelling framework is
challenging due to the intractability of the observed data likelihood,
necessitating the use of computationally intensive techniques such as particle
Markov chain Monte Carlo (particle MCMC). It is proposed to increase the
computational and statistical efficiency of this approach by leveraging the
tractability of an inexpensive surrogate derived directly from either the jump
or diffusion process. The surrogate is used in three ways: in the design of a
gradient-based parameter proposal, to construct an appropriate bridge and in
the first stage of a delayed-acceptance step. The resulting approach, which
exactly targets the posterior of interest, offers substantial gains in
efficiency over a standard particle MCMC implementation.Comment: 29 page
Inverse Ac Josephson Effect at Terahertz Frequencies
The inverse ac Josephson effect occurs when a Josephson junction driven by a microwave source of frequency f produces constant‐voltage steps at integer multiples of h f/2e. For low‐leakage current hysteretic junctions driven at microwave frequencies below about 100 GHz, some of these steps can cross the zero dc bias current axis. These zero‐crossing steps allow modern series array voltage standards to operate without individually biasing the junctions in the array. We reexamine the theory behind these steps and show that they can exist at frequencies much higher than thought previously. The Riedel singularity in the supercurrent response allows this effect to exist even up to terahertz frequencies. We describe a set of analytical calculations which provide limits on the amount of rounding of the Riedel peak which can be permitted while still allowing these zero‐crossing steps to occur. We also discuss practical considerations such as microwave power levels required and parameters for device fabrication. This analysis is supported by numerical frequency‐domain computations and time‐domain simulations for a number of realistic I‐V curves with rounded Riedel singularities and with quasiparticle subgap leakage currents
GCR access to the Moon as measured by the CRaTER instrument on LRO
[1] Recent modeling efforts have yielded varying and conflicting results regarding the possibility that Earth\u27s magnetosphere is able to shield energetic particles of \u3e10 MeV at lunar distances. This population of particles consists of galactic cosmic rays as well as energetic particles that are accelerated by solar flares and coronal mass ejections. The Cosmic Ray Telescope for the Effects of Radiation (CRaTER) onboard the Lunar Reconnaissance Orbiter is in orbit about the Moon and is thus able to directly test these modeling results. Over the course of a month, CRaTER samples the upstream solar wind as well as various regions of Earth\u27s magnetotail. CRaTER data from multiple lunations demonstrate that Earth\u27s magnetosphere at lunar distances produces no measurable influence on energetic particle flux, even at the lowest energies (\u3e14 MeV protons) where any effect should be maximized. For particles with energies of 14–30 MeV, we calculate an upper limit (determined by counting statistics) on the amount of shielding caused by the magnetosphere of 1.7%. The high energy channel (\u3e500 MeV) provides an upper limit of 3.2%
Exercise in the management of knee and hip osteoarthritis
Purpose of review This review focuses on studies published during July 2001 to August 2017 of exercise as an intervention in knee and hip osteoarthritis, including its influence on an array of patient outcomes. Recent findings Studies continue to illustrate the efficacy of exercise in treating and managing osteoarthritis, with current literature more focused on the knee compared with the hip joint. Both traditional (e.g. strength, aerobic, flexibility) and more nontraditional (e.g. yoga, Tai Chi, aquatic) training modes improve patient outcomes related to joint symptoms, mobility, quality of life, psychological health, musculoskeletal properties, body composition, sleep, and fatigue. Exercise that is adequately dosed (e.g. frequency, intensity) and progressive in nature demonstrated the greatest improvements in patient outcomes. Supervised, partially supervised, and nonsupervised interventions can be successful in the treatment of osteoarthritis, but patient preference regarding level of supervision and mode of exercise may be key predictors in exercise adherence and degree of outcome improvement. A topic of increasing interest in osteoarthritis is the supplementary role of behavior training in exercise interventions. Summary Osteoarthritis is a complex, multifactorial disease that can be successfully managed and treated through exercise, with minimal risk for negative consequences. However, to have greatest impact, appropriate exercise prescription is needed. Efforts to achieve correct exercise doses and mitigate patient nonadherence are needed to lessen the lifelong burden of osteoarthritis
The radiation environment near the lunar surface: CRaTER observations and Geant4 simulations
[1] At the start of the Lunar Reconnaissance Orbiter mission in 2009, its Cosmic Ray Telescope for the Effects of Radiation instrument measured the radiation environment near the Moon during the recent deep solar minimum, when galactic cosmic rays (GCRs) were at the highest level observed during the space age. We present observations that show the combined effects of GCR primaries, secondary particles (“albedo”) created by the interaction of GCRs with the lunar surface, and the interactions of these particles in the shielding material overlying the silicon solid-state detectors of the Cosmic Ray Telescope for the Effects of Radiation. We use Geant4 to model the energy and angular distribution of the albedo particles, and to model the response of the sensor to the various particle species reaching the 50 kilometer altitude of the Lunar Reconnaissance Orbiter. Using simulations to gain insight into the observations, we are able to present preliminary energy-deposit spectra for evaluation of the radiation environment\u27s effects on other sensitive materials, whether biological or electronic, that would be exposed to a similar near-lunar environment
Cross-sectional associations between variations in ankle shape by statistical shape modeling, injury history, and race : the Johnston County Osteoarthritis Project
Rheumatology Research Foundation Medical Student Preceptorship Award (Lateef/Nelson), NIAMS K23 AR061406 (Nelson); NIH/NIAMS P60AR064166 and U01DP003206 (Jordan/Renner), NIH/NIAMS R01AR067743 (Golightly). The funders had no role in study design; collection, analysis, or interpretation of data; writing the manuscript or the decision to submit for publication.Peer reviewedPublisher PD
New measurements of total ionizing dose in the lunar environment
[1] We report new measurements of solar minimum ionizing radiation dose at the Moon onboard the Lunar Reconnaissance Orbiter (LRO) from June 2009 through May 2010. The Cosmic Ray Telescope for the Effects of Radiation (CRaTER) instrument on LRO houses a compact and highly precise microdosimeter whose design allows measurements of dose rates below 1 micro-Rad per second in silicon achieved with minimal resources (20 g, ∼250 milliwatts, and ∼3 bits/second). We envision the use of such a small yet accurate dosimeter in many future spaceflight applications where volume, mass, and power are highly constrained. As this was the first operation of the microdosimeter in a space environment, the goal of this study is to verify its response by using simultaneous measurements of the galactic cosmic ray ionizing environment at LRO, at L1, and with other concurrent dosimeter measurements and model predictions. The microdosimeter measured the same short timescale modulations in the galactic cosmic rays as the other independent measurements, thus verifying its response to a known source of minimum-ionizing particles. The total dose for the LRO mission over the first 333 days was only 12.2 Rads behind ∼130 mils of aluminum because of the delayed rise of solar activity in solar cycle 24 and the corresponding lack of intense solar energetic particle events. The dose rate in a 50 km lunar orbit was about 30 percent lower than the interplanetary rate, as one would expect from lunar obstruction of the visible sky
The first cosmic ray albedo proton map of the Moon
[1] Neutrons emitted from the Moon are produced by the impact of galactic cosmic rays (GCRs) within the regolith. GCRs are high-energy particles capable of smashing atomic nuclei in the lunar regolith and producing a shower of energetic protons, neutrons and other subatomic particles. Secondary particles that are ejected out of the regolith become “albedo” particles. The neutron albedo has been used to study the hydrogen content of the lunar regolith, which motivates our study of albedo protons. In principle, the albedo protons should vary as a function of the input GCR source and possibly as a result of surface composition and properties. During the LRO mission, the total detection rate of albedo protons between 60 MeV and 150 MeV has been declining since 2009 in parallel with the decline in the galactic cosmic ray flux, which validates the concept of an albedo proton source. On the other hand, the average yield of albedo protons has been increasing as the galactic cosmic ray spectrum has been hardening, consistent with a disproportionately stronger modulation of lower energy GCRs as solar activity increases. We construct the first map of the normalized albedo proton emission rate from the lunar surface to look for any albedo variation that correlates with surface features. The map is consistent with a spatially uniform albedo proton yield to within statistical uncertainties
Radiation modeling in the Earth and Mars atmospheres using LRO/CRaTER with the EMMREM Module
Abstract We expand upon the efforts of Joyce et al. (2013), who computed the modulation potential at the Moon using measurements from the Cosmic Ray Telescope for the Effects of Radiation (CRaTER) instrument on the Lunar Reconnaissance Orbiter (LRO) spacecraft along with data products from the Earth-Moon-Mars Radiation Environment Module (EMMREM). Using the computed modulation potential, we calculate galactic cosmic ray (GCR) dose and dose equivalent rates in the Earth and Mars atmospheres for various altitudes over the course of the LRO mission. While we cannot validate these predictions by directly comparable measurement, we find that our results conform to expectations and are in good agreement with the nearest available measurements and therefore may be used as reasonable estimates for use in efforts in risk assessment in the planning of future space missions as well as in the study of GCRs. PREDICCS (Predictions of radiation from REleASE, EMMREM, and Data Incorporating the CRaTER, COSTEP, and other solar energetic particles measurements) is an online system designed to provide the scientific community with a comprehensive resource on the radiation environments of the inner heliosphere. The data products shown here will be incorporated into PREDICCS in order to further this effort and daily updates will be made available on the PREDICCS website (http://prediccs.sr.unh.edu). Key Points We model GCR dose and dose equivalent rates in Earth and Mars atmospheres Dose rates are in reasonable agreement with nearby measurements Data products will soon be made available on PREDICCS website
- …