126 research outputs found

    Fate Of Abstracts Published In The Proceedings Of The First Annual Perinatal Society Of Australia And New Zealand Congress In 1997

    Get PDF
    Objectives: To examine the fate of research presented at the first annual Perinatal Society of Australia and New Zealand (PSANZ) Congress in 1997, by determining: the rate of publication in peer-reviewed biomedical journals; publication rate by discipline; journals in which work was published; concordance for aims, conclusions, authors and number of study subjects; and time from presentation to publication. Methods: A MEDLINE search was conducted for any publication in a peer-reviewed journal resulting from a publishable abstract from the proceedings of the first annual PSANZ Congress in 1997. Searching was completed 42 months postcongress. The concordance of aims, conclusions, authors and number of subjects between abstract and published paper was determined. Results: There were 172 publishable abstracts in the proceedings of the PSANZ Congress in 1997, and 78 (45%) were published as 83 articles. Basic sciences had the highest publication rate (67%) and midwifery the lowest (20%). Articles were published in 41 journals, with one-third of the articles in three paediatric journals. There was a match with aims in 75%, and with conclusions in 65%. There were 47/77 with the same number of subjects, 20/77 with more and 10/77 with fewer. There were 22 articles with one author added, 12 had more than one author added, 11 had one author removed and five had more than one author removed. Median time-to-publication was 18 months (interquartile range 9-26 months). Conclusions: A publication rate of 45% is comparable to other conferences. Basic science and neonatology had the highest publication rates. There were considerable differences between abstract and published article in terms of aims, conclusions, number of subjects and authors

    An advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental model

    Get PDF
    BACKGROUND: The loss of perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be minimized both to prevent perfluorocarbon vapour entering the atmosphere and to re-use the recovered PFC liquid. Using a substantially modified design of our previously described condenser, we aimed to determine how much perfluorocarbon liquid could be recovered from gases containing PFC and water vapour, at concentrations found during partial liquid ventilation, and to determine if the amount recovered differed with background flow rate (at flow rates suitable for use in neonates). METHODS: The expiratory line of a standard ventilator circuit set-up was mimicked, with the addition of two condensers. Perfluorocarbon (30 mL of FC-77) and water vapour, at concentrations found during partial liquid ventilation, were passed through the circuit at a number of flow rates and the percentage recovery of the liquids measured. RESULTS: From 14.2 mL (47%) to 27.3 mL (91%) of the infused 30 mL of FC-77 was recovered at the flow rates studied. Significantly higher FC-77 recovery was obtained at lower flow rates (ANOVA with Bonferroni's multiple comparison test, p < 0.0001). As a percentage of the theoretical maximum recovery, 64 to 95% of the FC-77 was recovered. Statistically significantly less FC-77 was recovered at 5 Lmin(-1 )(ANOVA with Bonferroni's multiple comparison test, p < 0.0001). Amounts of perfluorocarbon vapour recovered were 47%, 50%, 81% and 91% at flow rates of 10, 5, 2 and 1 Lmin(-1), respectively. CONCLUSION: Using two condensers in series 47% to 91% of perfluorocarbon liquid can be recovered, from gases containing perfluorocarbon and water vapour, at concentrations found during partial liquid ventilation

    Developing an economic led approach to zero carbon housing design through integration and substitution of traditional building materials

    Get PDF
    Zero carbon homes have met with mixed reactions from key stakeholders within the housing and energy sectors, with many bespoke zero carbon designs being rejected as commercially unviable. This paper draws on research conducted with The University of Surrey and Zedfactory Architects to outline key factors which should be considered in order to facilitate the adoption of a more commercialised approach to zero carbon design. Key design criteria for zero carbon homes are outlined before presenting a housing model designed to provide the best balance between the financial, technical and social elements involved. The paper then demonstrates the importance of reducing the additional costs associated with zero carbon design through integrating energy efficiency and generation technologies into the building fabric; by substituting the use of traditional building materials with energy generating ones it is possible to create both an energy and economically efficient housing model. The proposed energy system adopts an integrated approach to the selection of space heating, water heating and ventilation technologies in order to create a design that is as user friendly as possible. By adopting this approach it is argued that it is possible to develop a model which does not require major changes in household behaviour patterns to work. The paper also highlights the importance of carefully balancing energy production and exportation to grid connected sources to develop a zero carbon home that can substantially reduce the financial burdens of rising energy costs

    Vortex Polarity Switching in Magnets with Surface Anisotropy

    Get PDF
    Vortex core reversal in magnetic particle is essentially influenced by a surface anisotropy. Under the action of a perpendicular static magnetic field the vortex core undergoes a shape deformationof pillow- or barrel-shaped type, depending on the type of the surface anisotropy. This deformation plays a key point in the switching mechanism: We predict that the vortex polarity switching is accompanied (i) by a linear singularity in case of Heisenberg magnet with bulk anisotropy only and (ii) by a point singularities in case of surface anisotropy or exchange anisotropy. We study in details the switching process using spin-lattice simulations and propose a simple analytical description using a wired core model, which provides an adequate description of the Bloch point statics, its dynamics and the Bloch point mediated switching process. Our analytical predictions are confirmed by spin-lattice simulations for Heisenberg magnet and micromagnetic simulations for nanomagnet with account of a dipolar interaction.Comment: 17 pages, 15 figure

    Increased Oxidative Burden Associated with Traffic Component of Ambient Particulate Matter at Roadside and Urban Background Schools Sites in London

    Get PDF
    As the incidence of respiratory and allergic symptoms has been reported to be increased in children attending schools in close proximity to busy roads, it was hypothesised that PM from roadside schools would display enhanced oxidative potential (OP). Two consecutive one-week air quality monitoring campaigns were conducted at seven school sampling sites, reflecting roadside and urban background in London. Chemical characteristics of size fractionated particulate matter (PM) samples were related to the capacity to drive biological oxidation reactions in a synthetic respiratory tract lining fluid. Contrary to hypothesised contrasts in particulate OP between school site types, no robust size-fractionated differences in OP were identified due high temporal variability in concentrations of PM components over the one-week sampling campaigns. For OP assessed both by ascorbate (OPAA m−3) and glutathione (OPGSH m−3) depletion, the highest OP per cubic metre of air was in the largest size fraction, PM1.9–10.2. However, when expressed per unit mass of particles OPAA µg−1 showed no significant dependence upon particle size, while OPGSH µg−1 had a tendency to increase with increasing particle size, paralleling increased concentrations of Fe, Ba and Cu. The two OP metrics were not significantly correlated with one another, suggesting that the glutathione and ascorbate depletion assays respond to different components of the particles. Ascorbate depletion per unit mass did not show the same dependence as for GSH and it is possible that other trace metals (Zn, Ni, V) or organic components which are enriched in the finer particle fractions, or the greater surface area of smaller particles, counter-balance the redox activity of Fe, Ba and Cu in the coarse particles. Further work with longer-term sampling and a larger suite of analytes is advised in order to better elucidate the determinants of oxidative potential, and to fuller explore the contrasts between site types.\ud \u

    Intracellular Spatial Localization Regulated by the Microtubule Network

    Get PDF
    The commonly recognized mechanisms for spatial regulation inside the cell are membrane-bounded compartmentalization and biochemical association with subcellular organelles. We use computational modeling to investigate another spatial regulation mechanism mediated by the microtubule network in the cell. Our results demonstrate that the mitotic spindle can impose strong sequestration and concentration effects on molecules with binding affinity for microtubules, especially dynein-directed cargoes. The model can recapitulate the essence of three experimental observations on distinct microtubule network morphologies: the sequestration of germ plasm components by the mitotic spindles in the Drosophila syncytial embryo, the asymmetric cell division initiated by the time delay in centrosome maturation in the Drosophila neuroblast, and the diffusional block between neighboring energids in the Drosophila syncytial embryo. Our model thus suggests that the cell cycle-dependent changes in the microtubule network are critical for achieving different spatial regulation effects. The microtubule network provides a spatially extensive docking platform for molecules and gives rise to a “structured cytoplasm”, in contrast to a free and fluid environment

    Intraaortic Balloon Pump Counterpulsation and Cerebral Autoregulation: an observational study

    Get PDF
    The use of Intra-aortic counterpulsation is a well established supportive therapy for patients in cardiac failure or after cardiac surgery. Blood pressure variations induced by counterpulsation are transmitted to the cerebral arteries, challenging cerebral autoregulatory mechanisms in order to maintain a stable cerebral blood flow. This study aims to assess the effects on cerebral autoregulation and variability of cerebral blood flow due to intra-aortic balloon pump and inflation ratio weaning

    The effect of perfluorocarbon vapour on the measurement of respiratory tidal volume during partial liquid ventilation

    Get PDF
    During partial liquid ventilation perfluorocarbon vapour is present in the exhaled gases. The volumes of these gases are measured by pneumotachometers. Error in measuring tidal volumes will give erroneous measurement of lung compliance during partial liquid ventilation. We aim to compare measured tidal volumes with and without perfluorocarbon vapour using tidal volumes suitable for use in neonates. Tidal volumes were produced with a 100 ml calibration syringe from 20 to 100 ml and with a calibrated Harvard rodent ventilator from 2.5 to 20 ml. Control tidal volumes were drawn from a humidifier chamber containing water vapour and the PFC tidal volumes were drawn from a humidifier chamber containing water and perfluorocarbon (FC-77) vapour. Tidal volumes were measured by a fixed orifice, target, differential pressure flowmeter (VenTrak) or a hot-wire anenometer (Bear Cub) placed between the calibration syringe or ventilator and the humidifier chamber. All tidal volumes measured with perfluorocarbon vapour were increased compared with control (ANOVA p < 0.001 and post t-test p < 0.0001). Measured tidal volume increased from 7 to 16% with the fixed orifice type flow-meter, and from 35 to 41% with the hot-wire type. In conclusion, perfluorocarbon vapour flowing through pneumotachometers gives falsely high tidal volume measurements. Calculation of lung compliance must take into account the effect of perfluorocarbon vapour on the measurement of tidal volume
    corecore