13 research outputs found

    Story Possibilities in Religious Studies at USD

    Get PDF
    The etiology of overweight and obesity is a mixture of genetic determinants, environmental factors, and health behaviors. Especially intra- and interpersonal inactive behaviors, here termed convenience, seems to play an important role. The objective was to develop and validate the Convenience Behavior Questionnaire (CBQ) to assess convenience-related items and their association with overweight and obesity in a large population. A sample of 1233 subjects aged 18–82 years from six population groups took part in a self-administered questionnaire. Test-retest reliability was estimated and the independent association between convenience-related items and overweight and obesity was investigated. Principal component analysis revealed three factors (avoidance behaviors, social interaction behaviors and domestic environmental factors) which explained 43.4% of the variance contributing to the CBQ. Cronbach's α ranged from 0.80–0.89. Test-retest reliability using intra-class correlation was acceptable ≥ 0.70. Forward stepwise logistic regression analysis, including gender, education level, age and TV viewing on weekends showed a positive relation of convenience behavior and overweight (OR: 1.40; 95% CI: 1.01–1.96; P = 0.048), while physical activity status was not significantly associated with overweight (OR: 1.09; 95% CI: 0.77–1.54; P = 0.629). The CBQ seems to be a reliable tool which considers non-traditional behaviors related to overweight development. Interestingly our findings revealed a better relationship between convenience-related behavior with overweight and obesity than the habitual physical activity score

    A Satellite Multiple-Beam Antenna for High-Rate Data Relays

    No full text
    This paper describes the concept and the development of key components of a novel multiple-beam antenna for satellite applications. The antenna is designed to be used in a transparent high-rate data relay system that links several LEO satellites to a single ground station via a GEO satellite. The proposed antenna is based on the concept of array-fed reflector. The antenna can track LEO satellites by switching between different subarrays of a bigger multifeed array using a reconfigurable switch matrix based on micro-electromechanical system (MEMS) switches. The radiation characteristic of the antenna is further improved by combining digital beamforming with the beam switching. To validate the proposed antenna concept and show its suitability for space applications a demonstrator has been built. Measurements of the antenna key components of the antenna and the demonstration system are given

    Comirnaty-Elicited and Convalescent Sera Recognize Different Spike Epitopes

    No full text
    Many of the approved SARS-CoV-2 vaccines are based on a stabilized variant of the spike protein. This raises the question of whether the immune response against the stabilized spike is identical to the immune response that is elicited by the native spike in the case of a SARS-CoV-2 infection. Using a peptide array-based approach, we analysed the binding of antibodies from Comirnaty-elicited, convalescent, and control sera to the peptides covering the spike protein. A total of 37 linear epitopes were identified. A total of 26 of these epitopes were almost exclusively recognized by the convalescent sera. Mapping these epitopes to the spike structures revealed that most of these 26 epitopes are masked in the pre-fusion structure. In particular, in the conserved central helix, three epitopes that are only exposed in the post-fusion conformation were identified. This indicates a higher spike-specific antibody diversity in convalescent sera. These differences could be relevant for the breadth of spike-specific immune response

    The Pharmaceutical Capping Process - Correlation between Residual Seal Force, Torque Moment, and Flip-off Removal Force

    No full text
    The majority of parenteral drug products are manufactured in glass vials with an elastomeric rubber stopper and a crimp cap. The vial sealing process is a critical process step during fill-and-finish operations, as it defines the seal quality of the final product. Different critical capping process parameters can affect rubber stopper defects, rubber stopper compression, container closure integrity, and also crimp cap quality. A sufficiently high force to remove the flip-off button prior to usage is required to ensure quality of the drug product unit by the flip-off button during storage, transportation, and until opening and use. Therefore, the final product is 100% visually inspected for lose or defective crimp caps, which is subjective as well as time- and labor-intensive. In this study, we sealed several container closure system configurations with different capping equipment settings (with corresponding residual seal force values) to investigate the torque moment required to turn the crimp cap. A correlation between torque moment and residual seal force has been established. The torque moment was found to be influenced by several parameters, including diameter of the vial head, type of rubber stopper (serum or lyophilized) and type of crimp cap (West(®) or Datwyler(®)). In addition, we measured the force required to remove the flip-off button of a sealed container closure system. The capping process had no influence on measured forces; however, it was possible to detect partially crimped vials. In conclusion, a controlled capping process with a defined target residual seal force range leads to a tight crimp cap on a sealed container closure system and can ensure product quality. LAY ABSTRACT: The majority of parenteral drug products are manufactured in a glass vials with an elastomeric rubber stopper and a crimp cap. The vial sealing process is a critical process step during fill-and-finish operations, as it defines the seal quality of the final product. An adequate force to remove the flip-off button prior to usage is required to ensure product quality during storage and transportation until use. In addition, the complete crimp cap needs to be fixed in a tight position on the vial. In this study, we investigated the torque moment required to turn the crimp cap and the force required to remove the flip-off button of container closure system sealed with different capping equipment process parameters (having different residual seal force values)

    Comparative Investigation of Methods for Analysis of SARS-CoV-2-Spike-Specific Antisera

    No full text
    In light of an increasing number of vaccinated and convalescent individuals, there is a major need for the development of robust methods for the quantification of neutralizing antibodies; although, a defined correlate of protection is still missing. Sera from hospitalized COVID-19 patients suffering or not suffering from acute respiratory distress syndrome (ARDS) were comparatively analyzed by plaque reduction neutralization test (PRNT) and pseudotype-based neutralization assays to quantify their neutralizing capacity. The two neutralization assays showed comparable data. In case of the non-ARDS sera, there was a distinct correlation between the data from the neutralization assays on the one hand, and enzyme-linked immune sorbent assay (ELISA), as well as biophysical analyses, on the other hand. As such, surface plasmon resonance (SPR)-based assays for quantification of binding antibodies or analysis of the stability of the antigen–antibody interaction and inhibition of syncytium formation, determined by cell fusion assays, were performed. In the case of ARDS sera, which are characterized by a significantly higher fraction of RBD-binding IgA antibodies, there is a clear correlation between the neutralization assays and the ELISA data. In contrast to this, a less clear correlation between the biophysical analyses on the one hand and ELISAs and neutralization assays on the other hand was observed, which might be explained by the heterogeneity of the antibodies. To conclude, for less complex immune sera—as in cases of non-ARDS sera—combinations of titer quantification by ELISA with inhibition of syncytium formation, SPR-based analysis of antibody binding, determination of the stability of the antigen–antibody complex, and competition of the RBD-ACE2 binding represent alternatives to the classic PRNT for analysis of the neutralizing potential of SARS-CoV-2-specific sera, without the requirement for a BSL3 facility

    Analysis of BNT162b2- and CVnCoV-elicited sera and of convalescent sera toward SARS-CoV-2 viruses

    No full text
    BACKGROUND: The mRNA vaccine BNT162b2 (Comirnaty, BioNTech/Pfizer) and the vaccine candidate CVnCoV (Curevac) each encode a stabilized spike protein of SARS-CoV2 as antigen but differ with respect to the nature of the mRNA (modified versus unmodified nucleotides) and the mRNA amount (30 μg versus 12 μg RNA). This study characterizes antisera elicited by these two vaccines in comparison to convalescent sera. METHODS: Sera from BNT162b2 vaccinated healthcare workers, and sera from participants of a phase I trial vaccinated with 2, 4, 6, 8, or 12 μg CVnCoV and convalescent sera from hospitalized patients were analyzed by ELISA, neutralization tests, surface plasmon resonance (SPR), and peptide arrays. RESULTS: BNT162b2-elicited sera and convalescent sera have a higher titer of spike-RBD-specific antibodies and neutralizing antibodies as compared to the CVnCoV-elicited sera. For all analyzed sera a reduction in binding and neutralizing antibodies was found for the lineage B.1.351 variant of concern. SPR analyses revealed that the CVnCoV-elicited sera have a lower fraction of slow-dissociating antibodies. Accordingly, the CVnCoV sera almost fail to compete with the spike-ACE2 interaction. The significance of common VOC mutations K417N, E484K, or N501Y focused on linear epitopes was analyzed using a peptide array approach. The peptide arrays showed a strong difference between convalescent sera and vaccine-elicited sera. Specifically, the linear epitope at position N501 was affected by the mutation and elucidates the escape of viral variants to antibodies against this linear epitope. CONCLUSION: These data reveal differences in titer, neutralizing capacity, and affinity of the antibodies between BNT162b2- and CVnCoV-elicited sera, which could contribute to the apparent differences in vaccine efficacy
    corecore