101 research outputs found

    Corporate Social Responsibility/Sustainability Reporting Among the Fortune Global 250: Greenwashing or Green Supply Chain?

    Get PDF
    The sustainability reporting efforts of MNCs who are members of the Fortune Global 250 (FG250) was investigated. The focus was on sustainability reporting by MNCs of supply chain impacts. The reporting of FG250 MNCs was examined to determine if greenwashing was occurring or whether MNCs had committed to operating a green supply chain. A mixed methodology was used consisting of quantitative analysis of twenty-five MNC CSR/sustainability reports which were randomly selected from the FG250 listing. Qualitative analysis using content analysis was also conducted on the reports. Both methodologies concentrated on the sustainability reporting of the selected MNCs in regard to their supply chain. Findings were mixed as there were great variations among the MNCs in their level of sustainability reporting about their supply chains. Some MNCs did not report on the activities of their supply chain at all (20%), the majority of the MNCs reported on their supply chain impacts at the value and goal level (48%), while the rest reported at the management approach level (32%). A majority of the sampled MNCs could be accused of greenwashing due to the lack of detailed quantitative information provided by the MNCs on the environmental impacts of their supply chai

    Angiographically borderline left main coronary artery lesions: correlation of transthoracic doppler echocardiography and intravascular ultrasound: a pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>the clinical decision making could be difficult in patients with borderline lesions (visually assessed stenosis severity of 30 to 50%) of the left main coronary artery (LM). The aim of the study was to evaluate the relationship between transthoracic Doppler (TTDE) peak diastolic flow velocity (PDV) and intravascular ultrasound (IVUS) measurements in the assessment of angiographically borderline LM lesions.</p> <p>Methods</p> <p>27 patients (mean age 64 ± 8 years, 21 males) with borderline LM stenosis referred for IVUS examination were included in the study. We performed standard IVUS with minimal lumen area (MLA) and plaque burden (PB) measurement and routine quantitative coronary angiography (QCA) with diameter stenosis (%DS) and area stenosis (%AS) assessment in all. During TTDE, resting PDV was measured in the LM.</p> <p>Results</p> <p>interpretable Doppler signal could be obtained in 24 patients (88% feasibility); therefore these patients entered the final analysis. MLA was 7.1 ± 2.7 mm<sup>2</sup>. TTDE measured PDV correlated significantly with IVUS-derived MLA (r = -0.46, p < 0.05) and plaque burden (r = 0.51, p < 0.05). Using a velocity cut-off of 112 cm/sec TTDE showed a 92% sensitivity and 62% specificity to identify IVUS-significant (MLA < 6 mm<sup>2</sup>) LM stenosis.</p> <p>Conclusion</p> <p>In angiographically borderline LM disease, resting PDV from transthoracic echocardiography is increased in presence of increased plaque burden by IVUS. TTDE evaluation might be a useful adjunct to other invasive and non-invasive methods in the assessment of borderline LM lesions. Further, large scale studies are needed to establish the exact cut-off value of PDV for routine clinical application.</p

    Potential Prognostic Significance of Decreased Serum Levels of TRAIL after Acute Myocardial Infarction

    Get PDF
    BACKGROUND: Since soluble TRAIL exhibits anti-inflammatory and anti-atherosclerotic activities both in vitro and in animal models, this study was designed to assess the relationship between the serum levels of TRAIL and clinical outcomes in patients with acute myocardial infarction (AMI). METHODOLOGY/PRINCIPAL FINDINGS: Levels of TRAIL were measured by ELISA in serial serum samples obtained from 60 patients admitted for AMI, both during hospitalization and in a follow-up of 12 months, as well as in 60 healthy control subjects. Serum levels of TRAIL were significantly decreased in patients with AMI at baseline (within 24 hours from admission), compared with healthy controls, and showed a significant inverse correlation with a series of negative prognostic markers, such as CK, CK-MB and BNP. TRAIL serum levels progressively increased at discharge, but normalized only at 6-12 months after AMI. Of note, low TRAIL levels at the patient discharge were associated with increased incidence of cardiac death and heart failure in the 12-month follow-up, even after adjustment for demographic and clinical risk parameters (hazard ratio [HR] of 0.93 [95% CI, 0.89 to 0.97]; p = 0.001). CONCLUSIONS/SIGNIFICANCE: Although the number of patients studied was limited, our findings indicate for the first time that circulating TRAIL might represent an important predictor of cardiovascular events, independent of conventional risk markers

    Monocyte Subset Dynamics in Human Atherosclerosis Can Be Profiled with Magnetic Nano-Sensors

    Get PDF
    Monocytes are circulating macrophage and dendritic cell precursors that populate healthy and diseased tissue. In humans, monocytes consist of at least two subsets whose proportions in the blood fluctuate in response to coronary artery disease, sepsis, and viral infection. Animal studies have shown that specific shifts in the monocyte subset repertoire either exacerbate or attenuate disease, suggesting a role for monocyte subsets as biomarkers and therapeutic targets. Assays are therefore needed that can selectively and rapidly enumerate monocytes and their subsets. This study shows that two major human monocyte subsets express similar levels of the receptor for macrophage colony stimulating factor (MCSFR) but differ in their phagocytic capacity. We exploit these properties and custom-engineer magnetic nanoparticles for ex vivo sensing of monocytes and their subsets. We present a two-dimensional enumerative mathematical model that simultaneously reports number and proportion of monocyte subsets in a small volume of human blood. Using a recently described diagnostic magnetic resonance (DMR) chip with 1 µl sample size and high throughput capabilities, we then show that application of the model accurately quantifies subset fluctuations that occur in patients with atherosclerosis

    High-throughput assay for determining enantiomeric excess of chiral diols, amino alcohols, and amines and for direct asymmetric reaction screening

    Get PDF
    Determining enantiomeric excess (e.e.) in chiral compounds is key to development of chiral catalyst auxiliaries and chiral drugs. Here we describe a sensitive and robust fluorescence-based assay for determining e.e. in mixtures of enantiomers of 1,2- and 1,3-diols, chiral amines, amino alcohols, and amino-acid esters. The method is based on dynamic self-assembly of commercially available chiral amines, 2-formylphenylboronic acid, and chiral diols in acetonitrile to form fluorescent diastereomeric complexes. Each analyte enantiomer engenders a diastereomer with distinct fluorescence wavelength/intensity originating from enantiopure fluorescent ligands. In this assay, enantiomers of amines and amine derivatives assemble with diol-type ligands containing a binaphthol moiety (BINOL and VANOL), whereas diol enantiomers form complexes with the enantiopure amine-type fluorescent ligand tryptophanol. The differential fluorescence is utilized to determine the amount of each enantiomer in the mixture with an error of &lt;1% e.e. This method enables high-throughput real-time evaluation of enantiomeric/diastereomeric excess (e.e./d.e.) and product yield of crude asymmetric reaction products. The procedure comprises high-throughput liquid dispensing of three components into 384-well plates and recording of fluorescence using an automated plate reader. The approach enables scaling up the screening of combinatorial libraries and, together with parallel synthesis, creates a robust platform for discovering chiral catalysts or auxiliaries for asymmetric transformations and chiral drug development. The procedure takes ~4–6 h and requires 10–20 ng of substrate per well. Our fluorescence-based assay offers distinct advantages over existing methods because it is not sensitive to the presence of common additives/impurities or unreacted/incompletely utilized reagents or catalysts.</p
    corecore