88 research outputs found

    Bacteria contamination of touch surfaces in Polish hospital wards

    Get PDF
    Background: The objective of the study has been to evaluate the pathogenic bacteria contamination of touch surfaces in hospital wards. Material and Methods: Samples were taken from frequently touched surfaces in the hospital environment in 13 units of various types. Culturing was carried out on solid blood agar and in growth broth (tryptic soy broth – TSB). Species identification was performed using the analytical profile index (API) biochemical testing and confirmed with matrix assisted laser desorption ionization time-flight mass spectrometry (MALDI-TOF-MS) system. Results: The total of 161 samples were taken for the study. Fifty-two of them, after 24 h of culture on a solid medium, demonstrated bacterial growth and further 60 samples had growth after prior multiplication in TSB. Overall, 69.6% of samples exhibited growth of 19 bacterial species. Pathogenic species – representing indicator organisms of efficiency of hospital cleaning – was demonstrated by 21.4% of samples. Among them Acinetobacter spp., Enterocococci spp. and Staphylococcus aureus were identified. Coagulase-negative staphylococci (CNS) were predominant. The proportion of various groups of bacteria significantly varied in respective hospitals, and in various types of wards. Disturbing observation is a large proportion of resistance of isolated CNS strains as a potential reservoir of resistance genes. Conclusions: The results show that touch surfaces in hospital units are contaminated by both potentially pathogenic and pathogenic bacterial species. In connection with the reported, also in Poland, frequent omission or incorrect execution of hand hygiene by hospital staff, and probably patients, touch surfaces still constitute important reservoir of pathogenic bacteria. Improving hand hygiene compliance of health-care workers with recommendations is necessary for increasing biological safety of hospital environment. Med Pr 2017;68(3):459–46

    Antimicrobial effect of copper alloys on Acinetobacter species isolated from infections and hospital environment

    Get PDF
    Abstract Background An increased proportion of Gram-negative bacteria have recently been reported among etiologic agents of infection. In Poland, Acinetobacter baumannii is a big problem for hospitals, especially intensive care units. Touch surfaces made from materials with antimicrobial properties, especially copper alloys, are recommended as a supplementary method of increasing biological safety in the hospital environment. Aim of the study The objective of this study is to determine the susceptibility to selected copper alloys of three clinical Acinetobacter baumannii strains, one Acinetobacter lwoffi and an A. pittii strain isolated from the hospital environment. Material and method The modification of the Japanese Standard, which the ISO 22196:2011 norm was used for testing antimicrobial properties of CuZn37, CuSn6 and CuNi18Zn20 and Cu-ETP and stainless steel as positive and negative control, respectively. Results The highest cidal efficiency, expressed as both time and the degree of reduction of the initial suspension density, against all of the tested Acinetobacter strains was found for ETP copper. But, the results of our study also confirmed effective activity (bacteriocidal or bacteriostatic) of copper alloys selected for the study, contrary to the stainless steel. The reduction in bacterial suspension density is significantly different depending on the strain and copper alloy composition. Conslusions The results of our study confirmed the effective antibacterial activity of copper and its selected alloys against clinical Acinetobacter baumannii and Acinetobacter lwoffii strains, and Acinetobacter pittii strain isolated from the hospital environment

    Antimicrobial resistance in Enterobacterales bacilli isolated from bloodstream infection in surgical patients of Polish hospitals

    Get PDF
    Background and Aims. Bloodstream infections (BSIs) are one of the most frequently observed hospital-acquired infections (HAIs). We sought to describe the epidemiology and drug resistance secondary Enterobacterales BSIs in surgical patients and check for any correlation with the type of hospital ward. Materials and Methods. This multicenter (13 hospitals in southern Poland) laboratory-based retrospective study evaluated adults diagnosed with BSI secondary to surgical site infection (SSI) hospitalized in 2015–2018; 121 Enterobacterales strains were collected. The drug resistance was tested according to the EUCAST recommendations. Tests confirming the presence of extended-spectrum β-lactamases (ESBLs) and bla resistance genes were carried out. The occurrence of possible clonal epidemics among K. pneumoniae strains was examined. Results. The prevalence of Enterobacterales in secondary BSI was 12.1%; the most common strains were E. coli (n = 74, 61.2%) and Klebsiella spp. (n = 33, 27.2%). High resistance involved ampicillin and ampicillin/sulbactam (92, 8–100%), fluoroquinolones (48–73%), and most cephalosporins (29–50%). Carbapenems were the antimicrobials with the susceptibility at 98%. The prevalence of ESBL strains was 37.2% (n = 45). All the ESBL strains had blaCTX-M gene, 26.7% had the blaSHV gene, and 24.4% had blaTEM gene. The diversity of Klebsiella strains was relatively high. Only 4 strains belonged to one clone. Conclusions. What is particularly worrying is the high prevalence of Enterobacterales in BSI, as well as the high resistance to antimicrobial agents often used in the empirical therapy. To improve the effectiveness of empirical treatment in surgical departments, we need to know the epidemiology of both surgical site infection and BSI, secondary to SSI. We were surprised to note high heterogeneity among K. pneumoniae strains, which was different from our previous experience

    Antibiotic resistance, ability to form biofilm and susceptibility to copper alloys of selected staphylococcal strains isolated from touch surfaces in Polish hospital wards

    Get PDF
    Abstract Background Despite the employment of sanitary regimes, contact transmission of the aetiological agents of hospital infections is still exceedingly common. The issue of microbe transmission becomes particularly important when facing multidrug-resistant microorganisms such as methicillin-resistant staphylococci. In the case of deficiencies in cleaning and disinfection procedures, hospital equipment made of copper alloys can play an important role, complementing traditional hospital hygiene procedures. The objective of this study was to characterize staphylococcal strains isolated from touch surfaces in Polish hospital wards in terms of their drug resistance, ability to form biofilm and susceptibility to antimicrobial activity of copper alloys. Methods The materials for the study were 95 staphylococcal strains isolated from touch surfaces in 13 different hospital wards from Małopolska province (the south of Poland). Phenotypic and genotypic antibiotic resistance were checked for erythromycin, clindamycin, gentamycin, ciprofloxacin, trimethoprim/sulfamethoxazole and mupirocin. Biofilm formation ability for the tested strains was checked with the use of culture on Congo red agar. Susceptibility to copper, tin bronze, brass and new silver was tested using a modification of the Japanese standard. Results Over 67% of the analysed staphylococcal strains were methicillin-resistant (MR). Four strains were resistant to all of the tested antibiotics, and 14 were resistant to all except mupirocin. Strains classified as MR had significantly increased resistance to the remaining antibiotic groups. About one-third of the analysed strains revealed biofilm-forming ability. Among the majority of species, biofilm-forming and non-biofilm-forming strains were distributed evenly; in the case of S. haemolyticus only, negative strains accounted for 92.8%. Susceptibility to copper alloys was different between strains and rather lower than in the case of the SA strain selected for comparison. Conclusions Coagulase-negative staphylococci, the most commonly isolated in Polish hospital wards, should not be neglected as an infection risk factor due their high antibiotic resistance. Our experiments confirmed that touch surfaces made of copper alloys may play an important role in eliminating bacteria from the hospital environment

    Dynamic versus Adynamic Graciloplasty in Treatment of End-Stage Fecal Incontinence: Is the Implantation of the Pacemaker Really Necessary? 12-Month Follow-Up in a Clinical, Physiological, and Functional Study

    Get PDF
    Purpose. The aim of the study is to compare functional results of end-stage fecal incontinence treatment with dynamic graciloplasty and adynamic graciloplasty augmented with transanal conditioning of the transposed muscle. Methods. A total of 20 patients were qualified for graciloplasty procedure due to end-stage fecal incontinence. 7 patients underwent dynamic graciloplasty (DGP), whereas 13 patients were treated with adynamic graciloplasty, with transanal stimulation in the postoperative period (AGP). Clinical, functional, and quality of life assessments were performed 3, 6, and 12 months after the procedures. Results. There were no intraoperative or early postoperative complications. The detachment of gracilis muscle tendon was observed in one patient in DGP group and two in AGP group. There was a significant improvement of Fecal Incontinence Quality of Life (FIQL) and Fecal Incontinence Severity Index (FISI) scores in both groups 12 months after procedure. Anorectal manometry showed improvement regarding basal and squeeze pressures in both groups, with significantly better squeeze pressures in AGP group. Conclusions. The functional effects in the DGP and AGP groups were similar. Significantly lower price of the procedure and avoidance of implant-related complication risk suggest the attractiveness of the AGP method augmented by transanal stimulation

    The general status of patients and limited physical activity as risk factors of Methicillin-resistant Staphylococcus aureus occurrence in long-term care facilities residents in Krakow, Poland

    Get PDF
    BACKGROUND: The aim of this study was to investigate the epidemiology and resistance of methicillin-resistant Staphylococcus aureus (MRSA) isolates from long-term care facilities (LTCF) residents and to analyze the potential risk factors for MRSA occurrence, defined as MRSA colonization and/or infection. METHODS: Point prevalence (PPS) and prospective incidence continuous study (CS) was carried out on a group of 193 residents in 2009-2010. RESULTS: Overall MRSA occurred (with or without infection) among 17.6% of residents. There was 16 cases of infections with SA aetiology, of which 10 (58.8%) were caused by MRSA. The MRSA prevalence in PPS was 12.9%, in CS infection incidence rate was 5.2%. Factors associated with MRSA occurrence were: general status of patients, limited physical activity, wound infections (odds ratio, OR 4.6), ulcers in PPS (OR 2.1), diabetes (OR 1.6), urinary catheterization (OR 1.6) and stool incontinence (OR 1.2). CONCLUSIONS: Our data indicate a need for screening of MRSA before hospitalization or transfer to rehabilitation centres, especially in a group of residents with limitations in physical activity – i.e. with the highest risk of MRSA. Results also suggest the need for contact precautions in patients with high risk of MRSA occurrence, only. Focus on the high-risk population might be a solution for the cost-effective surveillance
    corecore