14 research outputs found

    Whole blood impedance aggregometry findings in experimental endotoxinemia

    Full text link

    A prospective randomized open-label trial on the comparative effects of 6% hydroxyethyl starch 130/0.4 versus polyionic isotonic crystalloids on coagulation parameters in dogs with spontaneous hemoperitoneum

    No full text
    Objective: To evaluate the effects of 6% hydroxyethyl starch 130/0.4 (HES) and a polyionic isotonic crystalloid (CRYS) on standard coagulation tests and rotational thromboelastometry (ROTEM) in dogs with spontaneous hemoperitoneum (SHP). Design: Prospective randomized open-label clinical study. Setting: University teaching hospital. Animals: Forty-two client-owned dogs presented with SHP. Interventions: Dogs diagnosed with SHP and hypovolemic shock were randomly allocated to receive HES (10 mL/kg, n = 22) or CRYS (30 mL/kg, n = 20) intravenously over 20 minutes for hemodynamic stabilization. Measurements and main results: Parameters measured before (T0 ) and after (T1 ) treatment were HCT, platelet counts, prothrombin time, activated partial thromboplastin time, fibrinogen concentrations, and extrinsic activated (EXTEM), intrinsic activated (INTEM), and extrinsic activated with platelet inhibition ROTEM assays. Data were analyzed as absolute values and as the percentage change from T0 to T1 . No significant differences between groups were detected in any variable at T0 , and for HCT, platelet counts, prothrombin time, activated thromboplastin time, and fibrinogen concentrations at T1 . Clot formation time in EXTEM was significantly prolonged (P = 0.037), and maximum clot firmness was significantly decreased (P = 0.038) in the HES group compared to the CRYS group at T1 . The percentage change in EXTEM clotting time (P = 0.012) and INTEM clot formation time (P = 0.031) was greater after HES than CRYS. Lysis indices remained at 100% for all ROTEM assays in both groups. Conclusion: Compared to a 3-fold volume of CRYS, administration of HES was associated with impairment in ROTEM parameters in dogs with SHP, but no evidence of hyperfibrinolysis was detected

    Glycocalyx components affect platelet function, whole blood coagulation, and fibrinolysis: an in vitro study suggesting a link to trauma-induced coagulopathy

    No full text
    Background!#!The mechanisms of trauma induced coagulopathy (TIC) are considered multifactorial. Amongst others, however, shedding of the endothelial glycocalyx resulting in increased concentrations of glycocalyx fragments in plasma might also play a role. Thus, we hypothesized that shedded glycocalyx components affect coagulation and may act as humoral mediators of TIC.!##!Methods!#!To investigate effects of heparan sulfate, chondroitin sulfate, syndecan-1, versican, and thrombomodulin we added these fragments to in vitro assays of whole blood from healthy volunteers to yield concentrations observed in trauma patients. Platelet function, whole blood coagulation, and fibrinolysis were measured by standard coagulation tests, impedance aggregometry (IA), and viscoelastic tests (VET). To assess dose-response relationships, we performed IA with increasing concentrations of versican and VET with increasing concentrations of thrombomodulin.!##!Results!#!Intrinsically activated clotting times (i.e., activated partial thromboplastin time and intrinsically activated VET with and without heparinase) were unaffected by any glycocalyx fragment. Thrombomodulin, however, significantly and dose-dependently diminished fibrinolysis as assessed by VET with exogenously added rt-PA, and increased rt-PA-induced lysis Indices after 30 (up to 108% of control, p <  0,0001), 45 (up to 368% of control, p <  0,0001), and 60 min (up to 950% of control, p <  0,0001) in VET. Versican impaired platelet aggregation in response to arachidonic acid (up to - 37,6%, p <  0,0001), ADP (up to - 14,5%, p <  0,0001), and collagen (up to - 31,8%, p <  0,0001) in a dose-dependent manner, but did not affect TRAP-6 induced platelet aggregation. Clotting time in extrinsically activated VET was shortened by heparan sulfate (- 7,2%, p = 0,024), chondroitin sulfate (- 11,6%, p = 0,016), versican (- 13%, p = 0,012%), and when combined (- 7,2%, p = 0,007).!##!Conclusions!#!Glycocalyx components exert distinct inhibitory effects on platelet function, coagulation, and fibrinolysis. These data do not support a 'heparin-like auto-anticoagulation' by shed glycosaminoglycans but suggest a possible role of versican in trauma-induced thrombocytopathy and of thrombomodulin in trauma-associated impairment of endogenous fibrinolysis

    The role of evidence-based algorithms for rotational thromboelastometry-guided bleeding management

    No full text
    Rotational thromboelastometry (ROTEM) is a point-of-care viscoelastic method and enables to assess viscoelastic profiles of whole blood in various clinical settings. ROTEM-guided bleeding management has become an essential part of patient blood management (PBM) which is an important concept in improving patient safety. Here, ROTEM testing and hemostatic interventions should be linked by evidence-based, setting-specific algorithms adapted to the specific patient population of the hospitals and the local availability of hemostatic interventions. Accordingly, ROTEM-guided algorithms implement the concept of personalized or precision medicine in perioperative bleeding management ('theranostic' approach). ROTEM-guided PBM has been shown to be effective in reducing bleeding, transfusion requirements, complication rates, and health care costs. Accordingly, several randomized-controlled trials, meta-analyses, and health technology assessments provided evidence that using ROTEM-guided algorithms in bleeding patients resulted in improved patient's safety and outcomes including perioperative morbidity and mortality. However, the implementation of ROTEM in the PBM concept requires adequate technical and interpretation training, education and logistics, as well as interdisciplinary communication and collaboration

    Impact of Bioprosthetic Choice on Mortality After Transfemoral Transcatheter Aortic Valve Implantation in Patients With Reduced Versus Preserved Left-Ventricular Ejection Fraction

    No full text
    The outcome of transfemoral transcatheter aortic valve implantation (TF-TAVI) with a selfexpanding (SEP) versus a balloon-expandable prosthesis (BEP) in patients with a reduced ejection fraction (rEF, = II degrees (21% vs 10%, p = 0.07), but both factors could not explain the excess mortality after SEP-implantation in the multivariate analysis. In patients with rEF, the use of a SEP was an independent predictor of 1-year mortality (HR 2.44, 95% CI 1.27 to 4.27, p = 0.007). In conclusion, patients with rEF had a higher 1-year mortality after TF-TAVI when a SEP instead of a BEP was used. (C) 2020 Elsevier Inc. All rights reserved
    corecore