7 research outputs found

    Towards contactless optical coherence elastography with acoustic tissue excitation

    No full text
    Elastography presents an interesting approach to complement image data with mechanical tissue properties. Typically, the tissue is excited by direct contact to a probe. We study contactless elastography based on optical coherence tomography (OCT) and dynamic acoustic tissue excitation with airborne sound. We illustrate the principle and an implementation using sound waves of 135 Hz to excite the tissue. The displacement is measured and results of several tests indicate the feasibility to obtain a qualitative measure of the mechanical tissue properties. The approach is interesting for optical palpation, e.g., to enhance navigation and tissue characterization in minimally invasive and robot-assisted surgery

    Towards contactless optical coherence elastography with acoustic tissue excitation

    No full text
    Elastography presents an interesting approach to complement image data with mechanical tissue properties. Typically, the tissue is excited by direct contact to a probe. We study contactless elastography based on optical coherence tomography (OCT) and dynamic acoustic tissue excitation with airborne sound. We illustrate the principle and an implementation using sound waves of 135 Hz to excite the tissue. The displacement is measured and results of several tests indicate the feasibility to obtain a qualitative measure of the mechanical tissue properties. The approach is interesting for optical palpation, e.g., to enhance navigation and tissue characterization in minimally invasive and robot-assisted surgery.Deutsche Forschungsgemeinschaft (DFG

    Two-stage revision hip arthroplasty with a cementless stem in cases of periprosthetic joint infection

    Full text link
    Background: Two-stage revision arthroplasty is today regarded as the gold standard treatment method for deep prosthetic joint infection. The aim of the present study was to evaluate clinical and functional outcomes with the Modular Universal Tumor And Revision System (MUTARS) RS stem in patients undergoing two-stage revisions. Methods: The functional and clinical outcomes for 43 patients who had undergone two-stage revision procedures for PJI were analyzed in a retrospective study. The minimum follow-up period was 24 months. Shorter follow-up periods were only observed when there were complications such as loosening or recurrent infection. The mean follow-up period was 3.86 years (range 7 months to 11.6 years). Results: The success rate with infection control for PJI was 93%. Reinfection occurred in four cases (7%). The risk of reinfection after MRSA infection was 20.5 times greater (P >0.01) than with sensitive or unknown bacteria. Two aseptic loosening occurred after 7 and 20 months. The average Harris Hip Score was 80 (range 62–93). Conclusion: This retrospective study showed a 93% rate of eradication using specific antibiotic therapy. With the modular MUTARS RS stem, there was a low rate of aseptic loosening of 4.6%. MRSA infection was identified as a risk factor for reinfection. The two-stage procedure with modular cementless implants used is therefore appropriate for treating periprosthetic infections associated with hip endoprostheses.<br
    corecore