124 research outputs found
Politics and Community-Based Research
Politics and Community-Based Research: Perspectives from Yeoville Studio, Johannesburg offers a substantive and compelling analysis for a diverse readership interested in urban politics, community mapping and the built environment. The book draws on a critical reflection of Yeoville Studio, a research project conducted by Wits University academics from a diversity of disciplinary backgrounds, together with community partners and postgraduate students. A collection of vignettes portraying people and places in Yeoville interwoven with theoretically analytical chapters, it explores the politics of community research at a neighbourhood scale in its multiple facets, and will resonate with similar contested and complex neighbourhoods across the world. The mix of analysis, vignettes, photographs, architectural design and graphics builds the discussion in engaging, rich and integrated ways, to capture the many participatory approaches taken to this city-community studio
Remote monitoring of patients with implantable cardioverter-defibrillators: Can results from large clinical trials be transposed to clinical practice?
SummaryBackgroundRemote monitoring (RM) is increasingly used to follow up patients with implantable cardioverter-defibrillators (ICDs). Randomized control trials provide evidence for the benefit of this intervention, but data for RM in daily clinical practice with multiple-brands and unselected patients is lacking.AimsTo assess the effect of RM on patient management and clinical outcome for recipients of ICDs in daily practice.MethodsWe reviewed ICD recipients followed up at our institution in 2009 with RM or with traditional hospital only (HO) follow-up. We looked at the effect of RM on the number of scheduled ambulatory follow-ups and urgent unscheduled consultations, the time between onset of asymptomatic events to clinical intervention and the clinical effectiveness of all consultations. We also evaluated the proportion of RM notifications representing clinically relevant situations.ResultsWe included 355 patients retrospectively (RM: n=144, HO: n=211, 76.9% male, 60.3±15.2years old, 50.1% with ICDs for primary prevention and mean left ventricular ejection fraction 35.5±14.5%). Average follow-up was 13.5months. The RM group required less scheduled ambulatory follow-up consultations (1.8 vs. 2.1/patient/year; P<0.0001) and a far lower median time between the onset of asymptomatic events and clinical intervention (7 vs. 76days; P=0.016). Of the 784 scheduled ambulatory follow-up consultations carried out, only 152 (19.4%) resulted in therapeutic intervention or ICD reprogramming. We also found that the vast majority of RM notifications (61.9%) were of no clinical relevance.ConclusionRM allows early management of asymptomatic events and a reduction in scheduled ambulatory follow-up consultations in daily clinical practice, without compromising safety, endorsing RM as the new standard of care for ICD recipients
Baroreflex Activation Therapy for the Treatment of Heart Failure With a Reduced Ejection Fraction
AbstractObjectivesThe objective of this clinical trial was to assess the safety and efficacy of carotid BAT in advanced HF.BackgroundIncreased sympathetic and decreased parasympathetic activity contribute to heart failure (HF) symptoms and disease progression. Baroreflex activation therapy (BAT) results in centrally mediated reduction of sympathetic outflow and increased parasympathetic activity.MethodsPatients with New York Heart Association (NYHA) functional class III HF and ejection fractions ≤35% on chronic stable guideline-directed medical therapy (GDMT) were enrolled at 45 centers in the United States, Canada, and Europe. They were randomly assigned to receive ongoing GDMT alone (control group) or ongoing GDMT plus BAT (treatment group) for 6 months. The primary safety end point was system- and procedure-related major adverse neurological and cardiovascular events. The primary efficacy end points were changes in NYHA functional class, quality-of-life score, and 6-minute hall walk distance.ResultsOne hundred forty-six patients were randomized, 70 to control and 76 to treatment. The major adverse neurological and cardiovascular event–free rate was 97.2% (lower 95% confidence bound 91.4%). Patients assigned to BAT, compared with control group patients, experienced improvements in the distance walked in 6 min (59.6 ± 14 m vs. 1.5 ± 13.2 m; p = 0.004), quality-of-life score (–17.4 ± 2.8 points vs. 2.1 ± 3.1 points; p < 0.001), and NYHA functional class ranking (p = 0.002 for change in distribution). BAT significantly reduced N-terminal pro–brain natriuretic peptide (p = 0.02) and was associated with a trend toward fewer days hospitalized for HF (p = 0.08).ConclusionsBAT is safe and improves functional status, quality of life, exercise capacity, N-terminal pro–brain natriuretic peptide, and possibly the burden of heart failure hospitalizations in patients with GDMT-treated NYHA functional class III HF. (Barostim Neo System in the Treatment of Heart Failure; NCT01471860; Barostim HOPE4HF [Hope for Heart Failure] Study; NCT01720160
Radio-frequency ablation as primary management of well-tolerated sustained monomorphic ventricular tachycardia in patients with structural heart disease and left ventricular ejection fraction over 30%
Aims Patients with well-tolerated sustained monomorphic ventricular tachycardia (SMVT) and left ventricular ejection fraction (LVEF) over 30% may benefit from a primary strategy of VT ablation without immediate need for a ‘back-up' implantable cardioverter-defibrillator (ICD). Methods and results One hundred and sixty-six patients with structural heart disease (SHD), LVEF over 30%, and well-tolerated SMVT (no syncope) underwent primary radiofrequency ablation without ICD implantation at eight European centres. There were 139 men (84%) with mean age 62 ± 15 years and mean LVEF of 50 ± 10%. Fifty-five percent had ischaemic heart disease, 19% non-ischaemic cardiomyopathy, and 12% arrhythmogenic right ventricular cardiomyopathy. Three hundred seventy-eight similar patients were implanted with an ICD during the same period and serve as a control group. All-cause mortality was 12% (20 patients) over a mean follow-up of 32 ± 27 months. Eight patients (40%) died from non-cardiovascular causes, 8 (40%) died from non-arrhythmic cardiovascular causes, and 4 (20%) died suddenly (SD) (2.4% of the population). All-cause mortality in the control group was 12%. Twenty-seven patients (16%) had a non-fatal recurrence at a median time of 5 months, while 20 patients (12%) required an ICD, of whom 4 died (20%). Conclusion Patients with well-tolerated SMVT, SHD, and LVEF > 30% undergoing primary VT ablation without a back-up ICD had a very low rate of arrhythmic death and recurrences were generally non-fatal. These data would support a randomized clinical trial comparing this approach with others incorporating implantation of an ICD as a primary strateg
Impact of early complications on outcomes in patients with implantable cardioverter-defibrillator for primary prevention
International audienceBackground - The lifesaving benefit of implantable cardioverter-defibrillators (ICDs) has been demonstrated. Their use has increased considerably in the past decade, but related complications have become a major concern. Objective - The purpose of this study was to assess the incidence and effect on outcomes of early (≤30 days) complications after ICD implantation for primary prevention in a large French population. Methods - We analyzed data from 5539 patients from the multicenter French DAI-PP (Défibrillateur Automatique Implantable-Prévention Primaire) registry (2002-2012) who had coronary artery disease or dilated cardiomyopathy and were implanted with an ICD for primary prevention. Results - Overall, early complications occurred in 707 patients (13.5%), mainly related to lead dislodgment or hematoma (57%). Independent factors associated with occurrence of early complications were severe renal impairment (odds ratio [OR] 1.66, 95% confidence interval [CI] 1.17-2.37, P = .02), age ≥75 years (OR 1.01, 95% CI 1.00-1.02, P = .03), cardiac resynchronization therapy (OR 1.58, 95% CI 1.16-2.17, P = .01), and anticoagulant therapy (OR 1.28, 95% CI 1.02-1.61, P = .03). During a mean ± SD follow-up of 3.1 ± 2.3 years, 824 (15.8%) patients experienced ≥1 late complication (>30 days), and 782 (14.9%) patients died. After adjustment, early complications remained associated with occurrence of late complications (OR 2.15, 95% CI 1.73-2.66, P < .0001) and mortality (OR 1.70, 95% CI 1.34-2.17, P = .003). Conclusion - Early complications are common after ICD implantation for primary prevention, occurring in 1 in 7 patients, and are associated with an increased risk of late complications and overall mortality. Further studies are needed to investigate the underlying mechanisms of such associations
Lesion-induced DNA weak structural changes detected by pulsed EPR spectroscopy combined with site-directed spin labelling
Double electron-electron resonance (DEER) was applied to determine nanometre spin–spin distances on DNA duplexes that contain selected structural alterations. The present approach to evaluate the structural features of DNA damages is thus related to the interspin distance changes, as well as to the flexibility of the overall structure deduced from the distance distribution. A set of site-directed nitroxide-labelled double-stranded DNA fragments containing defined lesions, namely an 8-oxoguanine, an abasic site or abasic site analogues, a nick, a gap and a bulge structure were prepared and then analysed by the DEER spectroscopic technique. New insights into the application of 4-pulse DEER sequence are also provided, in particular with respect to the spin probes’ positions and the rigidity of selected systems. The lesion-induced conformational changes observed, which were supported by molecular dynamics studies, confirm the results obtained by other, more conventional, spectroscopic techniques. Thus, the experimental approaches described herein provide an efficient method for probing lesion-induced structural changes of nucleic acids
Les infections sur les sondes endocavitaires de stimulation cardiaque permanente (de la physiopathologie à la clinique)
LILLE2-BU Santé-Recherche (593502101) / SudocPARIS-BIUP (751062107) / SudocSudocFranceF
Facteurs prédictifs de mort subite (importance des polymorphismes des récepteurs béta-adrénergiques)
LILLE2-BU Santé-Recherche (593502101) / SudocPARIS-BIUM (751062103) / SudocSudocFranceF
Défibrillateur implantable et infection (étude monocentrique lilloise)
LILLE2-BU Santé-Recherche (593502101) / SudocPARIS-BIUM (751062103) / SudocSudocFranceF
- …