59 research outputs found

    Coronary Obstruction Following Transcatheter Aortic Valve Implantation for Degenerative Bioprosthetic Surgical Valves: a Systematic Literature Review

    Get PDF
    ABSTRACTBackgroundVery few data exist on coronary obstruction following transcatheter aortic valve implantation (TAVI) for degenerative bioprosthetic valves (valve-in-valve [ViV]). The present trial evaluated, through a systematic review of the literature, the clinical characteristics, management and clinical outcomes of patients with coronary obstruction after ViV-TAVI.MethodsStudies published between 2002 and 2013 evaluating coronary obstruction as a complication of ViV-TAVI were identified using a systematic electronic search. Data on the clinical and procedural characteristics, management of the complication, and clinical outcomes were analyzed.ResultsA total of four publications describing seven patients were identified. Most patients (71%) were women, with mean age of 82±5 years, and STS-PROM score of 9.4±2.6%. Mean left coronary artery (LCA) ostium height and aortic root width were 8.8±1.5mm and 28.0±5.0mm, respectively. Most patients had stented bioprosthetic valves with externally mounted leaflets or stentless aortic bioprosthesis, and the LCA was involved in all patients. Percutaneous coronary intervention (PCI) was attempted in all patients and was successful in four (57%). In-hospital mortality was 42.9% (three cases), all of them after failed PCI.ConclusionsCoronary obstruction following ViV-TAVI occurred more frequently in women with stented bioprosthetic valves with externally mounted leaflets or with stentless bioprosthesis. The LCA was involved in all cases and PCI was successful in 60% of them. Continued efforts may help identify the factors associated with this complication so that appropriate prevention measures may be implemented

    Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis

    Get PDF
    ObjectivesThis study was undertaken to compare the hemodynamic performance of a percutaneous bioprosthesis to that of surgically implanted (stented and stentless) bioprostheses for the treatment of severe aortic stenosis.MethodsFifty patients who underwent percutaneous aortic valve implantation (PAVI) with the Cribier-Edwards or Edwards SAPIEN bioprosthetic valve (Edwards Lifesciences, Inc., Irvine, California) were matched 1:1 for sex, aortic annulus diameter, left ventricular ejection fraction, body surface area, and body mass index, with 2 groups of 50 patients who underwent surgical aortic valve replacement (SAVR) with a stented valve (Edwards Perimount Magna [SAVR-ST group]), or a stentless valve (Medtronic Freestyle, Medtronic, Minneapolis, Minnesota [SAVR-SL group]). Doppler echocardiographic data were prospectively obtained before the intervention, at discharge, and at 6- to 12-month follow-up.ResultsMean transprosthetic gradient at discharge was lower (p < 0.001) in the PAVI group (10 ± 4 mm Hg) compared with the SAVR-ST (13 ± 5 mm Hg) and SAVR-SL (14 ± 6 mm Hg) groups. Aortic regurgitation (AR) occurred more frequently in the PAVI group (mild: 42%, moderate: 8%) compared with the SAVR-ST (mild: 10%, moderate: 0%) and SAVR-SL (mild: 12%, moderate: 0%) groups (p < 0.0001). At follow-up, the mean gradient in the PAVI group remained lower (p < 0.001) than that of the SAVR-ST group, but was similar to that of the SAVR-SL group. The incidence of severe prosthesis-patient mismatch was significantly lower (p = 0.007) in the PAVI group (6%) compared with the SAVR-ST (28%) and SAVR-SL (20%) groups. However, the incidence of AR remained higher (p < 0.0001) in the PAVI group compared with the 2 other groups.ConclusionsPAVI provided superior hemodynamic performance compared with the surgical bioprostheses in terms of transprosthetic gradient and prevention of severe prosthesis-patient mismatch, but was associated with a higher incidence of AR

    Impact of Low Flow on the Outcome of High-Risk Patients Undergoing Transcatheter Aortic Valve Replacement

    Get PDF
    ObjectivesThis study sought to assess the impact of baseline left ventricular (LV) outflow, LV ejection fraction (LVEF), and transvalvular gradient on outcomes following transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis (AS).BackgroundLow flow (i.e., reduced stroke volume index [SVi]) can occur with both reduced and preserved LVEF. Low flow is often associated with low gradient despite severe stenosis and with worse outcomes following surgical aortic valve replacement. However, there are few data about the impact of low flow on outcomes following TAVR.MethodsWe retrospectively analyzed the clinical, Doppler-echocardiographic, and outcome data prospectively collected in 639 patients who underwent TAVR for symptomatic severe AS in 2 Canadian centers.ResultsIn this cohort, 334 (52.3%) patients had a low flow (SVi <35 ml/m2) and these patients had increased 30-day mortality (11.4 vs. 5.9%, p = 0.01), 2-year all-cause mortality (35.3 vs. 30.9%, p = 0.005), and 2-year cardiovascular mortality (25.7 vs. 16.8%, p = 0.01) compared with patients with normal flow. Reduced flow was an independent predictor of 30-day mortality (odds ratio: 1.94, p = 0.026), cumulative all-cause mortality (hazard ratio: 1.27 per 10 ml/m² SVi decrease, p = 0.016), and cumulative cardiovascular mortality (hazard ratio: 1.29 per 10 ml/m² decrease, p = 0.04). Despite significant association in univariable analyses, low LVEF and low mean gradient were not found to be independent predictors of outcomes in multivariable analyses.ConclusionsLow flow but not low LVEF or low gradient is an independent predictor of early and late mortality following TAVR in high-risk patients with severe AS. SVi should be integrated in the risk stratification process of these patients

    Risk Score, Causes, and Clinical Impact of Failure of Transradial Approach for Percutaneous Coronary Interventions

    Get PDF
    ObjectivesTo study the causes of and to develop a risk score for failure of transradial approach (TRA) for percutaneous coronary intervention (PCI).BackgroundTRA-PCI failure has been reported in 5% to 10% of cases.MethodsTRA-PCI failure was categorized as primary (clinical reasons) or crossover failure. Multivariate analysis was performed to determine independent predictors of TRA-PCI failure, and an integer risk score was developed.ResultsFrom January to June 2010, TRA-PCI was attempted in 1,609 (97.3%) consecutive patients, whereas 45 (2.7%) had primary TRA-PCI failure. Crossover TRA-PCI failure occurred in 30 (1.8%) patients. Causes of primary TRA-PCI failure included chronic radial artery occlusion (11%), previous coronary artery bypass graft (27%), and cardiogenic shock (20%). Causes for crossover TRA-PCI failure included: inadequate puncture in 17 patients (57%); radial artery spasm in 5 (17%); radial loop in 4 (13%); subclavian tortuosity in 2 (7%); and inadequate guide catheter support in 2 (7%) patients. Female sex (odds ratio [OR]: 3.2; 95% confidence interval [CI]: 1.95 to 5.26, p < 0.0001), previous coronary artery bypass graft (OR: 6.1; 95% CI: 3.63 to 10.05, p < 0.0001), and cardiogenic shock (OR: 11.2; 95% CI: 2.78 to 41.2, p = 0.0011) were independent predictors of TRA-PCI failure. Risk score values from 0 to 7 predicted a TRA-PCI failure rate from 2% to 80%.ConclusionsIn a high-volume radial center, 2.7% of patients undergoing PCI are excluded from initial TRA on clinical grounds, whereas crossover to femoral approach is required in only 1.8% of the cases. A new simple clinical risk score is developed to predict TRA-PCI failure

    Myocardial injury following transcatheter aortic valve implantation : insights from delayed-enhancement cardiovascular magnetic resonance

    Get PDF
    Aims: The aim of this study was to evaluate the presence, localisation and extent of myocardial injury as determined by late gadolinium enhancement (LGE) on cardiovascular magnetic resonance (CMR) imaging in patients undergoing transcatheter aortic valve implantation (TAVI). Methods and results: A total of 37 patients, who underwent successful TAVI with a balloon-expandable valve (transapical [TA], n=11; non-TA, n=26), were included. Cardiac biomarker (CK-MB and cTnT) lev- els were determined at baseline and following TAVI. CMR was performed within a week before and within 30 days following TAVI. Some increase in cardiac biomarkers was detected in 97% of the patients as deter- mined by a rise in cTnT, and in 49% of the patients as determined by a rise in CK-MB. Following TAVI, no new myocardial necrosis defects were observed with the non-TA approach. Nonetheless, all patients who underwent TAVI through the TA approach had new focal myocardial necrosis in the apex, with a median myo-cardial extent and necrotic mass of 5% [2.0-7.0] and 3.5 g [2.3-4.5], respectively. Conclusions: Although some increase in cardiac biomarkers of myocardial injury was systematically detected following TAVI, new myocardial necrosis as evaluated by CMR was observed only in patients undergoing the procedure through the TA approach, involving ~5% of the myocardium in the apex

    Obesity Indexes and Total Mortality among Elderly Subjects at High Cardiovascular Risk: The PREDIMED Study

    Get PDF
    BackgroundDifferent indexes of regional adiposity have been proposed for identifying persons at higher risk of death. Studies specifically assessing these indexes in large cohorts are scarce. It would also be interesting to know whether a dietary intervention may counterbalance the adverse effects of adiposity on mortality.MethodsWe assessed the association of four different anthropometric indexes (waist-to-height ratio (WHtR), waist circumference (WC), body mass index (BMI) and height) with all-cause mortality in 7447 participants at high cardiovascular risk from the PREDIMED trial. Forty three percent of them were men (55 to 80 years) and 57% were women (60 to 80 years). All of them were initially free of cardiovascular disease. The recruitment took place in 11 recruiting centers between 2003 and 2009.ResultsAfter adjusting for age, sex, smoking, diabetes, hypertension, intervention group, family history of coronary heart disease, and leisure-time physical activity, WC and WHtR were found to be directly associated with a higher mortality after 4.8 years median follow-up. The multivariable-adjusted HRs for mortality of WHtR (cut-off points: 0.60, 0.65, 0.70) were 1.02 (0.78–1.34), 1.30 (0.97–1.75) and 1.55 (1.06–2.26). When we used WC (cut-off points: 100, 105 and 110 cm), the multivariable adjusted Hazard Ratios (HRs) for mortality were 1.18 (0.88–1.59), 1.02 (0.74–1.41) and 1.57 (1.19–2.08). In all analyses, BMI exhibited weaker associations with mortality than WC or WHtR. The direct association between WHtR and overall mortality was consistent within each of the three intervention arms of the trial.ConclusionsOur study adds further support to a stronger association of abdominal obesity than BMI with total mortality among elderly subjects at high risk of cardiovascular disease. We did not find evidence to support that the PREDIMED intervention was able to counterbalance the harmful effects of increased adiposity on total mortality.Trial RegistrationControlled-Trials.com ISRCTN3573963

    Topographie du tissu adipeux et profil de risque cardiométabolique des jeunes adultes apparemment en santé

    Get PDF
    Tableau d’honneur de la Faculté des études supérieures et postdoctorales, 2012-2013.Les jeunes adultes apparemment en santé, chez qui la prévalence d’athérosclérose asymptomatique est étonnamment élevée, devraient pouvoir bénéficier de stratégies préventives efficaces en matière de santé cardiométabolique. Notre étude a examiné la pertinence et la façon d’évaluer l’adiposité régionale chez les jeunes adultes apparemment en santé en mesurant les associations qui existent entre les différents tissus adipeux (sous-cutané abdominal, viscéral abdominal et épicardique) et les marqueurs du profil de risque cardiométabolique, ainsi que les associations qui existent entre les différents tissus adipeux et les mesures anthropométriques (indice de masse corporelle, tour de taille et ratio taille/hanche). Nos résultats suggèrent la pertinence d’évaluer spécifiquement les quantités de tissu adipeux viscéral abdominal et épicardique chez les jeunes adultes apparemment en santé. Notre étude a également déterminé qu’en plus de simplement calculer l’indice de masse corporelle, mesurer le tour de taille chez les jeunes adultes apparemment en santé permet de mieux discriminer les individus avec une accumulation de tissu adipeux viscéral et épicardique augmentée

    Transcatheter aortic valve implantation in patients with severe aortic stenosis and small aortic annulus

    Get PDF
    Objectives: Valve hemodynamics and clinical outcomes among patients with a small aortic annulus who underwent transcatheter aortic valve implantation (TAVI) were examined. Background: The presence of a small aortic annulus may complicate the surgical management of patients with severe aortic stenosis (AS). TAVI is an alternative to aortic valve replacement (AVR) in high-risk patients, but few data exist on the results of TAVI in patients with a small aortic annulus. Methods: Between 2007 and 2010, 35 patients (mean age 79.2 ± 9.4 years) with severe AS and an aortic annulus diameter <20 mm (mean 18.5 ± 0.9 mm) underwent TAVI with a 23-mm Edwards SAPIEN bioprosthesis (Edwards Lifesciences, Inc., Irvine, California). Echocardiographic parameters and clinical outcomes were assessed prior to discharge and at 6, 12, and 24 months. Results: Procedural success was achieved in 34 patients (97.1%). There was 1 in-hospital death. Peak and mean transaortic gradients decreased from 76.3 ± 33.0 mm Hg and 45.2 ± 20.6 mm Hg at baseline to 21.8 ± 8.4 mm Hg and 11.7 ± 4.8 mm Hg post-procedure, respectively, both p < 0.0001. Mean indexed effective orifice area (IEOA) increased from 0.35 ± 0.10 cm2/m2 at baseline to 0.90 ± 0.18 cm2/m2 post-procedure, p < 0.0001. Severe prosthesis–patient mismatch (IEOA <0.65 cm2/m2) occurred in 2 patients (5.9%). At a mean follow-up of 14 ± 11 months, gradients remained low and 30 of the 31 remaining survivors were in New York Heart Association functional class I or II. Conclusions: In high-risk patients with severe AS and a small aortic annulus, TAVI is associated with good post-procedural valve hemodynamics and clinical outcomes. TAVI may provide a reasonable alternative to conventional AVR in elderly patients with a small aortic annulus
    • …
    corecore