15 research outputs found

    Stress echo 2020 : the international stress echo study in ischemic and non-ischemic heart disease

    Get PDF
    Background: Stress echocardiography (SE) has an established role in evidence-based guidelines, but recently its breadth and variety of applications have extended well beyond coronary artery disease (CAD). We lack a prospective research study of SE applications, in and beyond CAD, also considering a variety of signs in addition to regional wall motion abnormalities. Methods: In a prospective, multicenter, international, observational study design, > 100 certified high-volume SE labs (initially from Italy, Brazil, Hungary, and Serbia) will be networked with an organized system of clinical, laboratory and imaging data collection at the time of physical or pharmacological SE, with structured follow-up information. The study is endorsed by the Italian Society of Cardiovascular Echography and organized in 10 subprojects focusing on: contractile reserve for prediction of cardiac resynchronization or medical therapy response; stress B-lines in heart failure; hypertrophic cardiomyopathy; heart failure with preserved ejection fraction; mitral regurgitation after either transcatheter or surgical aortic valve replacement; outdoor SE in extreme physiology; right ventricular contractile reserve in repaired Tetralogy of Fallot; suspected or initial pulmonary arterial hypertension; coronary flow velocity, left ventricular elastance reserve and B-lines in known or suspected CAD; identification of subclinical familial disease in genotype-positive, phenotype- negative healthy relatives of inherited disease (such as hypertrophic cardiomyopathy). Results: We expect to recruit about 10,000 patients over a 5-year period (2016-2020), with sample sizes ranging from 5,000 for coronary flow velocity/ left ventricular elastance/ B-lines in CAD to around 250 for hypertrophic cardiomyopathy or repaired Tetralogy of Fallot. This data-base will allow to investigate technical questions such as feasibility and reproducibility of various SE parameters and to assess their prognostic value in different clinical scenarios. Conclusions: The study will create the cultural, informatic and scientific infrastructure connecting high-volume, accredited SE labs, sharing common criteria of indication, execution, reporting and image storage of SE to obtain original safety, feasibility, and outcome data in evidence-poor diagnostic fields, also outside the established core application of SE in CAD based on regional wall motion abnormalities. The study will standardize procedures, validate emerging signs, and integrate the new information with established knowledge, helping to build a next-generation SE lab without inner walls

    Quality control of B-lines analysis in stress Echo 2020

    Get PDF
    Background The effectiveness trial “Stress echo (SE) 2020” evaluates novel applications of SE in and beyond coronary artery disease. The core protocol also includes 4-site simplified scan of B-lines by lung ultrasound, useful to assess pulmonary congestion. Purpose To provide web-based upstream quality control and harmonization of B-lines reading criteria. Methods 60 readers (all previously accredited for regional wall motion, 53 B-lines naive) from 52 centers of 16 countries of SE 2020 network read a set of 20 lung ultrasound video-clips selected by the Pisa lab serving as reference standard, after taking an obligatory web-based learning 2-h module ( http://se2020.altervista.org ). Each test clip was scored for B-lines from 0 (black lung, A-lines, no B-lines) to 10 (white lung, coalescing B-lines). The diagnostic gold standard was the concordant assessment of two experienced readers of the Pisa lab. The answer of the reader was considered correct if concordant with reference standard reading ±1 (for instance, reference standard reading of 5 B-lines; correct answer 4, 5, or 6). The a priori determined pass threshold was 18/20 (≥ 90%) with R value (intra-class correlation coefficient) between reference standard and recruiting center) > 0.90. Inter-observer agreement was assessed with intra-class correlation coefficient statistics. Results All 60 readers were successfully accredited: 26 (43%) on first, 24 (40%) on second, and 10 (17%) on third attempt. The average diagnostic accuracy of the 60 accredited readers was 95%, with R value of 0.95 compared to reference standard reading. The 53 B-lines naive scored similarly to the 7 B-lines expert on first attempt (90 versus 95%, p = NS). Compared to the step-1 of quality control for regional wall motion abnormalities, the mean reading time per attempt was shorter (17 ± 3 vs 29 ± 12 min, p < .01), the first attempt success rate was higher (43 vs 28%, p < 0.01), and the drop-out of readers smaller (0 vs 28%, p < .01). Conclusions Web-based learning is highly effective for teaching and harmonizing B-lines reading. Echocardiographers without previous experience with B-lines learn quickly.info:eu-repo/semantics/publishedVersio

    Deep sequencing of viroid-derived small RNAs from grapevine provides new insights on the role of RNA silencing in plant-viroid interaction

    Get PDF
    Viroids are circular, highly structured, non-protein-coding RNAs that, usurping cellular enzymes and escaping host defense mechanisms, are able to replicate and move through infected plants. Similarly to viruses, viroid infections are associated with the accumulation of viroid-derived 21–24 nt small RNAs (vd-sRNAs) with the typical features of the small interfering RNAs characteristic of RNA silencing, a sequence-specific mechanism involved in defense against invading nucleic acids and in regulation of gene expression in most eukaryotic organisms. (GYSVd1) were sequenced by the high-throughput platform Solexa-Illumina, and the vd-sRNAs were analyzed. The large majority of HSVd- and GYSVd1-sRNAs derived from a few specific regions (hotspots) of the genomic (+) and (−) viroid RNAs, with a prevalence of those from the (−) strands of both viroids. When grouped according to their sizes, vd-sRNAs always assumed a distribution with prominent 21-, 22- and 24-nt peaks, which, interestingly, mapped at the same hotspots.These findings show that different Dicer-like enzymes (DCLs) target viroid RNAs, preferentially accessing to the same viroid domains. Interestingly, our results also suggest that viroid RNAs may interact with host enzymes involved in the RNA-directed DNA methylation pathway, indicating more complex scenarios than previously thought for both vd-sRNAs genesis and possible interference with host gene expression

    Pulmonary Congestion During Exercise Stress Echocardiography in Ischemic and Heart Failure Patients

    No full text
    BACKGROUND: Lung ultrasound detects pulmonary congestion as B-lines at rest, and more frequently, during exercise stress echocardiography (ESE).METHODS: We performed ESE plus lung ultrasound (4-site simplified scan) in 4392 subjects referred for semi-supine bike ESE in 24 certified centers in 9 countries. B-line score ranged from 0 (normal) to 40 (severely abnormal). Five different populations were evaluated: control subjects (n=103); chronic coronary syndromes (n=3701); heart failure with reduced ejection fraction (n=395); heart failure with preserved ejection fraction (n=70); ischemic mitral regurgitation &gt;= moderate at rest (n=123). In a subset of 2478 patients, follow-up information was available.RESULTS: During ESE, B-lines increased in all study groups except controls. Age, hypertension, abnormal ejection fraction, peak wall motion score index, and abnormal heart rate reserve were associated with B-lines in multivariable regression analysis. Stress B lines (hazard ratio, 2.179 [95% CI, 1.015-4.680]; P=0.046) and ejection fraction &lt;50% (hazard ratio, 2.942 [95% CI, 1.268-6.822]; P=0.012) were independent predictors of all-cause death (n=29 after a median follow-up of 29 months).CONCLUSIONS: B-lines identify the pulmonary congestion phenotype at rest, and more frequently, during ESE in ischemic and heart failure patients. Stress B-lines may help to refine risk stratification in these patients

    Hemodynamic Heterogeneity of Reduced Cardiac Reserve Unmasked by Volumetric Exercise Echocardiography

    No full text
    Background: Two-dimensional volumetric exercise stress echocardiography (ESE) provides an integrated view of left ventricular (LV) preload reserve through end-diastolic volume (EDV) and LV contractile reserve (LVCR) through end-systolic volume (ESV) changes. Purpose: To assess the dependence of cardiac reserve upon LVCR, EDV, and heart rate (HR) during ESE. Methods: We prospectively performed semi-supine bicycle or treadmill ESE in 1344 patients (age 59.8 ± 11.4 years; ejection fraction = 63 ± 8%) referred for known or suspected coronary artery disease. All patients had negative ESE by wall motion criteria. EDV and ESV were measured by biplane Simpson rule with 2-dimensional echocardiography. Cardiac index reserve was identified by peak-rest value. LVCR was the stress-rest ratio of force (systolic blood pressure by cuff sphygmomanometer/ESV, abnormal values ≤2.0). Preload reserve was defined by an increase in EDV. Cardiac index was calculated as stroke volume index * HR (by EKG). HR reserve (stress/rest ratio) <1.85 identified chronotropic incompetence. Results: Of the 1344 patients, 448 were in the lowest tertile of cardiac index reserve with stress. Of them, 303 (67.6%) achieved HR reserve <1.85; 252 (56.3%) had an abnormal LVCR and 341 (76.1%) a reduction of preload reserve, with 446 patients (99.6%) showing ≥1 abnormality. At binary logistic regression analysis, reduced preload reserve (odds ratio [OR]: 5.610; 95% confidence intervals [CI]: 4.025 to 7.821), chronotropic incompetence (OR: 3.923, 95% CI: 2.915 to 5.279), and abnormal LVCR (OR: 1.579; 95% CI: 1.105 to 2.259) were independently associated with lowest tertile of cardiac index reserve at peak stress. Conclusions: Heart rate assessment and volumetric echocardiography during ESE identify the heterogeneity of hemodynamic phenotypes of impaired chronotropic, preload or LVCR underlying a reduced cardiac reserve

    Feasibility and functional correlates of left atrial volume changes during stress echocardiography in chronic coronary syndromes

    No full text
    : An enlarged left atrial volume index (LAVI) at rest mirrors increased LA pressure and/or impairment of LA function. A cardiovascular stress may acutely modify left atrial volume (LAV) within minutes. Aim of this study was to assess the feasibility and functional correlates of LAV-stress echocardiography (SE) Out of 514 subjects referred to 10 quality-controlled labs, LAV-SE was completed in 490 (359 male, age 67 ± 12&nbsp;years) with suspected or known chronic coronary syndromes (n = 462) or asymptomatic controls (n = 28). The utilized stress was exercise in 177, vasodilator in 167, dobutamine in 146. LAV was measured with the biplane disk summation method. SE was performed with the ABCDE protocol. The intra-observer and inter-observer LAV variability were 5% and 8%, respectively. ∆-LAVI changes (stress-rest) were negatively correlated with resting LAVI (r = -&nbsp;0.271, p &lt; 0.001) and heart rate reserve (r = -.239, p &lt; 0.001). LAV-dilators were defined as those with stress-rest increase ≥ 6.8&nbsp;ml/m2, a cutoff derived from a calculated reference change value above the biological, analytical and observer variability of LAVI. LAV dilation occurred in 56 patients (11%), more frequently with exercise (16%) and dipyridamole (13%) compared to dobutamine (4%, p &lt; 0.01). At multivariable logistic regression analysis, B-lines ≥ 2 (OR: 2.586, 95% CI = 1.1293-5.169, p = 0.007) and abnormal contractile reserve (OR: 2.207, 95% CI = 1.111-4.386, p = 0.024) were associated with LAV dilation. In conclusion, LAV-SE is feasible with high success rate and low variability in patients with chronic coronary syndromes. LAV dilation is more likely with reduced left ventricular contractile reserve and pulmonary congestion
    corecore