13 research outputs found

    B-spline X-ray diffraction imaging - Rapid non-destructive measurement of die warpage in ball grid array packages

    No full text
    Next generation “More than Moore” integrated circuit (IC) technology will rely increasingly on the benefits attributable to advanced packaging (www.itrs.net [1]). In these increasingly heterogeneous systems, the individual semiconductor die is becoming much thinner (25 to 50 μm, typically) and multiple dies can be stacked upon each other. It is difficult to assess non-destructively, non-invasively and in situ the stress or warpage of the semiconductor die inside these chip packages and conventional approaches tend to monitor the warpage of the package rather than the die. This paper comprises an account of a relatively new technique, which we call B-Spline X-Ray Diffraction Imaging (B-XRDI) and its application, in this instance, to the non-destructive mapping of Si semiconductor die lattice misorientation inside wire bonded encapsulated Low-profile Fine-pitch Ball Grid Array (LFPGA) packages. B-XRDI is an x-ray diffraction imaging technique which allows the user to reconstruct from a series of section x-ray topographic images a full profile of the warpage of the silicon semiconductor die inside such a chip package. There is no requirement for pre-treatment or pre-processing of the chip package and we show that synchrotron-based BXRDI mapping of wafer warpage can be achieved with angular tilt resolutions of the order of 50 μrad ≈ 0.003° in times as short as 9–180 s (worst case X–Y spatial resolution = 100 μm) for a full 8.7 mm × 8.7 mm semiconductor die inside the fully encapsulated LFBGA packages. We confirm the usefulness of the technique by correlating our data with conventional warpage measurements performed by mechanical and interferometric profilometry and finite element modelling (FEM). We suggest that future developments will lead to real-time, or near real-time, mapping of thermomechanical stresses during chip packaging processes, which can run from bare wafer through to a fully encapsulated chip package.status: publishe

    B-Spline X-Ray Diffraction Imaging - Rapid non-destructive measurement of die warpage in ball grid array packages

    Full text link
    Next generation "More than Moore" integrated circuit (IC) technology will rely increasingly on the benefits attributable to advanced packaging (www.itrs.net [1]). In these increasingly heterogeneous systems, the individual semiconductor die is becoming much thinner (25 to 50 μm, typically) and multiple dies can be stacked upon each other. It is difficult to assess non-destructively, non-invasively and in situ the stress or warpage of the semiconductor die inside these chip packages and conventional approaches tend to monitor the warpage of the package rather than the die. This paper comprises an account of a relatively new technique, which we call B-Spline X-Ray Diffraction Imaging (B-XRDI) and its application, in this instance, to the non-destructive mapping of Si semiconductor die lattice misorientation inside wire bonded encapsulated Low-profile Fine-pitch Ball Grid Array (LFPGA) packages. B-XRDI is an x-ray diffraction imaging technique which allows the user to reconstruct from a series of section x-ray topographic images a full profile of the warpage of the silicon semiconductor die inside such a chip package. There is no requirement for pre-treatment or pre-processing of the chip package and we show that synchrotron-based B-XRDI mapping of wafer warpage can be achieved with angular tilt resolutions of the order of 50 μrad - 0.003° in times as short as 9-180 s (worst case X-Y spatial resolution = 100 μm) for a full 8.7 mm × 8.7 mm semiconductor die inside the fully encapsulated LFBGA packages. We confirm the usefulness of the technique by correlating our data with conventional warpage measurements performed by mechanical and interferometric profilometry and finite element modelling (FEM). We suggest that future developments will lead to real-time, or near real-time, mapping of thermomechanical stresses during chip packaging processes, which can run from bare wafer through to a fully encapsulated chip package

    X-ray diffraction imaging for predictive metrology of crack propagation in 450-mm diameter silicon wafers

    No full text
    The apparatus for X-ray diffraction imaging (XRDI) of 450-mm wafers, is now placed at the ANKA synchrotron radiation source in Karlsruhe, is described in the context of the drive to inspect wafers for plastic deformation or mechanical damage. It is shown that full wafer maps at high resolution can be expected to take a few hours to record. However, we show from experiments on 200-, 300-, and 450-mm wafers that a perimeter-scan on a 450-mm wafer, to pick up edge damage and edge-originated slip sources, can be achieved in just over 10 min. Experiments at the Diamond Light Source, on wafers still in their cassettes, suggest that clean-room conditions may not be necessary for such characterization. We conclude that scaling up of the 300-mm format Jordan Valley tools, together with the existing facility at ANKA, provides satisfactory capability for future XRDI analysis of 450-mm wafers.</jats:p
    corecore