3,033 research outputs found
Antimicrobial activity of cholanic acids’ stereoisomers compared to cholic acid on the test cultures of microorganisms
The paper presents the results of a study of microbiological activity 3α and 3β amino bile acids. We revealed high antimicrobial activity. The availability and range of antimicrobial activity were revealed by the method of serial dilutions in a solid nutrient medium and shown as bacteriostatic as bactericidic effects
LEETECH facility as a flexible source of low energy electrons
A new versatile facility LEETECH for detector R&D, tests and calibration is
designed and constructed. It uses electrons produced by the photoinjector PHIL
at LAL, Orsay and provides a powerful tool for wide range R&D studies of
different detector concepts delivering "mono-chromatic" samples of low energy
electrons with adjustable energy and intensity. Among other innovative
instrumentation techniques, LEETECH will be used for testing various gaseous
tracking detectors and studying new Micromegas/InGrid concept which has very
promising characteristics of spatial resolution and can be a good candidate for
particle tracking and identification. In this paper the importance and expected
characteristics of such facility based on detailed simulation studies are
addressed
Determination of the Michel Parameters rho, xi, and delta in tau-Lepton Decays with tau --> rho nu Tags
Using the ARGUS detector at the storage ring DORIS II, we have
measured the Michel parameters , , and for
decays in -pair events produced at
center of mass energies in the region of the resonances. Using
as spin analyzing tags, we find , , , , and . In addition, we report
the combined ARGUS results on , , and using this work
und previous measurements.Comment: 10 pages, well formatted postscript can be found at
http://pktw06.phy.tu-dresden.de/iktp/pub/desy97-194.p
Proceedings of the third French-Ukrainian workshop on the instrumentation developments for HEP
The reports collected in these proceedings have been presented in the third
French-Ukrainian workshop on the instrumentation developments for high-energy
physics held at LAL, Orsay on October 15-16. The workshop was conducted in the
scope of the IDEATE International Associated Laboratory (LIA). Joint
developments between French and Ukrainian laboratories and universities as well
as new proposals have been discussed. The main topics of the papers presented
in the Proceedings are developments for accelerator and beam monitoring,
detector developments, joint developments for large-scale high-energy and
astroparticle physics projects, medical applications.Comment: 3rd French-Ukrainian workshop on the instrumentation developments for
High Energy Physics, October 15-16, 2015, LAL, Orsay, France, 94 page
Supervising the Supervisors—Procedural Training and Supervision in Internal Medicine Residency
At teaching hospitals, bedside procedures (paracentesis, thoracentesis, lumbar puncture, arthrocentesis and central venous catheter insertion) are performed by junior residents and supervised by senior peers. Residents’ perceptions about supervision or how often peer supervision produces unsafe clinical situations are unknown.
To examine the experience and practice patterns of residents performing bedside procedures.
Cross-sectional e-mail survey of 653 internal medicine (IM) residents at seven California teaching hospitals.
Surveys asked questions in three areas: (1) resident experience performing procedures: numbers of procedures performed and whether they received other (e.g., simulator) training; (2) resident comfort performing and supervising procedures; (3) resident reports of their current level of supervision doing procedures, experience with complications as well as perceptions of factors that may have contributed to complications.
Three hundred sixty-seven (56%) of the residents responded. Most PGY1 residents had performed fewer than five of any of the procedures, but most PGY-3 residents had performed at least ten by the end of their training. Resident comfort for each procedure increased with the number of procedures performed (p < 0.001). Although residents reported that peer supervision happened often, they also reported high rates of supervising a procedure before feeling comfortable with proper technique. The majority of residents (64%) reported at least one complication and did not feel supervision would have prevented complications, even though many reported complications represented technique- or preparation-related problems.
Residents report low levels of comfort and experience with procedures, and frequently report supervising prior to feeling comfortable. Our findings suggest a need to examine best practices for procedural supervision of trainees
A facility to Search for Hidden Particles (SHiP) at the CERN SPS
A new general purpose fixed target facility is proposed at the CERN SPS
accelerator which is aimed at exploring the domain of hidden particles and make
measurements with tau neutrinos. Hidden particles are predicted by a large
number of models beyond the Standard Model. The high intensity of the SPS
400~GeV beam allows probing a wide variety of models containing light
long-lived exotic particles with masses below (10)~GeV/c,
including very weakly interacting low-energy SUSY states. The experimental
programme of the proposed facility is capable of being extended in the future,
e.g. to include direct searches for Dark Matter and Lepton Flavour Violation.Comment: Technical Proposa
Core components for effective infection prevention and control programmes: new WHO evidence-based recommendations
Abstract
Health care-associated infections (HAI) are a major public health problem with a significant impact on morbidity, mortality and quality of life. They represent also an important economic burden to health systems worldwide. However, a large proportion of HAI are preventable through effective infection prevention and control (IPC) measures. Improvements in IPC at the national and facility level are critical for the successful containment of antimicrobial resistance and the prevention of HAI, including outbreaks of highly transmissible diseases through high quality care within the context of universal health coverage. Given the limited availability of IPC evidence-based guidance and standards, the World Health Organization (WHO) decided to prioritize the development of global recommendations on the core components of effective IPC programmes both at the national and acute health care facility level, based on systematic literature reviews and expert consensus. The aim of the guideline development process was to identify the evidence and evaluate its quality, consider patient values and preferences, resource implications, and the feasibility and acceptability of the recommendations. As a result, 11 recommendations and three good practice statements are presented here, including a summary of the supporting evidence, and form the substance of a new WHO IPC guideline
Measurement of the ratio of branching fractions BR(B0 -> K*0 gamma)/BR(Bs0 -> phi gamma)
The ratio of branching fractions of the radiative B decays B0 -> K*0 gamma
and Bs0 -> phi gamma has been measured using 0.37 fb-1 of pp collisions at a
centre of mass energy of sqrt(s) = 7 TeV, collected by the LHCb experiment. The
value obtained is BR(B0 -> K*0 gamma)/BR(Bs0 -> phi gamma) = 1.12 +/- 0.08
^{+0.06}_{-0.04} ^{+0.09}_{-0.08}, where the first uncertainty is statistical,
the second systematic and the third is associated to the ratio of fragmentation
fractions fs/fd. Using the world average for BR(B0 -> K*0 gamma) = (4.33 +/-
0.15) x 10^{-5}, the branching fraction BR(Bs0 -> phi gamma) is measured to be
(3.9 +/- 0.5) x 10^{-5}, which is the most precise measurement to date.Comment: 15 pages, 1 figure, 2 table
Measurement of the CKM angle γ from a combination of B±→Dh± analyses
A combination of three LHCb measurements of the CKM angle γ is presented. The decays B±→D K± and
B±→Dπ± are used, where D denotes an admixture of D0 and D0 mesons, decaying into K+K−, π+π−, K±π∓, K±π∓π±π∓, K0Sπ+π−, or K0S K+K− final states. All measurements use a dataset corresponding to 1.0 fb−1 of integrated luminosity. Combining results from B±→D K± decays alone a best-fit value of
γ =72.0◦ is found, and confidence intervals are set
γ ∈ [56.4,86.7]◦ at 68% CL,
γ ∈ [42.6,99.6]◦ at 95% CL.
The best-fit value of γ found from a combination of results from B±→Dπ± decays alone, is γ =18.9◦,
and the confidence intervals
γ ∈ [7.4,99.2]◦ ∪ [167.9,176.4]◦ at 68% CL
are set, without constraint at 95% CL. The combination of results from B± → D K± and B± → Dπ±
decays gives a best-fit value of γ =72.6◦ and the confidence intervals
γ ∈ [55.4,82.3]◦ at 68% CL,
γ ∈ [40.2,92.7]◦ at 95% CL
are set. All values are expressed modulo 180◦, and are obtained taking into account the effect of D0–D0
mixing
- …