364 research outputs found
Assessment of poststress left ventricular ejection fraction by gated SPECT: comparison with equilibrium radionuclide angiocardiography
PURPOSE: We compared left ventricular (LV) ejection fraction obtained by gated SPECT with that obtained by equilibrium radionuclide angiocardiography in a large cohort of patients.
METHODS: Within 1 week, 514 subjects with suspected or known coronary artery disease underwent same-day stress-rest (99m)Tc-sestamibi gated SPECT and radionuclide angiocardiography. For both studies, data were acquired 30 min after completion of exercise and after 3 h rest.
RESULTS: In the overall study population, a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.82, p<0.0001) and after stress (r=0.83, p<0.0001). In Bland-Altman analysis, the mean differences in ejection fraction (radionuclide angiocardiography minus gated SPECT) were -0.6% at rest and 1.7% after stress. In subjects with normal perfusion (n=362), a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.72, p<0.0001) and after stress (r=0.70, p<0.0001) and the mean differences in ejection fraction were -0.9% at rest and 1.4% after stress. Also in patients with abnormal perfusion (n=152), a good correlation between the two techniques was observed both at rest (r=0.89, p<0.0001) and after stress (r=0.90, p<0.0001) and the mean differences in ejection fraction were 0.1% at rest and 2.5% after stress.
CONCLUSION: In a large study population, a good agreement was observed in the evaluation of LV ejection fraction between gated SPECT and radionuclide angiocardiography. However, in patients with perfusion abnormalities, a slight underestimation in poststress LV ejection fraction was observed using gated SPECT as compared to equilibrium radionuclide angiocardiography
Intruding implements: a pictorial review of retained surgical foreign objects in neuroradiology
Intra-cranial and spinal foreign body reactions represent potential complications of medical procedures. Their diagnosis may be challenging as they frequently show an insidious clinical presentation and can mimic other life-threatening conditions. Their pathophysiological mechanism is represented by a local inflammatory response due to retained or migrated surgical elements. Cranial interventions may be responsible for the presence of retained foreign objects represented by surgical materials (such as sponges, bone wax, and Teflon). Spinal diagnostic and therapeutic procedures, including myelography, chordotomy, vertebroplasty, and device implantation, are another potential source of foreign bodies. These reactions can also follow material migration or embolization, for example in the case of Lipiodol, Teflon, and cement vertebroplasty. Imaging exams, especially CT and MRI, have a central role in the differential diagnosis of these conditions together with patient history. Neuroradiological findings are dependent on the type of material that has been left in or migrated from the surgical area. Knowledge of these entities is relevant for clinical practice as the correct identification of foreign bodies and related inflammatory reactions, material embolisms, or migrations can be difficult. This pictorial review reports neuroradiological semeiotics and differential diagnosis of foreign body-related imaging abnormalities in the brain and spine
Neuroradiological findings in Alagille syndrome
Alagille syndrome (ALGS) is a multisystemic disease caused by mutations in genes of Notch pathway, which regulates embryonic cell differentiation and angiogenesis. Clinically, ALGS is characterized by cholestasis, cardiac defects, characteristic facial features, skeletal and ophthalmologic abnormalities. The aim of this review is to illustrate neuroradiological findings in ALGS, which are less well-known and prevalent, including cerebrovascular anomalies (such as aneurysms, dolichoectasia, Moyamoya syndrome and venous peculiarities), Chiari 1 malformation, craniosynostosis, intracranial hypertension, and vertebral anomalies (namely butterfly vertebra, hemivertebra, and craniocervical junction anomalies). Rarer cerebral midline malformations and temporal bone anomalies have also been described
Cardiac effect of thyrotoxicosis in acromegaly
Cardiac structure and function are affected both by acromegaly and hyperthyroidism. Whereas the former is mainly characterized by ventricular hypertrophy as well as diastolic and systolic impairment, the latter frequently leads to increased heart rate and enhancement of contractility and cardiac output. To further investigate this issue, we designed this two-arm study. In the first cross-sectional study, we compared echocardiography and radionuclide angiography results obtained in eight hyperthyroid acromegalic patients, eight hyperthyroid nonacromegalic patients, and eight healthy subjects. All acromegalic patients were receiving treatment for acromegaly at the onset of hyperthyroidism. In the second longitudinal study, performed in the group of acromegalic patients, we compared the cardiovascular results obtained during hyperthyroidism with the retrospective data obtained at the initial diagnosis of acromegaly and after 1-yr treatment for this disease and those prospective data obtained during the remission of hyperthyroidism. In the cross-sectional study, hyperthyroid acromegalic patients showed an increase in the left ventricular (LV) mass index (LVMi) compared to healthy and hyperthyroid controls (P < 0.05), with evidence of LVMi hypertrophy in five of them (62.5%). A significant correlation was found between LVMi and GH levels (r = 0.785; P < 0.05). The LV ejection fraction (LVEF) at rest was higher in the control hyperthyroid population than in healthy controls (P < 0.05), whereas the LVEF response to exercise was reduced in acromegalic patients (P < 0.05 vs. healthy controls). In acromegalics, the exercise-induced change in LVEF was significantly reduced compared to that in healthy controls (P < 0.001), but not to that in hyperthyroid controls (P < 0.07), being abnormal (<5% increase vs. baseline values) in six patients. Four of these six patients (66%) had elevated GH and insulin-like growth factor I levels during the treatment of acromegaly. An inverse correlation between GH and LVEF at rest (r = -0.896;P < 0.05) and at peak exercise (r = -0.950; P < 0.001) was recorded. The peak filling rate was reduced in hyperthyroid acromegalic patients compared to those in both control populations (P < 0.05). In the longitudinal study, acromegalic patients showed an increased LVMi during hyperthyroidism compared to that observed after successful treatment of acromegaly (P < 0.05); resting LVEF was increased compared to both basal (P < 0.001) and posttreatment values (P < 0.05). However, the exercise-induced change in LVEF was reduced (P < 0.05 vs. previous follow-up values). Remission of hyperthyroidism led to significant reduction of LVMi (P < 0.05) and resting LVEF (P < 0.05) and an increase in exercise-induced LVEF (P < 0.05). In light of these findings, hyperthyroidism produces a detrimental effect on the cardiovascular system of acromegalic patients, particularly in those with uncontrolled disease. Thus, control of GH and insulin-like growth factor I should be a major objective, as cardiovascular risk persists in patients with ineffective hormonal suppression, and constant endocrine and cardiovascular surveillance remain crucial steps in patient follow-up
Systematic review with radiomics quality score of cholangiocarcinoma: an EuSoMII Radiomics Auditing Group Initiative
Objectives To systematically review current research applications of radiomics in patients with cholangiocarcinoma and to assess the quality of CT and MRI radiomics studies. Methods A systematic search was conducted on PubMed/Medline, Web of Science, and Scopus databases to identify original studies assessing radiomics of cholangiocarcinoma on CT and/or MRI. Three readers with different experience levels independently assessed quality of the studies using the radiomics quality score (RQS). Subgroup analyses were performed according to journal type, year of publication, quartile and impact factor (from the Journal Citation Report database), type of cholangiocarcinoma, imaging modality, and number of patients. Results A total of 38 original studies including 6242 patients (median 134 patients) were selected. The median RQS was 9 (corresponding to 25.0% of the total RQS; IQR 1-13) for reader 1, 8 (22.2%, IQR 3-12) for reader 2, and 10 (27.8%; IQR 5-14) for reader 3. The inter-reader agreement was good with an ICC of 0.75 (95% CI 0.62-0.85) for the total RQS. All studies were retrospective and none of them had phantom assessment, imaging at multiple time points, nor performed cost-effectiveness analysis. The RQS was significantly higher in studies published in journals with impact factor > 4 (median 11 vs. 4, p = 0.048 for reader 1) and including more than 100 patients (median 11.5 vs. 0.5, p < 0.001 for reader 1). Conclusions Quality of radiomics studies on cholangiocarcinoma is insufficient based on the radiomics quality score. Future research should consider prospective studies with a standardized methodology, validation in multi-institutional external cohorts, and open science data
PET/CT without capacity limitations: a Danish experience from a European perspective
# The Author(s) 2011. This article is published with open access at Springerlink.com Objectives We report the 3-year clinical experience of a large new Danish PET/CT centre without capacity limitations in relation to national and European developments. Methods The use of PET/CT in cancer was registered from early 2006 to early 2009 to judge the impact on patient management and to compare it with national and European trends. Results 6056 PET/CT examinations were performed in 4327 patients. Activity increased by 86 examinations per month compared with the same month the year before. Referrals came primarily from oncology (23.0%), haematology (21.6%), surgery (12.6%), internal medicine (12.7%) and gynaecology (5.5%). Referral indications were diagnosis (31.3%), staging (22.3%), recurrence detection (21.2%), response evaluation (17.0%) and other (8.2%). Response from nearly 60 % of users showed that PET/CT caused a change in diagnosis and/or staging and/or treatment plan in 36.0 % of cases. During the study period, there was a steep increase in the national use of FDG and in the European use of PET/CT. Conclusions We recorded a constantly increasing use of PET/CT that caused a change in diagnosis and/or stagin
The right to food and food diversity in the Italian Constitution
Il contributo analizza la tutela apprestata dalla Costituzione italiana al diritto al cibo che, pur non essendo espressamente menzionato, viene ricavato attraverso l'analisi di principi ed azioni sottese alla nostra Carta che ne riconoscono il valore: il principio lavorista, la lotta alla povertĂ , la retribuzione del lavoratore...
- …