86 research outputs found
Minimization of phonon-tunneling dissipation in mechanical resonators
Micro- and nanoscale mechanical resonators have recently emerged as
ubiquitous devices for use in advanced technological applications, for example
in mobile communications and inertial sensors, and as novel tools for
fundamental scientific endeavors. Their performance is in many cases limited by
the deleterious effects of mechanical damping. Here, we report a significant
advancement towards understanding and controlling support-induced losses in
generic mechanical resonators. We begin by introducing an efficient numerical
solver, based on the "phonon-tunneling" approach, capable of predicting the
design-limited damping of high-quality mechanical resonators. Further, through
careful device engineering, we isolate support-induced losses and perform the
first rigorous experimental test of the strong geometric dependence of this
loss mechanism. Our results are in excellent agreement with theory,
demonstrating the predictive power of our approach. In combination with recent
progress on complementary dissipation mechanisms, our phonon-tunneling solver
represents a major step towards accurate prediction of the mechanical quality
factor.Comment: 12 pages, 4 figure
Graphene Photonics and Optoelectronics
The richness of optical and electronic properties of graphene attracts
enormous interest. Graphene has high mobility and optical transparency, in
addition to flexibility, robustness and environmental stability. So far, the
main focus has been on fundamental physics and electronic devices. However, we
believe its true potential to be in photonics and optoelectronics, where the
combination of its unique optical and electronic properties can be fully
exploited, even in the absence of a bandgap, and the linear dispersion of the
Dirac electrons enables ultra-wide-band tunability. The rise of graphene in
photonics and optoelectronics is shown by several recent results, ranging from
solar cells and light emitting devices, to touch screens, photodetectors and
ultrafast lasers. Here we review the state of the art in this emerging field.Comment: Review Nature Photonics, in pres
Electrical tuning of elastic wave propagation in nanomechanical lattices at MHz frequencies
Nanoelectromechanical systems (NEMS) that operate in the megahertz (MHz) regime allow energy transducibility between different physical domains. For example, they convert optical or electrical signals into mechanical motions and vice versa. This coupling of different physical quantities leads to frequency-tunable NEMS resonators via electromechanical non-linearities. NEMS platforms with single- or low-degrees of freedom have been employed to demonstrate quantum-like effects, such as mode cooling, mechanically induced transparency, Rabi oscillation, two-mode squeezing and phonon lasing. Periodic arrays of NEMS resonators with architected unit cells enable fundamental studies of lattice-based solid-state phenomena, such as bandgaps, energy transport, non-linear dynamics and localization, and topological properties, directly transferrable to on-chip devices. Here we describe one-dimensional, non-linear, nanoelectromechanical lattices (NEML) with active control of the frequency band dispersion in the radio-frequency domain (10–30 MHz). The design of our systems is inspired by NEMS-based phonon waveguides and includes the voltage-induced frequency tuning of the individual resonators. Our NEMLs consist of a periodic arrangement of mechanically coupled, free-standing nanomembranes with circular clamped boundaries. This design forms a flexural phononic crystal with a well-defined bandgap, 1.8 MHz wide. The application of a d.c. gate voltage creates voltage-dependent on-site potentials, which can significantly shift the frequency bands of the device. Additionally, a dynamic modulation of the voltage triggers non-linear effects, which induce the formation of a phononic bandgap in the acoustic branch, analogous to Peierls transition in condensed matter. The gating approach employed here makes the devices more compact than recently proposed systems, whose tunability mostly relies on materials’ compliance and mechanical non-linearities
Surface modification of starch based biomaterials by oxygen plasma or UV-irradiation
Radiation is widely used in biomaterials science for surface modification and sterilization. Herein, we describe the use of plasma and UV-irradiation to improve the biocompatibility of different starch-based blends in terms of cell adhesion and proliferation. Physical and chemical changes, introduced by the used methods, were evaluated by complementary techniques for surface analysis such as scanning electron microscopy, atomic force microscopy, contact angle analysis and X-ray photoelectron spectroscopy. The effect of the changed surface properties on the adhesion of osteoblast-like cells was studied by a direct contact assay. Generally, both treatments resulted in higher number of cells adhered to the modified surfaces. The importance of the improved biocompatibility resulting from the irradiation methods is further supported by the knowledge that both UV and plasma treatments can be used as cost-effective methods for sterilization of biomedical materials and devices.I. P. thanks the FCT for providing her a postdoctoral scholarship (SFRH/BPD/8491/2002). This work was partially supported by FCT, through funds from the POCTI and/or FEDER programs, The European Union funded STREP Project HIPPOCRATES (NNM-3-CT-2003-505758) and the European NoE EXPERTISSUES (NMP3-CT-2004-500283)
FIB patterning of stainless steel for the development of nano-structured stent surfaces for cardiovascular applications
Stent implantation is a percutaneous interventional procedure that mitigates vessel stenosis, providing mechanical support within the artery and as such a very valuable tool in the fight against coronary artery disease. However, stenting causes physical damage to the arterial wall. It is well accepted that a valuable route to reduce in-stent re-stenosis can be based on promoting cell response to nano-structured stainless steel (SS) surfaces such as by patterning nano-pits in SS. In this regard patterning by focused ion beam (FIB) milling offers several advantages for flexible prototyping. On the other hand FIB patterning of polycrystalline metals is greatly influenced by channelling effects and redeposition. Correlative microscopy methods present an opportunity to study such effects comprehensively and derive structure–property understanding that is important for developing improved patterning. In this chapter we present a FIB patterning protocol for nano-structuring features (concaves) ordered in rectangular arrays on pre-polished 316L stainless steel surfaces. An investigation based on correlative microscopy approach of the size, shape and depth of the developed arrays in relation to the crystal orientation of the underlying SS domains is presented. The correlative microscopy protocol is based on cross-correlation of top-view scanning electron microscopy, electron backscattering diffraction, atomic force microscopy and cross-sectional (serial) sectioning. Various FIB tests were performed, aiming at improved productivity by preserving nano-size accuracy of the patterned process. The optimal FIB patterning conditions for achieving reasonably high throughput (patterned rate of about 0.03 mm2/h) and nano-size accuracy in dimensions and shapes of the features are discussed as well
Generating and measuring the anisotropic elastic behaviour of Co thin films with oriented surface nano-strings on micro-cantilevers
In this research, the elastic behaviour of two Co thin films simultaneously deposited in an off-normal angle method was studied. Towards this end, two Si micro-cantilevers were simultaneously coated using pulsed laser deposition at an oblique angle, creating a Co nano-string surface morphology with a predetermined orientation. The selected position of each micro-cantilever during the coating process created longitudinal or transverse nano-strings. The anisotropic elastic behaviour of these Co films was determined by measuring the changes that took place in the resonant frequency of each micro-cantilever after this process of creating differently oriented plasma coatings had been completed. This differential procedure allowed us to determine the difference between the Young's modulus of the different films based on the different direction of the nano-strings. This difference was determined to be, at least, the 20% of the Young's modulus of the bulk Co
An Atomic-resolution nanomechanical mass sensor
Mechanical resonators are widely used as inertial balances to detect small
quantities of adsorbed mass through shifts in oscillation frequency[1].
Advances in lithography and materials synthesis have enabled the fabrication of
nanoscale mechanical resonators[2, 3, 4, 5, 6], which have been operated as
precision force[7], position[8, 9] and mass sensors[10, 11, 12, 13, 14, 15].
Here we demonstrate a room-temperature, carbon-nanotube-based nanomechanical
resonator with atomic mass resolution. This device is essentially a mass
spectrometer with a mass sensitivity of 1.3 times 10^-25 kg Hz^-1/2 or,
equivalently, 0.40 gold atoms Hz^-1/2. Using this extreme mass sensitivity, we
observe atomic mass shot noise, which is analogous to the electronic shot
noise[16, 17] measured in many semiconductor experiments. Unlike traditional
mass spectrometers, nanomechanical mass spectrometers do not require the
potentially destructive ionization of the test sample, are more sensitive to
large molecules, and could eventually be incorporated on a chip
Experimental realization of on-chip topological nanoelectromechanical metamaterials
Topological mechanical metamaterials translate condensed matter phenomena,
like non-reciprocity and robustness to defects, into classical platforms. At
small scales, topological nanoelectromechanical metamaterials (NEMM) can enable
the realization of on-chip acoustic components, like unidirectional waveguides
and compact delay-lines for mobile devices. Here, we report the experimental
realization of NEMM phononic topological insulators, consisting of
two-dimensional arrays of free-standing silicon nitride (SiN) nanomembranes
that operate at high frequencies (10-20 MHz). We experimentally demonstrate the
presence of edge states, by characterizing their localization and Dirac
cone-like frequency dispersion. Our topological waveguides also exhibit
robustness to waveguide distortions and pseudospin-dependent transport. The
suggested devices open wide opportunities to develop functional acoustic
systems for high-frequency signal processing applications
A phase II randomized trial comparing radiotherapy with concurrent weekly cisplatin or weekly paclitaxel in patients with advanced cervical cancer
<p>Abstract</p> <p>Purpose/Objective</p> <p>This is a prospective comparison of weekly cisplatin to weekly paclitaxel as concurrent chemotherapy with standard radiotherapy for locally advanced cervical carcinoma.</p> <p>Materials/Methods</p> <p>Between May 2000 and May 2004, 31 women with FIGO stage IB2-IVA cervical cancer or with postsurgical pelvic recurrence were enrolled into this phase II study and randomized to receive on a weekly basis either 40 mg/m<sup>2 </sup>Cisplatin (group I; 16 patients) or 50 mg/m<sup>2 </sup>paclitaxel (group II; 15 patients) concurrently with radiotherapy. Median total dose to point A was 74 Gy (range: 66-92 Gy) for group I and 66 Gy (range: 40-98 Gy) for group II. Median follow-up time was 46 months.</p> <p>Results</p> <p>Patient and tumor characteristics were similar in both groups. The mean number of chemotherapy cycles was also comparable with 87% and 80% of patients receiving at least 4 doses in groups I and II, respectively. Seven patients (44%) of group I and 8 patients (53%) of group II developed tumor recurrence. The Median Survival time was not reached for Group I and 53 months for group II. The proportion of patients surviving at 2 and 5 years was 78% and 54% for group I and 73% and 43% for group II respectively.</p> <p>Conclusions</p> <p>This small prospective study shows that weekly paclitaxel does not provide any clinical advantage over weekly cisplatin for concurrent chemoradiation for advanced carcinoma of the cervix.</p
Is There an Economical Running Technique? A Review of Modifiable Biomechanical Factors Affecting Running Economy
- …
