30 research outputs found
Determination of nutrients in seawater by segmented–flow analysis with higher analysis rate and reduced interference on ammonia
A microbore continuous-flow analyser was used to determine
ammonia, nitrite, nitrate and phosphate in seawater. Ninety
samples per hour were measured by optimizing the hydraulic
conditions and using a cadmium coil for nitrate reduction. The
analysis range was extended and the detection limit was reduced by
using two analytical ranges with automatic range-changing.
Interference from magnesium on ammonia was investigated and
reduced by using a different complexing agent. The results
correlated well with a Japanese reference method
GO-SHIP Repeat Hydrography Nutrient Manual: The Precise and Accurate Determination of Dissolved Inorganic Nutrients in Seawater, Using Continuous Flow Analysis Methods
The GO-SHIP nutrient manual covers all aspects of nutrient analysis from basic sample collection and storage, specifically for Continuous Flow analysis using an Auto-Analyzer, and describes some specific nutrient methods for Nitrate, Nitrite, Silicate, Phosphate and Ammonium that are in use by many laboratories carrying out at-sea analysis and repeat hydrography sections across the world. The focus is on segmented flow analyzers not flow injection analyzers. It also covers laboratory best practices including quality control and quality assurance (QC/QA) procedures to obtain the best results, and suggests protocols for the use of reference materials (RM) and certified reference materials (CRMs)
Recommendations for the Determination of Nutrients in Seawater to High Levels of Precision and Inter-Comparability using Continuous Flow Analysers
The Global Ocean Ship-based Hydrographic Investigations Program (GO-SHIP) brings together scientists with interests in physical oceanography, the carbon cycle, marine biogeochemistry and ecosystems, and other users and collectors of ocean interior data to develop a sustained global network of hydrographic sections as part of the Global Ocean Climate Observing System. A series of manuals and guidelines are being produced by GO-SHIP which update those developed by the World Ocean Circulation Experiment (WOCE) in the early 1990s. Analysis of the data collected in WOCE suggests that improvements are needed in the collection of nutrient data if they are to be used for determining change within the ocean interior. Production of this manual is timely as it coincides with the development of reference materials for nutrients in seawater (RMNS). These RMNS solutions will be produced in sufficient quantities and be of sufficient quality that they will provide a basis for improving the consistency of nutrient measurements both within and between cruises.
This manual is a guide to suggested best practice in performing nutrient measurements at sea. It provides a detailed set of advice on laboratory practice for all the procedures surrounding the use of 1
gas-segmented continuous flow analysers (CFA) for the determination of dissolved nutrients (usually ammonium, nitrate, nitrite, phosphate and silicate) at sea. It does not proscribe the use of a particular instrument or related chemical method as these are well described in other publications.
The manual provides a brief introduction to the CFA method, the collection and storage of samples, considerations in the preparation of reagents and the calibrations of the system. It discusses how RMNS solutions can be used to “track” the performance of a system during a cruise and between cruises. It provides a format for the meta-data that need to be reported along side the sample data at the end of a cruise so that the quality of the reported data can be evaluated and set in context relative to other data sets.
Most importantly the central manual is accompanied by a set of nutrient standard operating procedures (NSOPs) that provide detailed information on key procedures that are necessary if best quality data are to be achieved consistently. These cover sample collection and storage, an example NSOP for the use of a CFA system at sea, high precision preparation of calibration solutions, assessment of the true calibration blank, checking the linearity of a calibration and the use of internal and externally prepared reference solutions for controlling the precision of data during a cruise and between cruises. An example meta-data report and advice on the assembly of the quality control and statistical data that should form part of the meta-data report are also given
2008 Inter-laboratory Comparison Study of a Reference Material for Nutrients in Seawater
Autoclaved natural seawater collected in the North Pacific Ocean was used as a reference material for nutrients in seawater (RMNS) during an inter-laboratory comparison (I/C) study conducted in 2008. This study was a follow-up to previous studies conducted in 2003 and 2006. A set of six samples was distributed to each of 58 laboratories in 15 countries around the globe, and results were returned by 54 of those laboratories (15 countries). The homogeneities of samples used in the 2008 I/C study, based on analyses for three determinants, were improved compared to those of samples used in the 2003 and 2006 I/C studies.
Results of these I/C studies indicate that most of the participating laboratories have an analytical technique for nutrients that is sufficient to provide data of high comparability. The differences between reported concentrations from the same laboratories in the 2006 and 2008 I/C studies for the same batch of RMNS indicate that most of the laboratories have been maintaining internal comparability for two years.
Thus, with the current high level of performance in the participating laboratories, the use of a common reference material and the adaptation of an internationally accepted
nutrient scale system would increase comparability among laboratories worldwide, and
the use of a certified reference material would establish traceability.
In the 2008 I/C study we observed a problem of non-linearity of the instruments of the participating laboratories similar to that observed among the laboratories in the 2006
I/C study. This problem of non-linearity should be investigated and discussed to improve comparability for the full range of nutrient concentrations. For silicate comparability in particular, we see relatively larger consensus standard deviations than those for nitrate and phosphate
Songs by Ethelbert Nevin: summer longings
https://digitalmaine.com/blue_hill_documents/1174/thumbnail.jp