35 research outputs found

    Using trained dogs and organic semi-conducting sensors to identify asymptomatic and mild SARS-CoV-2 infections: an observational study

    Get PDF
    BACKGROUND: A rapid, accurate, non-invasive diagnostic screen is needed to identify people with SARS-CoV-2 infection. We investigated whether organic semi-conducting (OSC) sensors and trained dogs could distinguish between people infected with asymptomatic or mild symptoms, and uninfected individuals, and the impact of screening at ports-of-entry. METHODS: Odour samples were collected from adults, and SARS-CoV-2 infection status confirmed using RT-PCR. OSC sensors captured the volatile organic compound (VOC) profile of odour samples. Trained dogs were tested in a double-blind trial to determine their ability to detect differences in VOCs between infected and uninfected individuals, with sensitivity and specificity as the primary outcome. Mathematical modelling was used to investigate the impact of bio-detection dogs for screening. RESULTS: About, 3921 adults were enrolled in the study and odour samples collected from 1097 SARS-CoV-2 infected and 2031 uninfected individuals. OSC sensors were able to distinguish between SARS-CoV-2 infected individuals and uninfected, with sensitivity from 98% (95% CI 95–100) to 100% and specificity from 99% (95% CI 97–100) to 100%. Six dogs were able to distinguish between samples with sensitivity ranging from 82% (95% CI 76–87) to 94% (95% CI 89–98) and specificity ranging from 76% (95% CI 70–82) to 92% (95% CI 88–96). Mathematical modelling suggests that dog screening plus a confirmatory PCR test could detect up to 89% of SARS-CoV-2 infections, averting up to 2.2 times as much transmission compared to isolation of symptomatic individuals only. CONCLUSIONS: People infected with SARS-CoV-2, with asymptomatic or mild symptoms, have a distinct odour that can be identified by sensors and trained dogs with a high degree of accuracy. Odour-based diagnostics using sensors and/or dogs may prove a rapid and effective tool for screening large numbers of people. Trial Registration NCT04509713 (clinicaltrials.gov)

    The effect of Sn on autoclave corrosion performance and corrosion mechanisms in Zr-Sn-Nb alloys

    Get PDF
    The desire to improve the corrosion resistance of Zr cladding material for hig h burn-up has resulted in a general trend among fuel manufacturers to develop alloys with reduced levels of Sn. While commonly accepted, the reason for the improved corrosion performance observed for low-tin zirconium alloys in high-temperature aqueous environments remains unclear. High-energy synchrotron X-ray diffraction was used to characterize the oxides formed by autoclave exposure on Zr-Sn-Nb alloys with tin concentration ranging from 0.01 to 0.92 wt.%. The alloys studied included the commercial alloy ZIRLO® (ZIRLO® is a registered trademark of Westinghouse Electric Company LLC in the USA and may be registered in other countries throughout the world. All rights reserved. Unauthorized use is strictly prohibited.) and two variants of ZIRLO with significantly lower tin levels, referred to here as A-0.6Sn and A-0.0Sn. The nature of the oxide grown on tube samples from each alloy was investigated via cross-sectional scanning electron microscopy. Atom probe analysis of ZIRLO demonstrated that the tin present in the alloy passes into the oxide as it forms, with no significant difference in the Sn/Zr ratio between the two. Synchrotron X-ray diffraction measurements on the oxides formed on each alloy revealed that the monoclinic and tetragonal oxide phases display highly compressive in-plane residual stresses with the magnitudes dependent on the phase and alloy. The amount of tetragonal phase present and, more importantly, the level of tetragonal-to-monoclinic phase transformation both decrease with decreasing tin levels, suggesting that tin is a tetragonal oxide phase stabilizing element. It is proposed that in Zr-Nb-Sn alloys with low Sn, the tetragonal phase is mainly stabilized by very small grain size and therefore remains stable throughout the corrosion process. In contrast, alloys with higher tin levels can in addition grow larger, stress stabilized, tetragonal grains that become unstable as the corrosion front continues to grow further inwards and stresses in the existing oxide relax. © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved

    Studies regarding corrosion mechanisms in zirconium alloys

    No full text
    Understanding the key corrosion mechanisms in a light water reactor primary water environment is critical to developing and exploiting improved zirconium alloy fuel cladding. In this paper, we report recent research highlights from a new collaborative research programme involving 3 U.K. universities and 5 partners from the nuclear industry. A major part of our strategy is to use the most advanced analytical tools to characterise the oxide and metal/oxide interface microstructure, residual stresses, as well as the transport properties of the oxide. These techniques include three-dimensional atom probe (3DAP), advanced transmission electron microscopy (TEM), synchrotron X-ray diffraction, Raman spectroscopy, and in situ electro-impedance spectroscopy. Synchrotron X-ray studies have enabled the characterisation of stresses, tetragonal phase fraction, and texture in the oxide as well as the stresses in the metal substrate. It was found that in the thick oxide (here, Optimized-ZIRLO, a trademark of the Westinghouse Electric Company, tested at 415°C in steam) a significant stress profile can be observed, which cannot be explained by metal substrate creep alone but that local delamination of the oxide layers due to crack formation must also play an important role. It was also found that the oxide stresses in the monoclinic and tetragonal phases grown on Zircaloy-4 (autoclave testing at 360°C) first relax during the pre-transition stage. Just before transition, the compressive stress in the monoclinic phase suddenly rises, which is interpreted as indirect evidence of significant tetragonal to monoclinic phase transformation taking place at this stage. TEM studies of pre- and post-transition oxides grown on ZIRLO, a trademark of the Westinghouse Electric Company, have used Fresnel contrast imaging to identify nano-sized pores along the columnar grain boundaries that form a network interconnected once the material goes through transition. The development of porosity during transition was further confirmed by in situ electrochemical impedance spectroscopy (EIS) studies. 3DAP analysis was used to identify a ZrO sub-oxide layer at the metal/oxide interface and to establish its three-dimensional morphology. It was possible to demonstrate that this sub-oxide structure develops with time and changes dramatically around transition. This observation was further confirmed by in situ EIS studies, which also suggest thinning of the sub-oxide/barrier layer around transition. Finally, 3DAP analysis was used to characterise segregation of alloying elements near the metal/oxide interface and to establish that the corroding metal near the interface (in this case ZIRLO) after 100 days at 360°C displays a substantially different chemistry and microstructure compared to the base alloy with Fe segregating to the Zr/ZrO interface

    An immunoassay for human D dimer using monoclonal antibodies

    No full text
    Monoclonal antibodies (MAb) were raised against human D dimer. The hybridomas were screened with a solid phase enzyme immunoassay against D dimer and fibrinogen degradation products. Among the panel of MAb identified, two distinct patterns emerged; the majority belonging to a panspecific class reacting against epitopes present on both D dimer and fibrinogen degradation product Dcate and a monospecific class reacting with determinants apparently present only on D dimer. A number of MAb were further characterised for their ability to specifically capture antigen in a solid phase enzyme immunoassay and assays were developed which have a sensitivity of 10 ng/ml for D dimer or crosslinked fibrin derivatives and may be suitable for detection of crosslinked derivatives in serum and plasma samples in a clinical situation