25 research outputs found
PM<sub>10</sub>-bound trace elements in pan-European urban atmosphere
Although many studies have discussed the impact of Europe's air quality, very limited research focused on the detailed phenomenology of ambient trace elements (TEs) in PM10 in urban atmosphere. This study compiled long-term (2013–2022) measurements of speciation of ambient urban PM10 from 55 sites of 7 countries (Switzerland, Spain, France, Greece, Italy, Portugal, UK), aiming to elucidate the phenomenology of 20 TEs in PM10 in urban Europe. The monitoring sites comprised urban background (UB, n = 26), traffic (TR, n = 10), industrial (IN, n = 5), suburban background (SUB, n = 7), and rural background (RB, n = 7) types. The sampling campaigns were conducted using standardized protocols to ensure data comparability. In each country, PM10 samples were collected over a fixed period using high-volume air samplers. The analysis encompassed the spatio-temporal distribution of TEs, and relationships between TEs at each site. Results indicated an annual average for the sum of 20 TEs of 90 ± 65 ng/m3, with TR and IN sites exhibiting the highest concentrations (130 ± 66 and 131 ± 80 ng/m3, respectively). Seasonal variability in TEs concentrations, influenced by emission sources and meteorology, revealed significant differences (p < 0.05) across all monitoring sites. Estimation of TE concentrations highlighted distinct ratios between non-carcinogenic and carcinogenic metals, with Zn (40 ± 49 ng/m3), Ti (21 ± 29 ng/m3), and Cu (23 ± 35 ng/m3) dominating non-carcinogenic TEs, while Cr (5 ± 7 ng/m3), and Ni (2 ± 6 ng/m3) were prominent among carcinogenic ones. Correlations between TEs across diverse locations and seasons varied, in agreement with differences in emission sources and meteorological conditions. This study provides valuable insights into TEs in pan-European urban atmosphere, contributing to a comprehensive dataset for future environmental protection policies
The fingerprint of the summer 2018 drought in Europe on ground-based atmospheric CO2 measurements
During the summer of 2018, a widespread drought developed over Northern and Central Europe. The increase in temperature and the reduction of soil moisture have influenced carbon dioxide (CO2) exchange between the atmosphere and terrestrial ecosystems in various ways, such as a reduction of photosynthesis, changes in ecosystem respiration, or allowing more frequent fires. In this study, we characterize the resulting perturbation of the atmospheric CO2 seasonal cycles. 2018 has a good coverage of European regions affected by drought, allowing the investigation of how ecosystem flux anomalies impacted spatial CO2 gradients between stations. This density of stations is unprecedented compared to previous drought events in 2003 and 2015, particularly thanks to the deployment of the Integrated Carbon Observation System (ICOS) network of atmospheric greenhouse gas monitoring stations in recent years. Seasonal CO2 cycles from 48 European stations were available for 2017 and 2018.The UK sites were funded by the UK Department of Business,
Energy and Industrial Strategy (formerly the Department of Energy
and Climate Change) through contracts TRN1028/06/2015 and
TRN1537/06/2018. The stations at the ClimaDat Network in
Spain have received funding from the ‘la Caixa’ Foundation, under
agreement 2010-002624
Organic markers and OC source apportionment for seasonal variations of PM2.5 at 5 rural sites in France
International audienc
Manipulation of lignin composition in transgenic poplar trees by antisense strategy
International audienc
A whole-body physiologically based pharmacokinetic (WB-PBPK) model of ciprofloxacin : a step towards predicting bacterial killing at sites of infection.
The purpose of this study was to develop a whole-body physiologically based pharmacokinetic (WB-PBPK) model for ciprofloxacin for ICU patients, based on only plasma concentration data. In a next step, tissue and organ concentration time profiles in patients were predicted using the developed model. The WB-PBPK model was built using a non-linear mixed effects approach based on data from 102 adult intensive care unit patients. Tissue to plasma distribution coefficients (Kp) were available from the literature and used as informative priors. The developed WB-PBPK model successfully characterized both the typical trends and variability of the available ciprofloxacin plasma concentration data. The WB-PBPK model was thereafter combined with a pharmacokinetic-pharmacodynamic (PKPD) model, developed based on in vitro time-kill data of ciprofloxacin and Escherichia coli to illustrate the potential of this type of approach to predict the time-course of bacterial killing at different sites of infection. The predicted unbound concentration-time profile in extracellular tissue was driving the bacterial killing in the PKPD model and the rate and extent of take-over of mutant bacteria in different tissues were explored. The bacterial killing was predicted to be most efficient in lung and kidney, which correspond well to ciprofloxacin's indications pneumonia and urinary tract infections. Furthermore, a function based on available information on bacterial killing by the immune system in vivo was incorporated. This work demonstrates the development and application of a WB-PBPK-PD model to compare killing of bacteria with different antibiotic susceptibility, of value for drug development and the optimal use of antibiotics
Genetic engeneering of poplar trees may be used to improve their tolerance toward insects or to alter their lignin metabolism
International audienc
Understanding lignin biosynthesis in poplar through genetic engineering
International audienc
Secretome analysis of Phanerochaete chrysosporium strains CIRM-BRFM41 grown on softwood
 Abstract Proteomic analysis was performed to determine and differentiate the composition of the secretomes of Phanerochaete chrysosporium CIRM-BRFM41, a peroxidase hypersecretory strain grown under ligninolytic conditions and on softwood chips under biopulping conditions. Extracellular proteins from both cultures were analyzed by bidimensional gel electrophoresis and matrix-assisted laser desorption/ionization time-of-flight tandem mass spectrometry. A total of 37 spots were identified. The secretome in liquid synthetic medium comprised mainly peroxidases, while several wood-degrading enzymes and enzymes involved in fungal metabolism were detected in biopulping cultures on softwood. This prompted an analysis of the impact of secretome modulation in the presence of softwood chips. Biotreated wood was submitted to kraft cooking and chemical bleaching using chlorine dioxide. The fungal pre-treatment led to a significant increase in pulp yield and a better bleachability of the pulp. This bleachability improvement could be explained by the production of specific lignocellulose-degrading enzymes
Evaluation and optimization of ICOS atmosphere station data as part of the labeling process
The Integrated Carbon Observation System (ICOS) is a pan-European research infrastructure which provides harmonized and high-precision scientific data on the carbon cycle and the greenhouse gas budget. All stations have to undergo a rigorous assessment before being labeled, i.e., receiving approval to join the network. In this paper, we present the labeling process for the ICOS atmosphere network through the 23 stations that were labeled between November 2017 and November 2019. We describe the label-ing steps, as well as the quality controls, used to verify that the ICOS data (CO2, CH4, CO and meteorological measurements) attain the expected quality level defined within ICOS. To ensure the quality of the greenhouse gas data, three to four calibration gases and two target gases are measured: one target two to three times a day, the other gases twice a month. The data are verified on a weekly basis, and tests on the station sampling lines are performed twice a year. From these high-quality data, we conclude that regular calibrations of the CO2, CH4 and CO analyzers used here (twice a month) are important in particular for carbon monoxide (CO) due to the analyzer's variability and that reducing the number of calibration injections (from four to three) in a calibration sequence is possible, saving gas and extending the calibration gas lifespan. We also show that currently, the on-site water vapor correction test does not deliver quantitative results possibly due to environmental factors. Thus the use of a drying system is strongly recommended. Finally, the mandatory regular intake line tests are shown to be useful in detecting artifacts and leaks, as shown here via three different examples at the stations.Peer reviewe