4,632 research outputs found

    THE DEVELOPMENT OF CHILDREN’S IDENTIFICATION: A CROSS-CULTURAL COMPARISON BETWEEN BULGARIA, ITALY AND UKRAINE

    Get PDF
    The study presented here analyses the development of self-categorisation, national, European and local identification of Bulgarian, Ukrainian and Italian children and adolescents growing up in Bulgaria, Ukraine and Italy. The sample consisted of 541 children aged 6, 9, 12 and 15 years. It was found that national, European and local identifications differ in the three national groups. It is argued that the cognitive-developmental account of the development of national identification is unable to explain the patterns of findings which were obtained. The social identity theory, however, is able to explain the different patterns of importance given to the different identifications by the three national groups

    SENSE: A comparison of photon detection efficiency and optical crosstalk of various SiPM devices

    Full text link
    This paper describes a comparison of photon detection efficiency and optical crosstalk measurements performed by three partners: Geneva University, Catania Observatory and Nagoya University. The measurements were compared for three different SiPM devices with different active areas: from 9 mm2mm^2 up to 93.6 mm2mm^2 produced by Hamamatsu. The objective of this work is to establish the measurements and analysis procedures for calculating the main SiPM parameters and their precision. This work was done in the scope of SENSE project which aims to build roadmap for the last developments in field of sensors for low light level detection

    Vitamin C inhibits platelet expression of CD40 ligand

    Get PDF
    Upon stimulation with agonists, platelets express CD40 ligand (CD40L), a transmembrane protein implicated in the initiation and progression of atherosclerotic disease. We have recently discovered that oxidative stress plays a major role in platelet CD40L expression. In this study, we sought to determine whether vitamin C, a known antioxidant, is able to influence platelet CD40L expression. In vitro experiments were done by stimulating platelets with collagen in the presence or absence of vitamin C (50-100 mu M) or vehicle as control. An in vivo study was done in 10 healthy subjects who were randomized to intravenous infusion of placebo or 1 g vitamin C for 45 min in a crossover design. At the end of infusion platelet CD40L and O2- were measured. The in vitro study demonstrated that vitamin C dose dependently inhibited platelet CD40L expression without affecting agonist-induced platelet aggregation. In subjects treated with placebo no changes of platelet CD40L and O2- were observed; conversely, vitamin C infusion caused a significant and parallel decrease of platelet O2- (-70%, P < 0.001) and CD40L (-68%, P < 0.001). Platelet aggregation was not modified by either treatment. This study suggests that water-soluble antioxidants, which scavenge superoxide radicals, may reduce platelet CD40L expression. (c) 2005 Elsevier Inc. All rights reserved

    Short-range correlations in low-lying nuclear excited states

    Get PDF
    The electromagnetic transitions to various low-lying excited states of 16O, 48Ca and 208Pb are calculated within a model which considers the short-range correlations. In general the effects of the correlations are small and do not explain the required quenching to describe the data.Comment: 6 pages, 2 postscript figures, 1 tabl

    Molecular signature of retinoic acid treatment in acute promyelocytic leukemia

    Get PDF
    Acute promyelocytic leukemia (APL) is a distinct subtype of acute myeloid leukemia characterized by a block of differentiation at the promyelocytic stage. APL patients respond to pharmacological concentrations of all-trans retinoic acid ( RA) and disease remission correlates with terminal differentiation of leukemic blasts. The PML/RAR oncogenic transcription factor is responsible for both the pathogenesis of APL and for its sensitivity to RA. In order to identify physiological targets of RA therapy, we analysed gene expression profiles of RA-treated APL blasts and found 1056 common target genes. Comparing these results to those obtained in RA-treated U937 cell lines revealed that transcriptional response to RA is largely dependent on the expression of PML/RAR. Several genes involved in the control of differentiation and stem cell renewal are early targets of RA regulation, and may be important effectors of RA response. Modulation of chromatin modifying genes was also observed, suggesting that specific structural changes in local chromatin domains may be required to promote RA-mediated differentiation. Computational analysis of upstream genomic regions in RA target genes revealed nonrandom distribution of transcription factor binding sites, indicating that specific transcriptional regulatory complexes may be involved in determining RA response

    Development of a strategy for calibrating the novel SiPM camera of the SST-1M telescope proposed for the Cherenkov Telescope Array

    Full text link
    CTA will comprise a sub-array of up to 70 small size telescopes (SSTs) at the southern array. The SST-1M project, a 4 m-diameter Davies Cotton telescope with 9 degrees FoV and a 1296 pixels SiPM camera, is designed to meet the requirements of the next generation ground based gamma-ray observatory CTA in the energy range above 3 TeV. Silicon photomultipliers (SiPM) cameras of gamma-ray telescopes can achieve good performance even during high night sky background conditions. Defining a fully automated calibration strategy of SiPM cameras is of great importance for large scale production validation and online calibration. The SST-1M sub-consortium developed a software compatible with CTA pipeline software (CTApipe). The calibration of the SST-1M camera is based on the Camera Test Setup (CTS), a set of LED boards mounted in front of the camera. The CTS LEDs are operated in pulsed or continuous mode to emulate signal and night sky background respectively. Continuous and pulsed light data analysis allows us to extract single pixel calibration parameters to be used during CTA operation.Comment: All CTA contributions at arXiv:1709.0348

    Inclusive electron scattering in a relativistic Green function approach

    Get PDF
    A relativistic Green function approach to the inclusive quasielastic (e,e') scattering is presented. The single particle Green function is expanded in terms of the eigenfunctions of the nonhermitian optical potential. This allows one to treat final state interactions consistently in the inclusive and in the exclusive reactions. Numerical results for the response functions and the cross sections for different target nuclei and in a wide range of kinematics are presented and discussed in comparison with experimental data.Comment: 12 pages, 7 figures, REVTeX

    Joint Elastic Side-Scattering Lidar and Raman Lidar Measurements of Aerosol Optical Properties in South East Colorado

    Get PDF
    We describe an experiment, located in south-east Colorado, USA, that measured aerosol optical depth profiles using two Lidar techniques. Two independent detectors measured scattered light from a vertical UV laser beam. One detector, located at the laser site, measured light via the inelastic Raman backscattering process. This is a common method used in atmospheric science for measuring aerosol optical depth profiles. The other detector, located approximately 40km distant, viewed the laser beam from the side. This detector featured a 3.5m2 mirror and measured elastically scattered light in a bistatic Lidar configuration following the method used at the Pierre Auger cosmic ray observatory. The goal of this experiment was to assess and improve methods to measure atmospheric clarity, specifically aerosol optical depth profiles, for cosmic ray UV fluorescence detectors that use the atmosphere as a giant calorimeter. The experiment collected data from September 2010 to July 2011 under varying conditions of aerosol loading. We describe the instruments and techniques and compare the aerosol optical depth profiles measured by the Raman and bistatic Lidar detectors.Comment: 34 pages, 16 figure

    Performance of a small size telescope (SST-1M) camera for gamma-ray astronomy with the Cherenkov Telescope Array

    Full text link
    The foreseen implementations of the Small Size Telescopes (SST) in CTA will provide unique insights into the highest energy gamma rays offering fundamental means to discover and under- stand the sources populating the Galaxy and our local neighborhood. Aiming at such a goal, the SST-1M is one of the three different implementations that are being prototyped and tested for CTA. SST-1M is a Davies-Cotton single mirror telescope equipped with a unique camera technology based on SiPMs with demonstrated advantages over classical photomultipliers in terms of duty-cycle. In this contribution, we describe the telescope components, the camera, and the trigger and readout system. The results of the commissioning of the camera using a dedicated test setup are then presented. The performances of the camera first prototype in terms of expected trigger rates and trigger efficiencies for different night-sky background conditions are presented, and the camera response is compared to end-to-end simulations.Comment: All CTA contributions at arXiv:1709.0348
    corecore