167 research outputs found

    Transition to quantitative faecal immunochemical testing from guaiac faecal occult blood testing in a fully rolled-out population-based national bowel screening programme

    Get PDF
    Objective: Faecal immunochemical tests (FIT) are replacing guaiac faecal occult blood tests (FOBT) in colorectal cancer (CRC) screening. Data from the first year of FIT screening were compared with those from FOBT screening and assumptions based on a pilot evaluation of FIT.Design: Data on uptake, positivity, positive predictive value (PPV) for CRC and higher-risk adenoma from participants in the first year of the FIT-based Scottish Bowel Screening Programme (n=919 665), with a threshold of 80 μg Hb/g faeces, were compared with those from the penultimate year of the FOBT-based programme (n=862 165) and those from the FIT evaluation (n=66 225).Results: Overall, uptake of FIT was 63.9% compared with 56.4% for FOBT. Positivity was 3.1% and 2.2% with FIT and FOBT; increases were seen in both sexes, and across age range and deprivation. More CRC and adenomas were detected by FIT, but the PPV for CRC was less (5.2% with FIT and 6.4% with FOBT). However, for higher-risk adenoma, PPV was greater with FIT (24.3% with FIT and 19.3% with FOBT). In the previous FIT evaluation, uptake was 58.5% with FIT compared with 54.0% with FOBT; positivity was 2.5% with FIT and 2.0% with FOBT.Conclusion: Transition to FIT from FOBT produced higher uptake and positivity with lower PPV for CRC and higher PPV for adenoma. The FIT pilot evaluation underestimated uptake and positivity. Introducing FIT at the same threshold as the evaluation caused a 67.2% increase in colonoscopy demand instead of a predicted 10%.</p

    Changes in prevalence of faecal occult blood positivity over time

    Get PDF
    Objectives: Changes in the prevalence of faecal occult blood test positivity over time have not been previously reported, but could have important implications. This study examined the positivity of the initial guaiac faecal occult blood test, a surrogate marker for colorectal bleeding, in participants aged 50 in a national bowel screening programme.Methods: Data from the Scottish Bowel Screening Programme were used to study the initial positivity of the guaiac faecal occult blood test between 2007 and 2017. Positive predictive values of the testing process for colorectal cancer and adenoma were assessed over the same time period.Results: Across Scotland, the initial guaiac faecal occult blood test positivity increased from 4.1 to 10.8%. In NHS Grampian and NHS Fife, two of the three NHS Boards which began roll-out of screening in 2007, it increased from 4.0 to 10.9%. In the Scottish Bowel Screening Programme, the positive predictive value declined from 11.0 to 6.6% for colorectal cancer and increased from 31.6 to 39.8% for adenoma.Conclusions: In the Scottish programme over a decade, initial guaiac faecal occult blood test positivity increased in participants aged 50. This may be associated with changes in lifestyle and might have implications for screening clinical outcomes, including positive predictive value

    Do faecal test-based colorectal cancer screening pilots provide data that are reflected in subsequent programmes? Evidence from interval cancer proportions

    Get PDF
    OBJECTIVE: Guidelines on colorectal cancer (CRC) screening with guaiac faecal occult blood tests (gFOBTs) and faecal immunochemical tests (FITs) include the need for a pilot before a programme is introduced. Interval cancers (ICs), cancers arising after a negative screening test result but before the next scheduled invite, are important indicators of programme quality. Our aim was to compare IC in the gFOBT-based Scottish Bowel Screening Programme (SBoSP), a FIT-based pilot, and the FIT-based SBoSP, to assess if the pilot provided data that was reflected in the subsequent programme. DESIGN: The IC proportions (ICPs) data ([IC/(IC + screen detected CRC)] x 100) from the penultimate year of the gFOBT-based SBoSP, the 6-month pilot and the first year of the FIT-based SBoSP were compared. To ensure appropriate comparison, these data were only from the two pilot NHS Boards. RESULTS: For all participants, and females and males, the ICPs were very similar in the gFOBT-based SBoSP and the pilot. The faecal haemoglobin concentration (f-Hb) threshold for the pilot was set at ≥80 μg Hb/g faeces. However, in marked contrast, in the FIT-based SBoSP, at the same threshold, the ICPs were lower. In all three groups, the ICPs were higher in females than in males. CONCLUSIONS: Data on variables in pilots, including ICP, can be informative, but only if variables such as FIT system are held consistent between pilot and programme. Lowering the f-Hb threshold for females to give the same ICP as males might be a strategy to minimise sex inequality

    Faecal Haemoglobin Estimated by Faecal Immunochemical Tests:An Indicator of Systemic Inflammation with Real Clinical Potential

    Get PDF
    Multimorbidity is the major cause of ill-health and premature death in developed countries. The ability to identify individuals at risk of developing chronic disease, particularly multimorbidity, reliably, and simply, and to identify undiagnosed disorders, is vital to reducing the global burden of disease. This narrative review, the first of recent studies, demonstrates that raised faecal haemoglobin concentration (f-Hb) is associated with increased all-cause and cause-specific mortality and with longer-term conditions including diabetes, hypertension, cardiovascular disease, and psoriasis, and with probable intake of particulate matter. We and others have hypothesized that elevated f-Hb (measured using a faecal immunochemical test) has considerable potential to identify individuals at risk of, or who already have, early stage, undiagnosed chronic disease. If f-Hb does prove to be an effective biomarker for chronic disease and multimorbidity, individuals with detectable f-Hb, but without an obvious source of gastrointestinal blood loss, could benefit from further assessment and early intervention. To test this hypothesis rigorously, longitudinal data-linkage methodology is required linking colorectal cancer screening data, and data on patients presenting with lower gastrointestinal symptoms, with routinely collected health information.<br/

    Comparison with first round findings of faecal haemoglobin concentrations and clinical outcomes in the second round of a biennial faecal immunochemical test based colorectal cancer screening programme

    Get PDF
    OBJECTIVE: How faecal haemoglobin concentrations (f-Hb) vary from one round to the next in a colorectal cancer (CRC) screening programme, and relate to colonoscopy findings, are unknown. Our aim was to use data from the first two rounds of the faecal immunochemical test (FIT) based Scottish Bowel Screening Programme (SBoSP) to explore these issues. METHODS: Faecal haemoglobin concentration (f-Hb) percentiles in the second round were compared with those in the first when the first round yielded a negative FIT result (<80 µg Hb/g faeces), a positive FIT but no colonoscopy, CRC, all adenoma, and a negative colonoscopy. In addition, the outcomes in the first and second rounds were compared. RESULTS: The profiles of f-Hb in the first and second rounds differed in (a) those who had had a negative FIT result in the first round and (b) those in whom neoplastic pathology had been found. In contrast, the pattern of difference between profiles in those who had had a negative colonoscopy was very similar to that in those in whom an adenoma had been found. In addition, the risk of CRC being diagnosed in the second round after a negative colonoscopy in the first was 3.0%, not very different to that after a negative test result (4.9%). CONCLUSIONS: Adenomas may be rarely the cause of a positive FIT result. An alternative explanation as to why these are detected using FIT is required. In addition, a negative colonoscopy for a positive FIT result does not rule out the finding of significant neoplastic pathology in the next round

    Improved use of faecal immunochemical tests for haemoglobin in the Scottish bowel screening programme

    Get PDF
    Objectives: This study aimed to develop a risk-scoring model in the Scottish Bowel Screening Programme incorporating faecal haemoglobin concentration with other risk factors for colorectal cancer.Methods: Data were collected for all individuals invited to participate in the Scottish Bowel Screening Programme between November 2017 and March 2018 including faecal haemoglobin concentration, age, sex, National Health Service Board, socioeconomic status, and screening history. Linkage with The Scottish Cancer Registry identified all screening participants diagnosed with colorectal cancer. Logistic regression was performed to identify which factors demonstrated significant association with colorectal cancer and could be used in the development of a risk-scoring model.Results: Of 232,076 screening participants, 427 had colorectal cancer: 286 diagnosed following a screening colonoscopy and 141 arising after a negative screening test result giving an interval cancer proportion of 33.0%. Only faecal haemoglobin concentration and age showed a statistically significant association with colorectal cancer. Interval cancer proportion increased with age and was higher in women (38.1%) than men (27.5%). If positivity in women were mirrored in men at each age quintile interval cancer proportion would still have remained higher in women (33.2%). Moreover, an additional 1201 colonoscopies would be required to detect 11 colorectal cancers.Conclusions: Development of a risk scoring model using early data from the Scottish Bowel Screening Programme was not feasible due to most variables showing insignificant association with colorectal cancer. Tailoring the faecal haemoglobin concentration threshold according to age could help to diminish some of the disparity in interval cancer proportion between women and men. Strategies to achieve sex equality using faecal haemoglobin concentration thresholds depend considerably on which variable is selected for equivalency and this requires further exploration.</p

    Variation in changes in the incidence of colorectal cancer by age and association with screening uptake: an observational study

    Get PDF
    Objectives: In developed countries, the incidence of colorectal cancer (CRC) has declined in the over 50 years age group but increased in younger people. We studied CRC incidence by age and the influence of screening uptake.Design: Age-standardised and sex-standardised incidences for CRC from 1997 to 2017 were obtained from the Scottish Cancer Registry (SCR). In addition, linkage between the Scottish Bowel Screening Database and the SCR allowed investigation of any association between screening participation and CRC incidence.Setting: Scotland and the Scottish Bowel Screening Programme, in which guaiac faecal occult blood test screening was piloted from March 2000 and fully rolled by December 2009.Participants: From the introduction of screening in 2000 through to 2017, 2 395 172 were invited to participate, of whom 1 487 999 participated at least once.Main outcome measures: Incidence of CRC.Results: In the screening age range (50-74 years), CRC incidence peaked at 156.5 cases per 100 000 in 2010 after full roll-out of screening across Scotland but fell to 123.9 per 100 000 in 2017. However, under 50 years, there was a rise from 5.3 cases per 100 000 in 2000 to 6.8 per 100 000 in 2017. When CRC incidence was examined in those who had been offered screening, incidence fell in the participant group more than in the non-participant group after roll-out of screening was complete. Analysis of cumulative incidence demonstrated that CRC incidence in the participant group remained consistently below that of the non-participant from around 7 years of follow-up.Conclusions: The incidence of CRC in Scotland has declined in the over 50 years age group but increased in younger people. It is likely that population screening has contributed to the reduction in CRC incidence in the over 50 years age group.</p

    Faecal haemoglobin distributions by sex, age, deprivation and geographical region:consequences for colorectal cancer screening strategies

    Get PDF
    Faecal immunochemical tests for haemoglobin (FIT) are becoming widely used in colorectal cancer (CRC) screening and assessment of symptomatic patients. Faecal haemoglobin concentration (f-Hb) thresholds are used to guide subsequent investigation. We established the distributions of f-Hb in a large screening population by sex, age, deprivation and geography. Single estimates of f-Hb were documented for all individuals participating in the first 18 months of the Scottish Bowel Screening Programme (SBoSP). The distributions of f-Hb were generated for all participants, all men and women, and men and women by age quintile and deprivation quintile. Distributions were also generated by geographical region for all participants, men and women, and by deprivation. Comparisons of f-Hb distributions with those found in a pilot evaluation of FIT and three other countries were performed. f-Hb was documented for 887,248 screening participants, 422,385 men and 464,863 women. f-Hb varied by sex, age, deprivation quintile and geographical region. The f-Hb distributions by sex and age differed between the SBoSP and the pilot evaluation and the three other countries. f-Hb is higher in men than in women and increases with age and deprivation in both sexes. f-Hb also varies by geographical region, independently of deprivation, and by country. The f-Hb distribution estimated by pilot evaluation may not represent the population distribution. Decision limits have advantages over reference intervals. Use of partitioned f-Hb thresholds for further investigation, based on the data generated, has advantages and disadvantages, as do risk scores based on a spectrum of influencing variables.</p

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Use of Intravenous Albumin: A Guideline From the International Collaboration for Transfusion Medicine Guidelines.

    Get PDF
    BACKGROUND: Albumin is used commonly across a wide range of clinical settings to improve hemodynamics, to facilitate fluid removal, and to manage complications of cirrhosis. The International Collaboration for Transfusion Medicine Guidelines developed guidelines for the use of albumin in patients requiring critical care, undergoing cardiovascular surgery, undergoing kidney replacement therapy, or experiencing complications of cirrhosis. STUDY DESIGN AND METHODS: Cochairs oversaw the guideline development process and the panel included researchers, clinicians, methodologists, and a patient representative. The evidence informing this guideline arises from a systematic review of randomized clinical trials and systematic reviews, in which multiple databases were searched (inception through November 23, 2022). The panel reviewed the data and formulated the guideline recommendations using Grading of Recommendations Assessment, Development, and Evaluation methodology. The guidelines were revised after public consultation. RESULTS: The panel made 14 recommendations on albumin use in adult critical care (three recommendations), pediatric critical care (one recommendation), neonatal critical care (two recommendations), cardiovascular surgery (two recommendations), kidney replacement therapy (one recommendation), and complications of cirrhosis (five recommendations). Of the 14 recommendations, two recommendations had moderate certainty of evidence, five recommendations had low certainty of evidence, and seven recommendations had very low certainty of evidence. Two of the 14 recommendations suggested conditional use of albumin for patients with cirrhosis undergoing large-volume paracentesis or with spontaneous bacterial peritonitis. Twelve of 14 recommendations did not suggest albumin use in a wide variety of clinical situations where albumin commonly is transfused. INTERPRETATION: Currently, few evidence-based indications support the routine use of albumin in clinical practice to improve patient outcomes. These guidelines provide clinicians with actionable recommendations on the use of albumin
    corecore