3 research outputs found

    Validation of the LUMIPULSE automated immunoassay for the measurement of core AD biomarkers in cerebrospinal fluid

    Get PDF
    Altres ajuts: Swedish Research Council (#2017-00915); Alzheimer Drug Discovery Foundation (ADDF), USA (#RDAPB-201809-2016615); Swedish Alzheimer Foundation (#AF-742881); Hjärnfonden, Sweden (#FO2017-0243); Swedish State Under the Agreement Between the Swedish Government and the County Councils, the ALF-Agreement (#ALFGBG-715986); National Program of Sustainability II (MEYS CR); Ministry of Health of the Czech Republic (grant no. 19-04-00560); ZonMW (part of the Dutch national 'Deltaplan for Dementia'; Selfridges Group Foundation; National Institutes of Health, USA (grant number 5R01NS104147-02); Alzheimerfonden (AF-930934); Åhléns-stiftelsen; Stiftelsen för Gamla tjänarinnor; Canadian Institutes of Health Research (CIHR) (MOP-11-51-31; RFN 152985, 159815, 162303); Canadian Consortium of Neurodegeneration and Aging (CCNA; MOP-11-51-31 -team 1); Weston Brain Institute, the Alzheimer's Association (NIRG-12-92090, NIRP-12-259245); Brain Canada Foundation (CFI Project 34874; 33397); Fonds de Recherche du Québec - Santé (FRQS; Chercheur Boursier, 2020-VICO-279314); Wallenberg Scholar supported by grants, Swedish Research Council (#2018-02532); Swedish State Support for Clinical Research (#ALFGBG-720931); Alzheimer Drug Discovery Foundation (ADDF), USA (#201809-2016862); Dementia Research Institute at UCL.Objectives: The core cerebrospinal fluid (CSF) biomarkers; total tau (tTau), phospho-tau (pTau), amyloid β 1-42 (Aβ 1-42), and the Aβ 1-42/Aβ 1-40 ratio have transformed Alzheimer's disease (AD) research and are today increasingly used in clinical routine laboratories as diagnostic tools. Fully automated immunoassay instruments with ready-to-use assay kits and calibrators has simplified their analysis and improved reproducibility of measurements. We evaluated the analytical performance of the fully automated immunoassay instrument LUMIPULSE G (Fujirebio) for measurement of the four core AD CSF biomarkers and determined cutpoints for AD diagnosis. Methods: Comparison of the LUMIPULSE G assays was performed with the established INNOTEST ELISAs (Fujirebio) for hTau Ag, pTau 181, β-amyloid 1-42, and with V-PLEX Plus Aβ Peptide Panel 1 (6E10) (Meso Scale Discovery) for Aβ 1-42/Aβ 1-40, as well as with a LC-MS reference method for Aβ 1-42. Intra- and inter-laboratory reproducibility was evaluated for all assays. Clinical cutpoints for Aβ 1-42, tTau, and pTau was determined by analysis of three cohorts of clinically diagnosed patients, comprising 651 CSF samples. For the Aβ 1-42/Aβ 1-40 ratio, the cutpoint was determined by mixture model analysis of 2,782 CSF samples. Results: The LUMIPULSE G assays showed strong correlation to all other immunoassays (r>0.93 for all assays). The repeatability (intra-laboratory) CVs ranged between 2.0 and 5.6%, with the highest variation observed for β-amyloid 1-40. The reproducibility (inter-laboratory) CVs ranged between 2.1 and 6.5%, with the highest variation observed for β-amyloid 1-42. The clinical cutpoints for AD were determined to be 409 ng/L for total tau, 50.2 ng/L for pTau 181, 526 ng/L for β-amyloid 1-42, and 0.072 for the Aβ 1-42/Aβ 1-40 ratio. Conclusions: Our results suggest that the LUMIPULSE G assays for the CSF AD biomarkers are fit for purpose in clinical laboratory practice. Further, they corroborate earlier presented reference limits for the biomarkers

    Detection of subarachnoid haemorrhage with spectrophotometry of cerebrospinal fluid - a comparison of two methods

    No full text
    OBJECTIVES: Spectrophotometric absorption curve analysis of cerebrospinal fluid (CSF) for oxyhaemoglobin and bilirubin is necessary to accurately diagnose subarachnoid haemorrhage (SAH) in patients with typical symptoms but with negative findings on X-ray examinations. In this study, we evaluated the performance of two methods for interpreting absorption curves; one method from the United Kingdom National External Quality Assessment Service (UK-NEQAS) and the other from the national quality assurance programme in Sweden (Equalis). METHODS: Consecutive absorbance curves (n=336) were interpreted with two different methods, and their performance was compared to the diagnosis as stated in the patient records. RESULTS: The UK-NEQAS method displayed equal sensitivity to the Equalis method, but the specificity of the UK-NEQAS method was significantly higher than the Equalis method resulting in fewer false positive results. For UK-NEQAS, a positive predictive value (PPV) of 84.6% and a negative predictive value (NPV) of 99.7% were observed, whereas the Equalis method had a PPV of 27.5% and an NPV of 99.7%. CONCLUSIONS: The semi-automated method based on the guidelines from UK-NEQAS provides an efficient and correct interpretation of absorbance curves with short turn-around times. We propose using this method for the routine interpretation of CSF spectrophotometric curves

    Detection of subarachnoid haemorrhage with spectrophotometry of cerebrospinal fluid : a comparison of two methods

    No full text
    Objectives: Spectrophotometric absorption curve analysis of cerebrospinal fluid (CSF) for oxyhaemoglobin and bilirubin is necessary to accurately diagnose subarachnoid haemorrhage (SAH) in patients with typical symptoms but with negative findings on X-ray examinations. In this study, we evaluated the performance of two methods for interpreting absorption curves; one method from the United Kingdom National External Quality Assessment Service (UK-NEQAS) and the other from the national quality assurance programme in Sweden (Equalis). Methods: Consecutive absorbance curves (n=336) were interpreted with two different methods, and their performance was compared to the diagnosis as stated in the patient records. Results: The UK-NEQAS method displayed equal sensitivity to the Equalis method, but the specificity of the UK-NEQAS method was significantly higher than the Equalis method resulting in fewer false positive results. For UK-NEQAS, a positive predictive value (PPV) of 84.6% and a negative predictive value (NPV) of 99.7% were observed, whereas the Equalis method had a PPV of 27.5% and an NPV of 99.7%. Conclusions: The semi-automated method based on the guidelines from UK-NEQAS provides an efficient and correct interpretation of absorbance curves with short turn-around times. We propose using this method for the routine interpretation of CSF spectrophotometric curves
    corecore