33 research outputs found

    Toll-Like Receptors: The Key of Immunotherapy in MSCs

    Get PDF
    Human mesenchymal stem cells (MSCs) are potential candidates for various applications in the fields of immunotherapy. Their multilineage differentiation capability and immune modulatory features allow their prospective application for the management of different immunological circumstances. However, the local microenvironment, in addition to the source of the MSCs can control diverse biological features of the cells. Indeed, throughout their therapeutic application, MSCs may interact with their microenvironment through their expressed toll-like-receptors (TLRs), producing immune modulating reactions. Stimulation of MSCs before or within the potential treatment procedures with distinct TLR ligands may assist as an effective step controlling the biological function of the MSCs as needed in different therapeutic stages of the disease

    IL-1/TNF- α

    Get PDF
    Cytokines play major roles in tissue destruction/repair. The present study investigates proliferative and osteogenic differentiation potentials of gingival mesenchymal stem/progenitor cells (G-MSCs), influenced by IL-1/TNF-α inflammatory/anti-inflammatory conditions. Human G-MSCs were isolated, characterized, and cultured in basic medium (control group, M1), in basic medium with IL-1ÎČ, TNF-α, and IFN-Îł (inflammatory group, M2) and with IL-1ra/TNF-αi added to M2 (anti-inflammatory group, M3). MTT tests at days 1, 3, and 7 and CFU assay at day 12 were conducted. Osteogenic differentiation was analyzed by bone-specific transcription factors (RUNX2), alkaline phosphatase (ALP), type I collagen (Col-I), osteopontin (OPN), and osteonectin (ON) expression at days 1, 3, 7, and 14 and Alizarin red staining at day 14. At day 3, the control group showed the highest cell numbers. At day 7, cell numbers in inflammatory and anti-inflammatory group outnumbered the control group. At day 12, CFUs decreased in the inflammatory and anti-inflammatory groups, with altered cellular morphology. The anti-inflammatory group demonstrated elevated bone-specific transcription factors at 14 days. After 14 days of osteogenic induction, calcified nodules in the anti-inflammatory group were higher compared to control and inflammatory groups. For regeneration, initial inflammatory stimuli appear essential for G-MSCs’ proliferation. With inflammatory persistence, this positive effect perishes and is followed by a short-term stimulatory one on osteogenesis. At this stage, selective anti-inflammatory intervention could boost G-MSCs’ differentiation

    Gingival Mesenchymal Stem/Progenitor Cells: A Unique Tissue Engineering Gem

    Get PDF
    The human gingiva, characterized by its outstanding scarless wound healing properties, is a unique tissue and a pivotal component of the periodontal apparatus, investing and surrounding the teeth in their sockets in the alveolar bone. In the last years gingival mesenchymal stem/progenitor cells (G-MSCs), with promising regenerative and immunomodulatory properties, have been isolated and characterized from the gingival lamina propria. These cells, in contrast to other mesenchymal stem/progenitor cell sources, are abundant, readily accessible, and easily obtainable via minimally invasive cell isolation techniques. The present review summarizes the current scientific evidence on G-MSCs’ isolation, their characterization, the investigated subpopulations, the generated induced pluripotent stem cells- (iPSC-) like G-MSCs, their regenerative properties, and current approaches for G-MSCs’ delivery. The review further demonstrates their immunomodulatory properties, the transplantation preconditioning attempts via multiple biomolecules to enhance their attributes, and the experimental therapeutic applications conducted to treat multiple diseases in experimental animal models in vivo. G-MSCs show remarkable tissue reparative/regenerative potential, noteworthy immunomodulatory properties, and primary experimental therapeutic applications of G-MSCs are very promising, pointing at future biologically based therapeutic techniques, being potentially superior to conventional clinical treatment modalities

    The efficacy of an extraoral scavenging device on reducing aerosol particles ≀ 5 ”m during dental aerosol-generating procedures: an exploratory pilot study in a university setting

    No full text
    Objective/aim!#!To identify small particle concentrations (eight categories: ≀0.1 ”m × ≀5.0 ”m) induced by aerosol-generating procedures (AGPs; high-speed tooth preparation, ultrasonic scaling; air polishing) under high-flow suction with a 16-mm intraoral cannula with and without an additional mobile extraoral scavenger (EOS) device during student training.!##!Materials and methods!#!Twenty tests were performed (16.94 m!##!Results!#!Mean ΔPN (SD) ranged between -8.65E+06 (2.86E+07) counts/m!##!Discussion!#!A greater reduction in the number of smaller particles generated by the EOS device was found for high-speed tooth preparation. Low ΔPN by all AGPs demonstrated the efficacy of high-flow suction.!##!Conclusions!#!The additional use of an EOS device should be carefully considered when performing treatments, such as high-speed tooth preparation, that generate particularly small particles when more people are present and all other protective options have been exhausted

    Resin infiltration of fissure caries with various techniques of pretreatment in vitro

    Get PDF
    The resin infiltration technique might be used for occlusal caries lesions in order to arrest their progression. This in vitro study evaluated the influence of various modifications of the infiltration technique on the penetration abilities of the infiltrant into occlusal lesions. Extracted human molars and premolars (n = 140) with non-cavitated white spot lesions were randomly allocated to 7 groups. As control, specimens were etched with 15% hydrochloric acid (HCl) gel for 120 s and resin infiltrated for 180 s (Icon; DMG). As modification HCl gel reduced in surface tension and viscosity with and without abrasives was applied using 3 different types of brushes either to oscillate or rub the HCl gel onto the enamel surface. The median maximum lesion depth was 1,232 ”m (interquartile range 882-1,513). Compared with the control procedure [23% (16/50)] a higher percentage penetration was observed if the HCl gel was mixed with a small amount of abrasives were rubbed into the fissures using a modified brush with stiff bristles that were adjusted to the fissure relief for either 120 s [100% (64/100)] or 30 s [98% (61/100); p < 0.05; Mann-Whitney test]. All other experimental treatments resulted in penetration results in-between. It can be concluded that the use of an abrasive HCl gel in conjunction with a modified brush mostly enhances resin infiltration into fissure caries lesions

    The accuracy of the auto-stop function of different endodontic devices in detecting the apical constriction

    No full text
    Abstract Background Electronic apex locators (EALs) are modern devices used to determine the working length during root canal preparation. The newest endodontic motors provide an integrated EAL with auto-stop function to prevent instrumentation beyond the predefined working length during rotary root canal preparation. The aim of this study was to compare the accuracy of the auto-stop function of the VDW.Gold RECIPROC motor (VDW, Munich, Germany), the EndoPilot motor (Schlumbohm, Brokstedt, Germany) and the manual measurement with Raypex 6 (VDW, Munich, Germany) to detect the apical constriction (AC). Methods Ninety human teeth were chosen and randomly assigned to three experimental groups (30 teeth each): VDW.Gold RECIPROC motor continuous measuring (RCM), EndoPilot continuous measuring (ECM) and Raypex 6 manual measuring (RMM). When the measurement file reached the AC, the file was fixed in the tooth. The tooth was embedded in acrylic resin and the root tip was exposed, so that the histologic structure of the root canal and the file tip was visible for microscopic analysis. Afterwards, the distance of the file tip to the AC (DAC) was automatically computed with a specially developed software tool. Results The mean DAC were −13.18 Όm (SD 88.46 Όm) for RMM, −22.70 Όm (SD 91.57 Όm) for RCM and 18.74 Όm (SD 88.11 Όm) for ECM. The differences were not statistically significant (P = 0.181). The rates for instrumentation beyond the AC were not statistically different (Chi2 = 4.753, p = 0.096). Conclusions All measurement methods showed a high accuracy in detecting the AC. The auto-stop function of these endodontic motors is a reliable addition to the endodontic armamentarium
    corecore