787 research outputs found
Cerebral haemodynamics during experimental intracranial hypertension.
Intracranial hypertension is a common final pathway in many acute neurological conditions. However, the cerebral haemodynamic response to acute intracranial hypertension is poorly understood. We assessed cerebral haemodynamics (arterial blood pressure, intracranial pressure, laser Doppler flowmetry, basilar artery Doppler flow velocity, and vascular wall tension) in 27 basilar artery-dependent rabbits during experimental (artificial CSF infusion) intracranial hypertension. From baseline (∼9 mmHg; SE 1.5) to moderate intracranial pressure (∼41 mmHg; SE 2.2), mean flow velocity remained unchanged (47 to 45 cm/s; p = 0.38), arterial blood pressure increased (88.8 to 94.2 mmHg; p < 0.01), whereas laser Doppler flowmetry and wall tension decreased (laser Doppler flowmetry 100 to 39.1% p < 0.001; wall tension 19.3 to 9.8 mmHg, p < 0.001). From moderate to high intracranial pressure (∼75 mmHg; SE 3.7), both mean flow velocity and laser Doppler flowmetry decreased (45 to 31.3 cm/s p < 0.001, laser Doppler flowmetry 39.1 to 13.3%, p < 0.001), arterial blood pressure increased still further (94.2 to 114.5 mmHg; p < 0.001), while wall tension was unchanged (9.7 to 9.6 mmHg; p = 0.35).This animal model of acute intracranial hypertension demonstrated two intracranial pressure-dependent cerebroprotective mechanisms: with moderate increases in intracranial pressure, wall tension decreased, and arterial blood pressure increased, while with severe increases in intracranial pressure, an arterial blood pressure increase predominated. Clinical monitoring of such phenomena could help individualise the management of neurocritical patients.The authors would acknowledge Dr Hugh Richards and Dr Stefan Piechnik who contributed to data collection. JD is supported by a Woolf Fisher scholarship. GVV is supported by an A.G. Leventis Foundation Scholarship, and a Charter Studentship from St Edmund’s College, Cambridge. XYL is supported by Bill Gates Scholarship, and DC is supported by a Cambridge Commonwealth, European & International Trust Scholarship (University of Cambridge).This is the author accepted manuscript. The final version is available from SAGE via https://doi.org/10.1177/0271678X1663906
Combined lung and brain ultrasonography for an individualized “brain-protective ventilation strategy” in neurocritical care patients with challenging ventilation needs
When intracranial hypertension and severe lung damage coexist in the same clinical scenario, their management poses a difficult challenge, especially as concerns mechanical ventilation management. The needs of combined lung and brain protection from secondary damage may conflict, as ventilation strategies commonly used in patients with ARDS are potentially associated with an increased risk of intracranial hypertension. In particular, the use of positive end-expiratory pressure, recruitment maneuvers, prone positioning, and protective lung ventilation can have undesirable effects on cerebral physiology: they may positively or negatively affect intracranial pressure, based on the final repercussions on PaO2and cerebral perfusion pressure (through changes in cardiac output, mean arterial pressure, venous return, PaO2and PaCO2), also according to the baseline conditions of cerebral autoregulation. Lung ultrasound (LUS) and brain ultrasound (BUS, as a combination of optic nerve sheath diameter assessment and cerebrovascular Doppler ultrasound) have independently proven their potential in respectively monitoring lung aeration and brain physiology at the bedside. In this narrative review, we describe how the combined use of LUS and BUS on neurocritical patients with demanding mechanical ventilation needs can contribute to ventilation management, with the aim of a tailored “brain-protective ventilation strategy.
Effects of Prone Position and Positive End-Expiratory Pressure on Noninvasive Estimators of ICP: A Pilot Study.
BACKGROUND: Prone positioning and positive end-expiratory pressure can improve pulmonary gas exchange and respiratory mechanics. However, they may be associated with the development of intracranial hypertension. Intracranial pressure (ICP) can be noninvasively estimated from the sonographic measurement of the optic nerve sheath diameter (ONSD) and from the transcranial Doppler analysis of the pulsatility (ICPPI) and the diastolic component (ICPFVd) of the velocity waveform. METHODS: The effect of the prone positioning and positive end-expiratory pressure on ONSD, ICPFVd, and ICPPI was assessed in a prospective study of 30 patients undergoing spine surgery. One-way repeated measures analysis of variance, fixed-effect multivariate regression models, and receiver operating characteristic analyses were used to analyze numerical data. RESULTS: The mean values of ONSD, ICPFVd, and ICPPI significantly increased after change from supine to prone position. Receiver operating characteristic analyses demonstrated that, among the noninvasive methods, the mean ONSD measure had the greatest area under the curve signifying it is the most effective in distinguishing a hypothetical change in ICP between supine and prone positioning (0.86±0.034 [0.79 to 0.92]). A cutoff of 0.43 cm was found to be a best separator of ONSD value between supine and prone with a specificity of 75.0 and a sensitivity of 86.7. CONCLUSIONS: Noninvasive ICP estimation may be useful in patients at risk of developing intracranial hypertension who require prone positioning.DC and MC are partially supported by NIHR Brain Injury Healthcare Technology Co-operative, Cambridge, UK. JD is supported by a Woolf Fisher Scholarship (NZ)
The importance of monitoring cerebral oxygenation in non brain injured patients
Over the past few years, the use of non-invasive neuromonitoring in non-brain injured patients has increased, as a result of the recognition that many of these patients are at risk of brain injury in a wide number of clinical scenarios and therefore may benefit from its application which allows interventions to prevent injury and improve outcome. Among these, are post cardiac arrest syndrome, sepsis, liver failure, acute respiratory failure, and the perioperative settings where in the absence of a primary brain injury, certain groups of patients have high risk of neurological complications. While there are many neuromonitoring modalities utilized in brain injured patients, the majority of those are either invasive such as intracranial pressure monitoring, require special skill such as transcranial Doppler ultrasonography, or intermittent such as pupillometry and therefore unable to provide continuous monitoring. Cerebral oximetry using Near infrared Spectroscopy, is a simple non invasive continuous measure of cerebral oxygenation that has been shown to be useful in preventing cerebral hypoxemia both within the intensive care unit and the perioperative settings. At present, current recommendations for standard monitoring during anesthesia or in the general intensive care concentrate mainly on hemodynamic and respiratory monitoring without specific indications regarding the brain, and in particular, brain oximetry. The aim of this manuscript is to provide an up-to-date overview of the pathophysiology and applications of cerebral oxygenation in non brain injured patients as part of non-invasive multimodal neuromonitoring in the early identification and treatment of neurological complications in this population
Oxygen targets and 6-month outcome after out of hospital cardiac arrest: a pre-planned sub-analysis of the targeted hypothermia versus targeted normothermia after Out-of-Hospital Cardiac Arrest (TTM2) trial
Background: Optimal oxygen targets in patients resuscitated after cardiac arrest are uncertain. The primary aim of this study was to describe the values of partial pressure of oxygen values (PaO2) and the episodes of hypoxemia and hyperoxemia occurring within the first 72 h of mechanical ventilation in out of hospital cardiac arrest (OHCA) patients. The secondary aim was to evaluate the association of PaO2 with patients' outcome.
Methods: Preplanned secondary analysis of the targeted hypothermia versus targeted normothermia after OHCA (TTM2) trial. Arterial blood gases values were collected from randomization every 4 h for the first 32 h, and then, every 8 h until day 3. Hypoxemia was defined as PaO2 300 mmHg. Mortality and poor neurological outcome (defined according to modified Rankin scale) were collected at 6 months.
Results: 1418 patients were included in the analysis. The mean age was 64 ± 14 years, and 292 patients (20.6%) were female. 24.9% of patients had at least one episode of hypoxemia, and 7.6% of patients had at least one episode of severe hyperoxemia. Both hypoxemia and hyperoxemia were independently associated with 6-month mortality, but not with poor neurological outcome. The best cutoff point associated with 6-month mortality for hypoxemia was 69 mmHg (Risk Ratio, RR = 1.009, 95% CI 0.93-1.09), and for hyperoxemia was 195 mmHg (RR = 1.006, 95% CI 0.95-1.06). The time exposure, i.e., the area under the curve (PaO2-AUC), for hyperoxemia was significantly associated with mortality (p = 0.003).
Conclusions: In OHCA patients, both hypoxemia and hyperoxemia are associated with 6-months mortality, with an effect mediated by the timing exposure to high values of oxygen. Precise titration of oxygen levels should be considered in this group of patients.
Trial registration: clinicaltrials.gov NCT02908308 , Registered September 20, 2016.
Keywords: Cardiac arrest; Hyperoxemia; Hypoxemia; Mortality; Neurological outcom
Ventilation management and outcomes in out-of-hospital cardiac arrest: a protocol for a preplanned secondary analysis of the TTM2 trial
IntroductionMechanical ventilation is a fundamental component in the management of patients post cardiac arrest. However, the ventilator settings and the gas-exchange targets used after cardiac arrest may not be optimal to minimise post-anoxic secondary brain injury. Therefore, questions remain regarding the best ventilator management in such patients.Methods and analysisThis is a preplanned analysis of the international randomised controlled trial, targeted hypothermia versus targeted normothermia after out-of-hospital cardiac arrest (OHCA)–target temperature management 2 (TTM2). The primary objective is to describe ventilatory settings and gas exchange in patients who required invasive mechanical ventilation and included in the TTM2 trial. Secondary objectives include evaluating the association of ventilator settings and gas-exchange values with 6 months mortality and neurological outcome. Adult patients after an OHCA who were included in the TTM2 trial and who received invasive mechanical ventilation will be eligible for this analysis. Data collected in the TTM2 trial that will be analysed include patients’ prehospital characteristics, clinical examination, ventilator settings and arterial blood gases recorded at hospital and intensive care unit (ICU) admission and daily during ICU stay.Ethics and disseminationThe TTM2 study has been approved by the regional ethics committee at Lund University and by all relevant ethics boards in participating countries. No further ethical committee approval is required for this secondary analysis. Data will be disseminated to the scientific community by abstracts and by original articles submitted to peer-reviewed journals.Trial registration numberNCT02908308
Plasma exchange in the intensive care unit: a narrative review
In this narrative review, we discuss the relevant issues of therapeutic plasma exchange (TPE) in critically ill patients. For many conditions, the optimal indication, device type, frequency, duration, type of replacement fluid and criteria for stopping TPE are uncertain. TPE is a potentially lifesaving but also invasive procedure with risk of adverse events and complications and requires close monitoring by experienced teams. In the intensive care unit (ICU), the indications for TPE can be divided into (1) absolute, well-established, and evidence-based, for which TPE is recognized as first-line therapy, (2) relative, for which TPE is a recognized second-line treatment (alone or combined) and (3) rescue therapy, where TPE is used with a limited or theoretical evidence base. New indications are emerging and ongoing knowledge gaps, notably regarding the use of TPE during critical illness, support the establishment of a TPE registry dedicated to intensive care medicine
Non-invasive technology for brain monitoring: definition and meaning of the principal parameters for the International PRactice On TEChnology neuro-moniToring group (I-PROTECT)
Technologies for monitoring organ function are rapidly advancing, aiding physicians in the care of patients in both operating rooms (ORs) and intensive care units (ICUs). Some of these emerging, minimally or non-invasive technologies focus on monitoring brain function and ensuring the integrity of its physiology. Generally, the central nervous system is the least monitored system compared to others, such as the respiratory, cardiovascular, and renal systems, even though it is a primary target in most therapeutic strategies. Frequently, the effects of sedatives, hypnotics, and analgesics are entirely unpredictable, especially in critically ill patients with multiple organ failure. This unpredictability exposes them to the risks of inadequate or excessive sedation/hypnosis, potentially leading to complications and long-term negative outcomes. The International PRactice On TEChnology neuro-moniToring group (I-PROTECT), comprised of experts from various fields of clinical neuromonitoring, presents this document with the aim of reviewing and standardizing the primary non-invasive tools for brain monitoring in anesthesia and intensive care practices. The focus is particularly on standardizing the nomenclature of different parameters generated by these tools. The document addresses processed electroencephalography, continuous/quantitative electroencephalography, brain oxygenation through near-infrared spectroscopy, transcranial Doppler, and automated pupillometry. The clinical utility of the key parameters available in each of these tools is summarized and explained. This comprehensive review was conducted by a panel of experts who deliberated on the included topics until a consensus was reached. Images and tables are utilized to clarify and enhance the understanding of the clinical significance of non-invasive neuromonitoring devices within these medical settings
- …
