3,380 research outputs found

    Haemodynamic changes during propofol induction in dogs: New findings and approach of monitoring

    Get PDF
    Abstract Background Propofol is one of the most widely used injectable anaesthetic agents in veterinary practice. Cardiovascular effects related to propofol use in dogs remain less well defined. The main objective of this study was to evaluate the haemodynamic changes during induction of general anaesthesia with propofol in healthy dogs, by a beat-to-beat continuous monitoring. All dogs were premedicated with intramuscular acepromazine (0.015 mg/kg) and methadone (0.15 mg/kg). Transthoracic echocardiography was used to measure the velocity time integral (VTI) of the left ventricular outflow tract. A syringe driver, programmed to deliver propofol 5 mg/kg over 30 s followed by a continuous infusion of 25 mg/kg/h, was used to induce and maintain anaesthesia. From the initiation of propofol administration, heart rate (HR) and mean invasive arterial blood pressure (MAP) were recorded every 5 s for 300 s, while aortic blood flow was continuously recorded and stored for 300 S. maximum cardiovascular depression was defined the lowest MAP (MAP_Tpeak) recorded during the monitored interval. VTI and VTI*HR were calculated at 0, 30, 90, 120, 150 and 300 s post administration of propofol, and at MAP_Tpeak. Haemodynamic effects of propofol in relation to plasma and biophase concentrations were also evaluated by pharmacokinetics simulation. Results The median (range) HR was significantly higher (p = 0.006) at the moment of maximum hemodynamic depression (Tpeak) [105(70–148) bpm] compared with pre-induction values (T0) [65(50–120) bpm]. The median (range) MAP was significantly lower (p < 0.001) at Tpeak [61(51–69) mmHg] compared with T0 [88(72–97) mmHg]. The median (range) VTI and VTI*HR were similar at the two time points [11.9(8.1–17.3) vs 13,3(9,4-16,5) cm, and 1172(806–1554) vs 1002(630–1159) cm*bpm, respectively]. Conclusions Induction of anaesthesia with propofol causes a drop of arterial pressure in healthy dogs, however cardiac output is well maintained by compensatory chronotropic response. The magnitude of MAP_Tpeak may be strictly related with propofol plasma concentration

    Ultrasound-guided hook-wire localization for surgical excision of non-palpable superficial inguinal lymph nodes in dogs: A pilot study

    Get PDF
    The evaluation of loco-regional lymph nodes (LN) plays an important prognostic role and assists the clinical decision making in canine cancer patients. Excision of non-palpable LN can be challenging. The aim of the study was to evaluate surgical time, successful excision rate and surgical complications associated with the use of an ultrasound-guided hook-wire (UGHW) LN localization method for non-palpable superficial inguinal LN (SILN) in dogs. Dogs that presented for excision of non-palpable SILN, performed with the aid of an UGHW placement, were enrolled. Information including signalment, SILN width, UGHW placement and surgical procedure time, hook-wire position, successful excision and intra-and post-operative complications were reviewed. Seventeen dogs were enrolled. Median LN width was 3 mm (range 2–11). Median time of preoperative UGHW placement and surgical LN excision was 8 min and 15 min, respectively. Successful SILN excision was achieved in all cases. Two minor intra-operative (hook migration and wire fragmentation) and one minor post-operative complications (seroma) were observed. No major intraoperative or post-operative complications occurred. The UGHW LN localization method is safe and effective and may allow a high rate of successful SILN excisions in dogs. This method has the potential to facilitate LN excision for other superficial LN locations

    The CMS Micro-strip Gas Chamber Project: Development of a high resolution tracking detector for harsh radiation environments

    Get PDF
    Thirty-two large area Micro-Strip Gas Chambers were tested in a high intensity, 350~MeV pion beam at PSI to prove that we had reached a Milestone for the Compact Muon Solenoid (CMS) experiment. The particle rate was approximately 6 kHz/mm2, distributed over the whole active area of the detectors, and this rate was maintained for a total integrated time of 493 hours. All of the chambers were operated with signal-to-noise values at or above that corresponding to 98 % hit detection efficiency at CMS; the average S/N was 31. No indications of any gain instabilities or ageing effects were observed. In the official 3-week Milestone period, three strips from a total of 16384 were damaged, a result which is twenty times lower than the minimal requirement for CMS. The spark rate of the detectors was very low and decreased with time to an average of one spark per chamber per day. The cathode voltages of 24 of the chambers were increased over a one week period to investigate the behaviour of the detectors at higher gains; the maximum S/N value was 2.4 times that at the normal working point. No significant increase in spark rate or strip loss rate was detected and the chambers operated stably. The detector efficiencies and imaging capabilities were also investigated. The MSGC design features and the assembly and test methodologies that enabled us to achieve these results are reported

    prevalence of igm and igg antibodies to west nile virus among blood donors in an affected area of north eastern italy summer 2009

    Get PDF
    Following reports of West Nile neuroinvasive disease in the north-eastern area of Italy in 2009, all blood donations dating from the period between 1 August and 31 October 2009 in the Rovigo province of the Veneto region were routinely checked to exclude those with a positive nucleic acid test for West Nile virus (WNV). Only one of 5,726 blood donations was positive (17.5 per 100,000 donations; 95% confidence interval (CI): 0.4-97.3). In addition, a selection of 2,507 blood donations collected during the period from 20 July to 15 November 2009 were screened by ELISA for IgG and IgM antibodies against WNV. A positive result was received for 94 of them. The positive sera were further evaluated using immunofluorescence and plaque reduction neutralisation test (PRNT), in which only 17 sera were confirmed positive. This corresponds to a prevalence of 6.8 per 1,000 sera (95% CI: 4.0-10.9). In a case-control study that matched each of the 17 PRNT-positive sera with four negative sera with the same date of donation and same donation centre, we did not find a significant association with age and sex of the donor; donors who worked mainly outdoors were significantly more at risk to have a positive PRNT for WNV

    Neutralising reactivity against SARS-CoV-2 delta and omicron variants by vaccination and infection history.

    Get PDF
    BACKGROUND: The continuous emergence of SARS-CoV-2 variants of concern (VOC) with immune escape properties, such as Delta (B.1.617.2) and Omicron (B.1.1.529), questions the extent of the antibody-mediated protection against the virus. Here we investigated the long-term antibody persistence in previously infected subjects and the extent of the antibody-mediated protection against B.1, B.1.617.2 and BA.1 variants in unvaccinated subjects previously infected, vaccinated naĂŻve and vaccinated previously infected subjects. METHODS: Blood samples collected 15 months post-infection from unvaccinated (n=35) and vaccinated (n=41) previously infected subjects (Vo' cohort) were tested for the presence of antibodies against the SARS-CoV-2 spike (S) and nucleocapsid (N) antigens using the Abbott, DiaSorin, and Roche immunoassays. The serum neutralising reactivity was assessed against B.1, B.1.617.2 (Delta), and BA.1 (Omicron) SARS-CoV-2 strains through micro-neutralisation. The antibody titres were compared to those from previous timepoints, performed at 2- and 9-months post-infection on the same individuals. Two groups of naĂŻve subjects were used as controls, one from the same cohort (unvaccinated n=29 and vaccinated n=20) and a group of vaccinated naĂŻve healthcare workers (n=61). RESULTS: We report on the results of the third serosurvey run in the Vo' cohort. With respect to the 9-month time point, antibodies against the S antigen significantly decreased (P=0.0063) among unvaccinated subjects and increased (P<0.0001) in vaccinated individuals, whereas those against the N antigen decreased in the whole cohort. When compared with control groups (naĂŻve Vo' inhabitants and naĂŻve healthcare workers), vaccinated subjects that were previously infected had higher antibody levels (P<0.0001) than vaccinated naĂŻve subjects. Two doses of vaccine elicited stronger anti-S antibody response than natural infection (P<0.0001). Finally, the neutralising reactivity of sera against B.1.617.2 and BA.1 was 4-fold and 16-fold lower than the reactivity observed against the original B.1 strain. CONCLUSIONS: These results confirm that vaccination induces strong antibody response in most individuals, and even stronger in previously infected subjects. Neutralising reactivity elicited by natural infection followed by vaccination is increasingly weakened by the recent emergence of VOCs. While immunity is not completely compromised, a change in vaccine development may be required going forward, to generate cross-protective pan-coronavirus immunity in the global population

    Hunt for new phenomena using large jet multiplicities and missing transverse momentum with ATLAS in 4.7 fb−1 of s√=7TeV proton-proton collisions

    Get PDF
    Results are presented of a search for new particles decaying to large numbers of jets in association with missing transverse momentum, using 4.7 fb−1 of pp collision data at s√=7TeV collected by the ATLAS experiment at the Large Hadron Collider in 2011. The event selection requires missing transverse momentum, no isolated electrons or muons, and from ≥6 to ≥9 jets. No evidence is found for physics beyond the Standard Model. The results are interpreted in the context of a MSUGRA/CMSSM supersymmetric model, where, for large universal scalar mass m 0, gluino masses smaller than 840 GeV are excluded at the 95% confidence level, extending previously published limits. Within a simplified model containing only a gluino octet and a neutralino, gluino masses smaller than 870 GeV are similarly excluded for neutralino masses below 100 GeV

    Single hadron response measurement and calorimeter jet energy scale uncertainty with the ATLAS detector at the LHC

    Get PDF
    The uncertainty on the calorimeter energy response to jets of particles is derived for the ATLAS experiment at the Large Hadron Collider (LHC). First, the calorimeter response to single isolated charged hadrons is measured and compared to the Monte Carlo simulation using proton-proton collisions at centre-of-mass energies of sqrt(s) = 900 GeV and 7 TeV collected during 2009 and 2010. Then, using the decay of K_s and Lambda particles, the calorimeter response to specific types of particles (positively and negatively charged pions, protons, and anti-protons) is measured and compared to the Monte Carlo predictions. Finally, the jet energy scale uncertainty is determined by propagating the response uncertainty for single charged and neutral particles to jets. The response uncertainty is 2-5% for central isolated hadrons and 1-3% for the final calorimeter jet energy scale.Comment: 24 pages plus author list (36 pages total), 23 figures, 1 table, submitted to European Physical Journal

    Measurement of the cross-section and charge asymmetry of WW bosons produced in proton-proton collisions at s=8\sqrt{s}=8 TeV with the ATLAS detector

    Get PDF
    This paper presents measurements of the W+→μ+νW^+ \rightarrow \mu^+\nu and W−→μ−νW^- \rightarrow \mu^-\nu cross-sections and the associated charge asymmetry as a function of the absolute pseudorapidity of the decay muon. The data were collected in proton--proton collisions at a centre-of-mass energy of 8 TeV with the ATLAS experiment at the LHC and correspond to a total integrated luminosity of 20.2~\mbox{fb^{-1}}. The precision of the cross-section measurements varies between 0.8% to 1.5% as a function of the pseudorapidity, excluding the 1.9% uncertainty on the integrated luminosity. The charge asymmetry is measured with an uncertainty between 0.002 and 0.003. The results are compared with predictions based on next-to-next-to-leading-order calculations with various parton distribution functions and have the sensitivity to discriminate between them.Comment: 38 pages in total, author list starting page 22, 5 figures, 4 tables, submitted to EPJC. All figures including auxiliary figures are available at https://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/STDM-2017-13

    Measurements of Higgs boson production and couplings in diboson final states with the ATLAS detector at the LHC

    Get PDF
    Measurements are presented of production properties and couplings of the recently discovered Higgs boson using the decays into boson pairs, H →γ γ, H → Z Z∗ →4l and H →W W∗ →lνlν. The results are based on the complete pp collision data sample recorded by the ATLAS experiment at the CERN Large Hadron Collider at centre-of-mass energies of √s = 7 TeV and √s = 8 TeV, corresponding to an integrated luminosity of about 25 fb−1. Evidence for Higgs boson production through vector-boson fusion is reported. Results of combined fits probing Higgs boson couplings to fermions and bosons, as well as anomalous contributions to loop-induced production and decay modes, are presented. All measurements are consistent with expectations for the Standard Model Higgs boson

    Standalone vertex nding in the ATLAS muon spectrometer

    Get PDF
    A dedicated reconstruction algorithm to find decay vertices in the ATLAS muon spectrometer is presented. The algorithm searches the region just upstream of or inside the muon spectrometer volume for multi-particle vertices that originate from the decay of particles with long decay paths. The performance of the algorithm is evaluated using both a sample of simulated Higgs boson events, in which the Higgs boson decays to long-lived neutral particles that in turn decay to bbar b final states, and pp collision data at √s = 7 TeV collected with the ATLAS detector at the LHC during 2011
    • …
    corecore