1,842 research outputs found

    Strain-induced kinetics of intergrain defects as the mechanism of slow dynamics in the nonlinear resonant response of humid sandstone bars

    Full text link
    A closed-form description is proposed to explain nonlinear and slow dynamics effects exhibited by sandstone bars in longitudinal resonance experiments. Along with the fast subsystem of longitudinal nonlinear displacements we examine the strain-dependent slow subsystem of broken intergrain and interlamina cohesive bonds. We show that even the simplest but phenomenologically correct modelling of their mutual feedback elucidates the main experimental findings typical for forced longitudinal oscillations of sandstone bars, namely, (i) hysteretic behavior of a resonance curve on both its up- and down-slopes, (ii) linear softening of resonant frequency with increase of driving level, and (iii) gradual recovery (increase) of resonant frequency at low dynamical strains after the sample was conditioned by high strains. In order to reproduce the highly nonlinear elastic features of sandstone grained structure a realistic non-perturbative form of strain potential energy was adopted. In our theory slow dynamics associated with the experimentally observed memory of peak strain history is attributed to strain-induced kinetic changes in concentration of ruptured inter-grain and inter-lamina cohesive bonds causing a net hysteretic effect on the elastic Young's modulus. Finally, we explain how enhancement of hysteretic phenomena originates from an increase in equilibrium concentration of ruptured cohesive bonds that are due to water saturation.Comment: 5 pages, 3 figure

    Patient Choice for Older People in English NHS Primary Care: Theory and Practice

    Get PDF
    In the English National Health Service (NHS), patients are now expected to choose the time and place of treatment and even choose the actual treatment. However, the theory on which patient choice is based and the implementation of patient choice are controversial. There is evidence to indicate that attitudes and abilities to make choices are relatively sophisticated and not as straightforward as policy developments suggest. In addition, and surprisingly, there is little research on whethermaking individual choices about care is regarded as a priority by the largest NHS patient group and the single largest group for most GPs—older people.This conceptual paper examines the theory of patient choice concerning accessing and engaging with healthcare provision and reviews existing evidence on older people and patient choice in primary care

    Remote Non-invasive Stereoscopic Imaging of Blood Vessels: First In-vivo Results of a New Multispectral Contrast Enhancement Technology

    Get PDF
    We describe a contactless optical technique selectively enhancing superficial blood vessels below variously pigmented intact human skin by combining images in different spectral bands. Two CMOS-cameras, with apochromatic lenses and dual-band LED-arrays, simultaneously streamed Left (L) and Right (R) image data to a dual-processor PC. Both cameras captured color images within the visible range (VIS, 400–780 nm) and grey-scale images within the near infrared range (NIR, 910–920 nm) by sequentially switching between LED-array emission bands. Image-size-settings of 1280 × 1024 for VIS & 640 × 512 for NIR produced 12 cycles/s (1 cycle = 1 VIS L&R-pair + 1 NIR L&R-pair). Decreasing image-size-settings (640 × 512 for VIS and 320 × 256 for NIR) increased camera-speed to 25 cycles/s. Contrasts from below the tissue surface were algorithmically distinguished from surface shadows, reflections, etc. Thus blood vessels were selectively enhanced and back-projected into the stereoscopic VIS-color-image using either a 3D-display or conventional shutter glasses. As a first usability reconnaissance we applied this custom-built mobile stereoscopic camera for several clinical settings: • blood withdrawal; • vein inspection in dark skin; • vein detection through iodide; • varicose vein and nevi pigmentosum inspection. Our technique improves blood vessel visualization compared to the naked eye, and supports depth perception

    ОБМЕН СООБЩЕНИЯМИ В МИКС-СЕТЯХ

    Get PDF
    Рассмотрена идея Д.Чаума организации анонимной микс-сети с пересылкой сообщений через каскад миксов (передаточных узлов) и последовательным шифрованием всех промежуточных результатов. Описаны задачи, решаемые миксами в ходе обеспечения анонимности связи, обговариваются проблемы ее безопасности

    On the Hybrid Extension of CTL and CTL+

    Full text link
    The paper studies the expressivity, relative succinctness and complexity of satisfiability for hybrid extensions of the branching-time logics CTL and CTL+ by variables. Previous complexity results show that only fragments with one variable do have elementary complexity. It is shown that H1CTL+ and H1CTL, the hybrid extensions with one variable of CTL+ and CTL, respectively, are expressively equivalent but H1CTL+ is exponentially more succinct than H1CTL. On the other hand, HCTL+, the hybrid extension of CTL with arbitrarily many variables does not capture CTL*, as it even cannot express the simple CTL* property EGFp. The satisfiability problem for H1CTL+ is complete for triply exponential time, this remains true for quite weak fragments and quite strong extensions of the logic

    Large-scale extrusion processing and characterization of hybrid nylon-6/SiO2 nanocomposites

    Get PDF
    Solution impregnations, pulltrusion and film stacking are widely used methods to prepare thermoplastic composite materials. Extruders are used to melt the polymer and to incorporate fibers into the polymer in order to modify physical properties. In this article, the compounding of colloidal silica nanoparticles filled polyamide-6 (PA-6) is achieved using a twin-screw extruder, which has a significant market share due to its low cost and easy maintenance. The experiments were performed at 250 rpm and the bulk throughput was 6 kg h(-1) with a pump pressure of 30 bars. The composites were characterized with nuclear magnetic resonance (NMR), wide angle X-ray diffraction (WAXD), differential scanning calorimetry (DSC) and transmission electron microscopy (TEM). As determined by WAXD, the PA-6 showed higher amounts of gamma-phase when compared to other synthesis methods such as in situ polymerization. TEM pictures showed that the silica particles aggregated nevertheless, upon addition of 14% (w/w) silica the E-modulus increased from 2.7 to 3.9 GPa indicating that an effective mechanical coupling with the polymer was achieved. The behavior, illustrated with dynamic mechanical analysis (DMA) curves, indicated that in general when a filled system is compared to unfilled material, the values of the moduli (E' and E") increased and tan 6 decreased. Determination of molecular mass distribution of the samples by means of size exclusion chromatography (SEC) coupled to a refractive index (RI), viscosity (DV) and light scattering (LS) detector revealed that the addition of silica did not decrease the average molecular weight of the polymer matrix, which is of importance for composite applications. Copyright (C) 2004 John Wiley Sons, Ltd.</p

    Laboratory testing in patients treated with direct oral anticoagulants: a practical guide for clinicians

    Get PDF
    Click to hear Dr Baglin's perspective on the role of the laboratory in treatment with new oral anticoagulants SUMMARY: One of the key benefits of the direct oral anticoagulants (DOACs) is that they do not require routine laboratory monitoring. Nevertheless, assessment of DOAC exposure and anticoagulant effects may become useful in various clinical scenarios. The five approved DOACs (apixaban, betrixaban, dabigatran etexilate, edoxaban and rivaroxaban) have different characteristics impacting assay selection and the interpretation of results. This article provides an updated overview on (i) which test to use (and their advantages and limitations), (ii) when to assay DOAC levels, (iii) how to interpret the results relating to bleeding risk, emergency situations and perioperative management, and (iv) what is the impact of DOACs on routine and specialized coagulation assays. Assays for anti-Xa or anti-IIa activity are the preferred methods when quantitative information is useful, although the situations in which to test for DOAC levels are still debated. Different reagent sensitivities and variabilities in laboratory calibrations impact assay results. International calibration standards for all specific tests for each DOAC are needed to reduce the inter-laboratory variability and allow inter-study comparisons. The impact of the DOACs on hemostasis testing may cause false-positive or false-negative results; however, these can be minimized by using specific assays and collecting blood samples at trough concentrations. Finally, prospective clinical trials are needed to validate the safety and efficacy of proposed laboratory thresholds in relation to clinical decisions. We offer recommendations on the tests to use for measuring DOACs and practical guidance on laboratory testing to help patient management and avoid diagnostic errors. ispartof: Journal of Thrombosis and Haemostasis vol:16 issue:2 pages:209-219 ispartof: location:England status: publishe

    Extreme interatrial conduction delay and regularization of atrial arrhythmias in a subgroup of patients with hypertrophic cardiomyopathy

    Get PDF
    Background: Hypertrophic cardiomyopathy (HCM) patients may develop interatrial activation delay, indicated by a complete separation of the right and left atrial activation on the ECG. This study aimed to determine the prevalence of interatrial activation delay and the relation to atrial tachycardia (AT) cycle length (CL) in HCM patients. Methods: 159 HCM patients were included (mean age 52±14y). In group I (n=15, 9%) patients had atrial arrhythmias and progressive ATCL. In group II (n=22, 14%) patients had a stable ATCL. In group III (n=122, 77%) HCM patients without AT were included. P wave morphology and change in P wave duration (δP and Pmax) and changes in ATCL (δATCL) were analyzed. Mean follow-up was 8.7±4.7years. Results: In group I 33% (n=5) had separated P waves. In group II no P wave separation was identified (OR 1.50 [1.05-2.15], p=0.007). In group I patients were older compared to group III (62.6±15.1 vs. 50.2±14.0y, p=0.002) and had longer follow-up (13.4±2.2 vs. 7.8±4.6y, p<0.001). In group III Pmax and δP were significantly lower (105.1±22.0ms and 8.9±13.2ms, both p<0.0001). Group I patients had an increased LA size compared to group II (61.1±11.6 vs. 53.7±7.5mm, p=0.028) and higher E/A and E/E prime ratios (p=0.007; p=0.037, respectively). In group I 93.3% of the identified mutations were typical Dutch founder mutations of the MYBPC3 gene. Conclusion: In HCM patients a unique combination of separated P waves and regularization of ATs is associated with larger atria, higher LA pressures and myosin binding protein mutations
    corecore