    Transitional circulation and hemodynamic monitoring in newborn infants

    Get PDF
    Transitional circulation is normally transient after birth but can vary markedly between infants. It is actually in a state of transition between fetal (in utero) and neonatal (postnatal) circulation. In the absence of definitive clinical trials, information from applied physiological studies can be used to facilitate clinical decision making in the presence of hemodynamic compromise. This review summarizes the peculiar physiological features of the circulation as it transitions from one phenotype into another in term and preterm infants. The common causes of hemodynamic compromise during transition, intact umbilical cord resuscitation, and advanced hemodynamic monitoring are discussed.Developmen

    The development and validation of a cerebral ultrasound scoring system for infants with hypoxic-ischaemic encephalopathy

    Get PDF
    BACKGROUND: Hypoxic-ischaemic encephalopathy (HIE) is an important cause of morbidity and mortality in neonates. When the gold standard MRI is not feasible, cerebral ultrasound (CUS) might offer an alternative. In this study, the association between a novel CUS scoring system and neurodevelopmental outcome in neonates with HIE was assessed. METHODS: (Near-)term infants with HIE and therapeutic hypothermia, a CUS on day 1 and day 3-7 after birth and available outcome data were retrospectively included in cohort I. CUS findings on day 1 and day 3-7 were related to adverse outcome in univariate and the CUS of day 3-7 also in multivariable logistic regression analyses. The resistance index, the sum of deep grey matter and of white matter involvement were included in multivariable logistic regression analyses. A comparable cohort from another hospital was used for validation (cohort II). RESULTS: Eighty-three infants were included in cohort I and 35 in cohort II. The final CUS scoring system contained the sum of white matter (OR = 2.6, 95% CI 1.5-4.7) and deep grey matter involvement (OR = 2.7, 95% CI 1.7-4.4). The CUS scoring system performed well in cohort I (AUC = 0.90) and II (AUC = 0.89). CONCLUSION: This validated CUS scoring system is associated with neurodevelopmental outcome in neonates with HIE

    Preterm white matter injury : ultrasound diagnosis and classification

    Get PDF
    White matter injury (WMI) is the most frequent form of preterm brain injury. Cranial ultrasound (CUS) remains the preferred modality for initial and sequential neuroimaging in preterm infants, and is reliable for the diagnosis of cystic periventricular leukomalacia. Although magnetic resonance imaging is superior to CUS in detecting the diffuse and more subtle forms of WMI that prevail in very premature infants surviving nowadays, recent improvement in the quality of neonatal CUS imaging has broadened the spectrum of preterm white matter abnormalities that can be detected with this technique. We propose a structured CUS assessment of WMI of prematurity that seeks to account for both cystic and non-cystic changes, as well as signs of white matter loss and impaired brain growth and maturation, at or near term equivalent age. This novel assessment system aims to improve disease description in both routine clinical practice and clinical research. Whether this systematic assessment will improve prediction of outcome in preterm infants with WMI still needs to be evaluated in prospective studies

    State-of-the-art neonatal cerebral ultrasound: technique and reporting

    Get PDF
    In the past three decades, cerebral ultrasound (CUS) has become a trusted technique to study the neonatal brain. It is a relatively cheap, non-invasive, bedside neuroimaging method available in nearly every hospital. Traditionally, CUS was used to detect major abnormalities, such as intraventricular hemorrhage (IVH), periventricular hemorrhagic infarction, post-hemorrhagic ventricular dilatation, and (cystic) periventricular leukomalacia (cPVL). The use of different acoustic windows, such as the mastoid and posterior fontanel, and ongoing technological developments, allows for recognizing other lesion patterns (e.g., cerebellar hemorrhage, perforator stroke, developmental venous anomaly). The CUS technique is still being improved with the use of higher transducer frequencies (7.5-18\u2009MHz), 3D applications, advances in vascular imaging (e.g. ultrafast plane wave imaging), and improved B-mode image processing. Nevertheless, the helpfulness of CUS still highly depends on observer skills, knowledge, and experience. In this special article, we discuss how to perform a dedicated state-of-the-art neonatal CUS, and we provide suggestions for structured reporting and quality assessment

    Newborn resuscitation and support of transition of infants at birth European Resuscitation Council Guidelines 2021

    Get PDF
    The European Resuscitation Council has produced these newborn life support guidelines, which are based on the International Liaison Committee on Resuscitation (ILCOR) 2020 Consensus on Science and Treatment Recommendations (CoSTR) for Neonatal Life Support. The guidelines cover the management of the term and preterm infant. The topics covered include an algorithm to aid a logical approach to resuscitation of the newborn, factors before delivery, training and education, thermal control, management of the umbilical cord after birth, initial assessment and categorisation of the newborn infant, airway and breathing and circulation support, communication with parents, considerations when withholding and discontinuing support.Developmen

    Higher CPAP levels improve functional residual capacity at birth in preterm rabbits

    Get PDF
    BACKGROUND: Preterm infants are commonly supported with 4-8 cm H2O continuous positive airway pressures (CPAP), although higher CPAP levels may improve functional residual capacity (FRC).METHODS: Preterm rabbits delivered at 29/32 days (similar to 26-28 weeks human) gestation received 0, 5, 8, 12, 15 cm H2O of CPAP or variable CPAP of 15 to 5 or 15 to 8 cm H2O (decreasing similar to 2 cm H2O/min) for up to 10 min after birth.RESULTS: FRC was lower in the 0 (6.8 (1.0-11.2) mL/kg) and 5 (10.1 (1.1-16.8) mL/kg) compared to the 15 (18.8 (10.9-22.4) mL/kg) cm H2O groups (p = 0.003). Fewer kittens achieved FRC > 15 mL/kg in the 0 (20%), compared to 8 (36%), 12 (60%) and 15 (73%) cm H2O groups (p = 0.008). While breathing rates were not different (p = 0.096), apnoea tended to occur more often with CPAP < 8 cm H2O (p = 0.185). CPAP belly and lung bulging rates were similar whereas pneumothoraces were rare. Lowering CPAP from 15 to 5, but not 15 to 8 cm H2O, decreased FRC and breathing rates.CONCLUSION: In all, 15 cm H2O of CPAP improved lung aeration and reduced apnoea, but did not increase the risk of lung over-expansion, pneumothorax or CPAP belly immediately after birth. FRC and breathing rates were maintained when CPAP was decreased to 8 cm H2O.Developmen

    Increasing Respiratory Effort With 100% Oxygen During Resuscitation of Preterm Rabbits at Birth

    Get PDF
    Background: Spontaneous breathing is essential for successful non-invasive respiratory support delivered by a facemask at birth. As hypoxia is a potent inhibitor of spontaneous breathing, initiating respiratory support with a high fraction of inspired O2 may reduce the risk of hypoxia and increase respiratory effort at birth. Methods: Preterm rabbit kittens (29 days gestation, term ~32 days) were delivered and randomized to receive continuous positive airway pressure with either 21% (n = 12) or 100% O2 (n = 8) via a facemask. If apnea occurred, intermittent positive pressure ventilation (iPPV) was applied with either 21% or 100% O2 in kittens who started in 21% O2, and remained at 100% O2 for kittens who started the experiment in 100% O2. Respiratory rate (breaths per minute, bpm) and variability in inter-breath interval (%) were measured from esophageal pressure recordings and functional residual capacity (FRC) was measured from synchrotron phase-contrast X-ray images. Results: Initially, kittens receiving 21% O2 had a significantly lower respiratory rate and higher variability in inter-breath interval, indicating a less stable breathing pattern than kittens starting in 100% O2 [median (IQR) respiratory rate: 16 (4–28) vs. 38 (29–46) bpm, p = 0.001; variability in inter-breath interval: 33.3% (17.2–50.1%) vs. 27.5% (18.6–36.3%), p = 0.009]. Apnea that required iPPV, was more frequently observed in kittens in whom resuscitation was started with 21% compared to 100% O2 (11/12 vs. 1/8, p = 0.001). After recovering from apnea, respiratory rate was significantly lower and variability in inter-breath interval was significantly higher in kittens who received iPPV with 21% compared to 100% O2. FRC was not different between study groups at both timepoints. Conclusion: Initiating resuscitation with 100% O2 resulted in increased respiratory activity and stability, thereby reducing the risk of apnea and need for iPPV after birth. Further studies in human preterm infants are mandatory to confirm the benefit of this approach in terms of oxygenation. In addition, the ability to avoid hyperoxia after initiation of resuscitation with 100% oxygen, using a titration protocol based on oxygen saturation, needs to be clarified

    Neonatal resuscitation research: closing the gap

    No full text
    Developmen