123 research outputs found

    Impact of Chitosan-Based Foliar Application on the Phytochemical Content and the Antioxidant Activity in Hemp (Cannabis sativa L.) Inflorescences

    Get PDF
    In the present study, the phytochemical content and the antioxidant activity in the inflorescences of the monoecious hemp cultivar Codimono grown in southern Italy were assessed, and their elicitation was induced by foliar spray application of 50 mg/L and 250 mg/L of chitosan (CHT) at three different molecular weights (low, CHT L; medium, CHT M; high CHT H). The analysis of the phytochemical profile confirmed that cannabinoids were the most abundant class (54.2%), followed by flavonoids (40.3%), tocopherols (2.2%), phenolic acids (1.9%), and carotenoids (1.4%). Cannabinoids were represented almost exclusively by cannabidiol, whereas cannabigerol and Δ9-tetrahydrocannabinol were detected at very low levels (the latter was below the legal limit of 0.3%). The most abundant flavonoids were orientin and vitexin, whereas tocopherols were mainly represented by α-tocopherol. The antioxidant activity was found to be positively correlated with flavonoids and tocopherols. Statistical analysis revealed that the CHT treatments significantly affected the phytochemical content and the antioxidant activity of hemp inflorescences. Notably, a significant increase in the total phenolic content (from +36% to +69%), the α-tocopherol (from +45% to +75%) and β+γ-tocopherol (from +35% to +82%) contents, and the ABTS radical scavenging activity (from +12% to +28%) was induced by all the CHT treatments. In addition, treatments with CHT 50 solutions induced an increase in the total flavonoid content (from +12% to +27%), as well as in the vitexin (from +17% to +20%) and orientin (from +20% to +30%) contents. Treatment with CHT 50 L almost always resulted in the greatest increases. Overall, our findings indicated that CHT could be used as a low-cost and environmentally safe elicitor to improve the health benefits and the economic value of hemp inflorescences, thus promoting their employment in the food, pharmaceutical, nutraceutical, and cosmetic supply chains

    Is there a relationship between joint hypermobility and gastrointestinal disorders in children?

    Get PDF
    Background. The main aim of the study was to assess the association between joint hypermobility (JH) and gastrointestinal (GI) disorders in children. Methods. All children aged 4-17 years attending the clinics of the participating Pediatric Gastroenterology Centres for functional GI disorders (FGIDs) and inflammatory bowel disease (IBD) were screened for joint laxity. JH diagnosis was inferred using the Beighton Score. JHS diagnosis was inferred based on the Brighton Criteria. Rome III Diagnostic Criteria were used to diagnose possible FGIDs. Ulcerative colitis and Crohn’s disease diagnoses were made according to the Porto Criteria. Age and sex- matched healthy children were enrolled as controls. Results. One-hundred-seventy children with GI disorders (70 with FGIDs, 50 with Crohn’s disease, and 50 with ulcerative colitis) and 100 healthy controls were enrolled in the study. JH was reported in 7/70 (10%) children with FGIDs (p=0.26 compared to controls), 4/50 (8%) children with Crohn’s disease (p=0.21 compared to controls) and 15/50 (30%) children with ulcerative colitis (p=0.09 compared to controls; p=0.01 compared to FGIDs; p=0.01 compared to Crohn’s). Conclusions. JH is more prevalent in patients suffering from ulcerative colitis compared to the healthy general population, yet the difference did not reach statistical significance. Likely, a proportion of children with ulcerative colitis and JH may show connective tissue abnormalities. However, whether JH can be considered a possible feature of pediatric GI disorders deserves further investigation

    Teaching Robust Argumentation Informed by the Nature of Science to Support Social Justice. Experiences from Two Projects in Lower Secondary Schools in Norway

    Get PDF
    Under embargo until: 2022-09-09This chapter suggests a set of design principles for science curricula that will enable students to produce evidence-based arguments expressing views related to their own interests. It is based on the assumption that the ability to construct evidence-based arguments strengthens students’ ability to promote their own views in the interest of social justice. This is of special importance for students not enculturated into such argumentation through their upbringing. To promote one’s own views in a debate means to critique others’ arguments, and especially to ensure one’s own arguments are resistent to criticism. Insight into the nature of science includes insights in how to construct sound arguments based on facts and research results. The discussion of design principles is based on an analysis of two science projects in two lower secondary schools in Norway (Grade 8). In the first project, students produced scientific claims based on evidence from their own practical experiments. In the second project, the students developed and applied a method for estimating energy use and carbon dioxide (CO2) emissions. The students used their findings to construct arguments related to local transport plans. The analysis focuses on challenges and successes in scaffolding students at different competence levels to successfully produce evidence-based arguments.acceptedVersio

    Cyclic vomiting syndrome in children: a nationwide survey of current practice on behalf of the Italian Society of Pediatric Gastroenterology, Hepatology and Nutrition (SIGENP) and Italian Society of Pediatric Neurology (SINP)

    Get PDF
    Background: Cyclic Vomiting Syndrome (CVS) is a rare functional gastrointestinal disorder, which has a considerable burden on quality of life of both children and their family. Aim of the study was to evaluate the diagnostic modalities and therapeutic approach to CVS among Italian tertiary care centers and the differences according to subspecialties, as well as to explore whether potential predictive factors associated with either a poor outcome or a response to a specific treatment. Methods: Cross-sectional multicenter web-based survey involving members of the Italian Society of Pediatric Gastroenterology, Hepatology and Nutrition (SIGENP) and Italian Society of Pediatric Neurology (SINP). Results: A total of 67 responses were received and analyzed. Most of the respondent units cared for less than 20 patients. More than half of the patients were referred after 3 to 5 episodes, and a quarter after 5 attacks. We report different diagnostic approaches among Italian clinicians, which was particularly evident when comparing gastroenterologists and neurologists. Moreover, our survey demonstrated a predilection of certain drugs during emetic phase according to specific clinic, which reflects the cultural background of physicians. Conclusion: In conclusion, our survey highlights poor consensus amongst clinicians in our country in the diagnosis and the management of children with CVS, raising the need for a national consensus guideline in order to standardize the practice

    Status and prospects of discovery of 0νββ decay with the CUORE detector

    Get PDF
    In this contribution we present the achievements of the CUORE experiment so far. It is the first tonne-scale bolometric detector and it is in stable data taking since 2018. We reached to collect about 1800 kg×yr of exposure of which more than 1ton×year have been analysed. The CUORE detector is meant to search for the neutrinoless double β decay (0νββ) of the 130Te isotope. This is a beyond Standard Model process which could establish the nature of the neutrino to be Dirac or a Majorana particle. It is an alternative mode of the two-neutrinos double β decay, a rare decay which have been precisely measured by CUORE in the 130Te. We found no evidence of the 0νββ and we set a Bayesian lower limit of 2.2×1025yr on its half-life. The expertise achieved by CUORE set a milestone for any future bolometric detector, including CUPID, which is the planned next generation experiment searching for 0νββ with scintillating bolometers

    An integrated map of structural variation in 2,504 human genomes

    Get PDF
    Structural variants are implicated in numerous diseases and make up the majority of varying nucleotides among human genomes. Here we describe an integrated set of eight structural variant classes comprising both balanced and unbalanced variants, which we constructed using short-read DNA sequencing data and statistically phased onto haplotype blocks in 26 human populations. Analysing this set, we identify numerous gene-intersecting structural variants exhibiting population stratification and describe naturally occurring homozygous gene knockouts that suggest the dispensability of a variety of human genes. We demonstrate that structural variants are enriched on haplotypes identified by genome-wide association studies and exhibit enrichment for expression quantitative trait loci. Additionally, we uncover appreciable levels of structural variant complexity at different scales, including genic loci subject to clusters of repeated rearrangement and complex structural variants with multiple breakpoints likely to have formed through individual mutational events. Our catalogue will enhance future studies into structural variant demography, functional impact and disease association. © 2015 Macmillan Publishers Limited. All rights reserved

    Twelve-crystal prototype of Li2_2MoO4_4 scintillating bolometers for CUPID and CROSS experiments

    Full text link
    An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μ\muBq/kg, level of the LMO crystals radioactive contamination by 228^{228}Th and 226^{226}Ra.Comment: Prepared for submission to JINST; 23 pages, 9 figures, and 4 table

    A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

    Get PDF
    CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100^{100}Mo. It will operate at \sim10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100^{100}Mo-enriched Li2_2MoO4_4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70--90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained outstanding energy resolutions at the 356 keV line from a 133^{133}Ba source with one light detector achieving 0.71(5) keV FWHM, which is -- to our knowledge -- the best ever obtained when compared to γ\gamma detectors of any technology in this energy range.Comment: Prepared for submission to JINST; 16 pages, 7 figures, and 1 tabl
    corecore