214 research outputs found
86-km optical link with a resolution of 2.10-18 for RF frequency transfer
RF frequency transfer over an urban 86 km fibre has been demonstrated with a
resolution of 2.10-18 at one day measuring time using an optical compensator.
This result is obtained with a reference carrier frequency of 1 GHz, and a
rapid scrambling of the polarisation state of the input light in order to
reduce the sensitivity to the polarisation mode dispersion in the fibre. The
limitation due to the fibre chromatic dispersion associated with the laser
frequency fluctuations is highlighted and analyzed. A preliminary test of an
extended compensated link over 186 km using optical amplifiers gives a
resolution below 10-17 at 1 day
The lady vanishes: what's missing from the stem cell debate
Most opponents of somatic cell nuclear transfer and embryonic stem cell technologies base their arguments on the twin assertions that the embryo is either a human being or a potential human being, and that it is wrong to destroy a human being or potential human being in order to produce stem cell lines. Proponents’ justifications of stem cell research are more varied, but not enough to escape the charge of obsession with the status of the embryo. What unites the two warring sides in ‘the stem cell wars’ is that women are equally invisible to both: ‘the lady vanishes’. Yet the only legitimate property in the body is that which women possess in their reproductive tissue and the products of their reproductive labour. By drawing on the accepted characterisation in law of property as a bundle of rights, and on a Hegelian model of contract as mutual recognition, we can lessen the impact of the tendency to regard women and their eggs as merely receptacles and women’s reproductive labour as unimportant
Higher harmonic anisotropic flow measurements of charged particles in Pb-Pb collisions at 2.76 TeV
We report on the first measurement of the triangular , quadrangular
, and pentagonal charged particle flow in Pb-Pb collisions at 2.76
TeV measured with the ALICE detector at the CERN Large Hadron Collider. We show
that the triangular flow can be described in terms of the initial spatial
anisotropy and its fluctuations, which provides strong constraints on its
origin. In the most central events, where the elliptic flow and
have similar magnitude, a double peaked structure in the two-particle azimuthal
correlations is observed, which is often interpreted as a Mach cone response to
fast partons. We show that this structure can be naturally explained from the
measured anisotropic flow Fourier coefficients.Comment: 10 pages, 4 figures, published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/387
Planck Intermediate Results II: Comparison of Sunyaev–Zeldovich measurements from Planck and from the Arcminute Microkelvin Imager for 11 galaxy clusters
A comparison is presented of Sunyaev–Zeldovich measurements for 11 galaxy clusters as obtained by Planck and by the ground-based interferom- eter, the Arcminute Microkelvin Imager. Assuming a universal spherically-symmetric Generalised Navarro, Frenk & White (GNFW) model for the cluster gas pressure profile, we jointly constrain the integrated Compton-Y parameter (Y500) and the scale radius (θ500) of each cluster. Our resulting constraints in the Y500 − θ500 2D parameter space derived from the two instruments overlap significantly for eight of the clusters, although, overall, there is a tendency for AMI to find the Sunyaev–Zeldovich signal to be smaller in angular size and fainter than Planck. Significant discrepancies exist for the three remaining clusters in the sample, namely A1413, A1914, and the newly-discovered Planck cluster PLCKESZ G139.59+24.18. The robustness of the analysis of both the Planck and AMI data is demonstrated through the use of detailed simulations, which also discount confusion from residual point (radio) sources and from diffuse astrophysical foregrounds as possible explanations for the discrepancies found. For a subset of our cluster sample, we have investigated the dependence of our results on the assumed pressure profile by repeating the analysis adopting the best-fitting GNFW profile shape which best matches X-ray observations. Adopting the best-fitting profile shape from the X-ray data does not, in general, resolve the discrepancies found in this subset of five clusters. Though based on a small sample, our results suggest that the adopted GNFW model may not be sufficiently flexible to describe clusters universally
The ALICE Transition Radiation Detector: Construction, operation, and performance
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection. (c) 2017 CERN for the benefit of the Authors. Published by Elsevier B.V
Planck intermediate results I : Further validation of new Planck clusters with XMM-Newton
Peer reviewe
- …