127 research outputs found

    Investigation of the stability of commercial neutron probes

    Get PDF
    At the Paul Scherrer Institute's Calibration Laboratory, neutron reference fields are provided for the calibration of ambient and personal dose equivalent (rate) metres and passive dosemeters. To ensure traceability to the standards of the Physikalisch-Technische Bundesanstalt (PTB) in Germany, the neutron fields are characterised by means of a PTB-calibrated Berthold LB6411 neutron probe which is used as a secondary standard. The LB6411 detector suffers from an unstable, increasing dose rate reading in the order of up to +5 % (according to the manufacturers, this is due to a charging effect in the 3He proportional counter). In a calibration, this instability is usually corrected for based on the reading obtained with a test source. In this work, the instability was investigated by means of measurements under irradiation with ambient dose equivalent rates up to 24 mSv h-1 for up to 20 h and compared with the behaviour of an LB6419 and a Thermo Wendi-2 probe. The reading of the instruments was found to reach a plateau, e.g. it becomes stable after ∼90 min during irradiation with 10 mSv h-1 neutrons. The plateau is reached faster for higher dose rates. This supports the interpretation as a charging effect in the proportional counter. The effect could also be duplicated in an irradiation with photons from a 137Cs source. The decay time of the accumulated charge was found to be very long, i.e. the instrument showed a stable reproducible reading for up to 6 h after the plateau was reached. From these observations, a conditioning procedure was derived which ensures a stable operation of the instrument after an irradiation of the instrument preceding its use in the reference measurement

    USING GASEOUS EMISSIONS OF A PROTON ACCELERATOR FACILITY AS TRACER FOR SMALL-SCALE ATMOSPHERIC DISPERSION

    Get PDF
    The gaseous effluents of the proton accelerator facility located in the Western part of the Paul Scherrer Institute, Aargau, Switzerland, contain a mixture of positron emitters (50 % 15O, 20 % 13N and 30 % 11C). For the experimental verification of a future upgrade of the dispersion model in the complex topography of the Aare valley, a measuring campaign using three continuous gamma-spectrometric measuring stations was launched in 2011. The concept of a modified man-made-gross-count (MMGC) ratio yields a clear signal associated with the positron emitters while minimising the influence of radon progeny rain-out events. A dependence of the measured MMGC ratios on the emitted activity and wind direction could be demonstrated using frequency distributions of the modified MMGC ratio measured in 2012 and 2013. A significant fraction of high MMGC-ratio values was found associated with dispersion directions (based on measurements of the wind direction in 70 m above ground) not towards or even against the direction between stack and measuring statio

    Reference instruments based on spectrometric measurement with Lucas Cells

    Get PDF
    The Bundesamt für Strahlenschutz (Berlin, Germany) and the Paul Scherrer Institute (Villigen, Switzerland) both operate accredited calibration laboratories for radon gas activity concentration. Both the institutions use Lucas Cells as detector in their reference instrumentation due to the low dependence of this detector type on variations in environmental conditions. As a further measure to improve the quality of the reference activity concentration, a spectrometric method of data evaluation has been applied. The electric pulses from the photomultiplier tube coupled to the Lucas Cells are subjected to a pulse height analysis. The stored pulse height spectra are analysed retrospectively to compensate for fluctuations in the electric parameters of the instrumentation during a measurement. The reference instrumentation of both the laboratories is described with the respective spectrum evaluation procedures. The methods of obtaining traceability to the primary calibration laboratories of Germany and Switzerland and data of performance tests are presente

    Calibration of the Politrack® system based on CR39 solid-state nuclear track detectors for passive indoor radon concentration measurements

    Get PDF
    Swiss national requirements for measuring radon gas exposures demand a lower detection limit of 50 kBq h m−3, representing the Swiss concentration average of 70 Bq m−3 over a 1-month period. A solid-state nuclear track detector (SSNTD) system (Politrack, Mi.am s.r.l., Italy) has been acquired to fulfil these requirements. This work was aimed at the calibration of the Politrack system with traceability to international standards and the development of a procedure to check the stability of the system. A total of 275 SSNTDs was exposed to 11 different radon exposures in the radon chamber of the Secondary Calibration Laboratory at the Paul Scherrer Institute, Switzerland. The exposures ranged from 50 to 15000 kBq h m−3. For each exposure of 20 detectors, 5 SSNTDs were used to monitor possible background exposures during transport and storage. The response curve and the calibration factor of the whole system were determined using a Monte Carlo fitting procedure. A device to produce CR39 samples with a reference number of tracks using a 241Am source was developed for checking the long-term stability of the Politrack system. The characteristic limits for the detection of a possible system drift were determined following ISO Standard 1192

    Analytical expressions for the conductance noise measured with four circular contacts placed in a square array

    Get PDF
    In the ideal case, noise measurements with four contacts minimize the contribution of the contact interface. There is a need to characterize conductance noise and noise correction factors for the different geometries provided with four contacts, as already is the case for resistivity measurements with van der Pauw structures. Here, we calculate the noise correction factors for two geometries with a pair of sensors and a pair of current driver electrodes placed in a square array. The first geometry investigated is a very large film compared to the distance L between four circular electrodes, which are placed in a square array far away from the borders of the film. The second is a square-shaped conductive film with side length L and provided with four quarter-circle corner contacts with radius l. The effect of the conductance noise in the film can be observed between current free sensors in a four-point measurement or between current carrying drivers in a two-point measurement. Our analytical expressions are based on approximations to solve the integrals (J·)2dA and |J|4dA for the voltage noise measured across a pair of sensors, SVQ, and across the drivers, SVD, respectively. The first and second integrands represent the squared dot product of the current density and adjoint current density and the modulus of the current density to the fourth power, respectively. The current density J in the samples is due to the current I passing through the driver contacts. The calculated expressions are applicable to samples with thickness tl0.1L. Hence, the disturbances in the neighborhood of the sensors on J and of the drivers on are ignored. Noise correction factors for two- and four-point measurements are calculated for sensors on an equipotential (transversal noise) with the driver contacts on the diagonal of a square and for sensors next to each other on one side of the square with the drivers next to each other on the other side of the square (longitudinal noise). In all cases the noise between the sensors is smaller and less sensitive to the contact size 2l/L than the noise between the drivers. The ratio SVQ/SVD becomes smaller with smaller contact radius l. Smaller sensors give a better suppression of interface noise at the contacts. But overly low 2l/L values result in overly high resistance between the sensors and too strong a contribution of thermal noise at the sensors. Therefore, equations are derived to calculate the current level needed to observe 1/f conductance fluctuations on top of the thermal noise. The results from the calculated analytical expressions show good agreement with experimental results obtained from the noise in carbon sheet resistance and numerical results. Transversal noise measurements on a square sample with corner contacts are recommended to characterize the 1/f noise of the layer. This is due to the increased current densities in the sample compared to the open structure, which result in easier detection of the 1/f on top of the thermal noise. ©2007 American Institute of Physic

    Calibration of the Politrack® system based on CR39 solid-state nuclear track detectors for passive indoor radon concentration measurements.

    Get PDF
    Swiss national requirements for measuring radon gas exposures demand a lower detection limit of 50 kBq h m(-3), representing the Swiss concentration average of 70 Bq m(-3) over a 1-month period. A solid-state nuclear track detector (SSNTD) system (Politrack, Mi.am s.r.l., Italy) has been acquired to fulfil these requirements. This work was aimed at the calibration of the Politrack system with traceability to international standards and the development of a procedure to check the stability of the system. A total of 275 SSNTDs was exposed to 11 different radon exposures in the radon chamber of the Secondary Calibration Laboratory at the Paul Scherrer Institute, Switzerland. The exposures ranged from 50 to 15000 kBq h m(-3). For each exposure of 20 detectors, 5 SSNTDs were used to monitor possible background exposures during transport and storage. The response curve and the calibration factor of the whole system were determined using a Monte Carlo fitting procedure. A device to produce CR39 samples with a reference number of tracks using a (241)Am source was developed for checking the long-term stability of the Politrack system. The characteristic limits for the detection of a possible system drift were determined following ISO Standard 11929

    Hypericum perforatum treatment: effect on behaviour and neurogenesis in a chronic stress model in mice

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Extracts of <it>Hypericum perforatum </it>(St. John's wort) have been traditionally recommended for a wide range of medical conditions, in particular mild-to-moderate depression. The present study was designed to investigate the effect of Hypericum perforatum treatment in a mouse model of anxiety/depressive-like behavior, induced by chronic corticosterone administration.</p> <p>Methods</p> <p>CD1 mice were submitted to 7 weeks corticosterone administration and then behavioral tests as Open Field (OF), Novelty-Suppressed Feeding (NSF), Forced Swim Test (FST) were performed. Cell proliferation in hippocampal dentate gyrus (DG) was investigated by both 5-bromo-2'-deoxyuridine (BrdU) and doublecortin (DCX) immunohistochemistry techniques and stereological procedure was used to quantify labeled cells. Golgi-impregnation method was used to evaluate changes in dendritic spines in DG. Hypericum perforatum (30 mg/Kg) has been administered for 3 weeks and then neural development in the adult hippocampus and behavioral changes have been examined.</p> <p>Results</p> <p>The anxiety/depressive-like state due to chronic corticosterone treatment was reversed by exogenous administration of Hypericum perforatum; the proliferation of progenitor cells in mice hippocampus was significantly reduced under chronic corticosterone treatment, whereas a long term treatment with Hypericum perforatum prevented the corticosterone-induced decrease in hippocampal cell proliferation. Corticosterone-treated mice exhibited a reduced spine density that was ameliorated by Hypericum perforatum administration.</p> <p>Conclusion</p> <p>These results provide evidence of morphological adaptations occurring in mature hippocampal neurons that might underlie resilient responses to chronic stress and contribute to the therapeutic effects of chronic Hypericum perforatum treatment.</p

    Clinical and biochemical effects of a combination botanical product (ClearGuard™) for allergy: a pilot randomized double-blind placebo-controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Botanical products are frequently used for treatment of nasal allergy. Three of these substances, <it>Cinnamomum zeylanicum</it>, <it>Malpighia glabra</it>, and <it>Bidens pilosa</it>, have been shown to have a number of anti-allergic properties <it>in-vitro</it>. The current study was conducted to determine the effects of these combined ingredients upon the nasal response to allergen challenge in patients with seasonal allergic rhinitis.</p> <p>Methods</p> <p>Twenty subjects were randomized to receive the combination botanical product, (CBP) 2 tablets three times a day, loratadine, 10 mg once a day in the morning, or placebo, using a randomized, double-blinded crossover design. Following 2 days of each treatment and during the third day of treatment, subjects underwent a nasal allergen challenge (NAC), in which nasal symptoms were assessed after each challenge dose and every 2 hours for 8 hours. Nasal lavage fluid was assessed for tryptase, prostaglandin D2, and leukotriene E4 concentrations and inflammatory cells.</p> <p>Results</p> <p>Loratadine significantly reduced the total nasal symptom score during the NAC compared with placebo (P = 0.04) while the CBP did not. During the 8 hour period following NAC, loratadine and the CBP both reduced NSS compared with placebo (P = 0.034 and P = 0.029, respectively). Analysis of nasal lavage fluid demonstrated that the CBP prevented the increase in prostaglandin D2 release following NAC, while neither loratadine nor placebo had this effect. None of the treatments significantly affected tryptase or leukotriene E4 release or inflammatory cell infiltration.</p> <p>Conclusion</p> <p>The CBP significantly reduced NSS during the 8 hours following NAC and marginally inhibited the release of prostaglandin D2 into nasal lavage fluid, suggesting potential clinical utility in patients with allergic rhinitis.</p
    corecore