78 research outputs found

    Reconstructing the Optical Parameters of a Layered Medium with Optical Coherence Elastography

    Full text link
    In this work we consider the inverse problem of reconstructing the optical properties of a layered medium from an elastography measurement where optical coherence tomography is used as the imaging method. We hereby model the sample as a linear dielectric medium so that the imaging parameter is given by its electric susceptibility, which is a frequency- and depth-dependent parameter. Additionally to the layered structure (assumed to be valid at least in the small illuminated region), we allow for small scatterers which we consider to be randomly distributed, a situation which seems more realistic compared to purely homogeneous layers. We then show that a unique reconstruction of the susceptibility of the medium (after averaging over the small scatterers) can be achieved from optical coherence tomography measurements for different compression states of the medium.Comment: 19 pages, 1 figur

    Multidirectional Subspace Expansion for One-Parameter and Multiparameter Tikhonov Regularization

    Get PDF
    Tikhonov regularization is a popular method to approximate solutions of linear discrete ill-posed problems when the observed or measured data is contaminated by noise. Multiparameter Tikhonov regularization may improve the quality of the computed approximate solutions. We propose a new iterative method for large-scale multiparameter Tikhonov regularization with general regularization operators based on a multidirectional subspace expansion. The multidirectional subspace expansion may be combined with subspace truncation to avoid excessive growth of the search space. Furthermore, we introduce a simple and effective parameter selection strategy based on the discrepancy principle and related to perturbation results

    Mathematical Modelling of Optical Coherence Tomography

    Full text link
    In this chapter a general mathematical model of Optical Coherence Tomography (OCT) is presented on the basis of the electromagnetic theory. OCT produces high resolution images of the inner structure of biological tissues. Images are obtained by measuring the time delay and the intensity of the backscattered light from the sample considering also the coherence properties of light. The scattering problem is considered for a weakly scattering medium located far enough from the detector. The inverse problem is to reconstruct the susceptibility of the medium given the measurements for different positions of the mirror. Different approaches are addressed depending on the different assumptions made about the optical properties of the sample. This procedure is applied to a full field OCT system and an extension to standard (time and frequency domain) OCT is briefly presented.Comment: 28 pages, 5 figures, book chapte

    Comparison of the marginal adaptation of direct and indirect composite inlay restorations with optical coherence tomography

    Get PDF
    OBJECTIVE: The purpose of the study was to use the photonic imaging modality of optical coherence tomography (OCT) to compare the marginal adaptation of composite inlays fabricated by direct and indirect techniques. MATERIAL AND METHODS: Class II cavities were prepared on 34 extracted human molar teeth. The cavities were randomly divided into two groups according to the inlay fabrication technique. The first group was directly restored on cavities with a composite (Esthet X HD, Dentsply, Germany) after isolating. The second group was indirectly restored with the same composite material. Marginal adaptations were scanned before cementation with an invisible infrared light beam of OCT (Thorlabs), allowing measurement in 200 µm intervals. Restorations were cemented with a self-adhesive cement resin (SmartCem2, Dentsply), and then marginal adaptations were again measured with OCT. Mean values were statistically compared by using independent-samples t-test and paired samples t-test (p<0.05), before and after cementation. RESULTS: Direct inlays presented statistically smaller marginal discrepancy values than indirect inlays, before (p=0.00001442) and after (p=0.00001466) cementation. Marginal discrepancy values were increased for all restorations after cementation (p=0.00008839, p=0.000000952 for direct and indirect inlays, respectively). The mean marginal discrepancy value of the direct group increased from 56.88±20.04 µm to 91.88±31.7 µm, whereas the indirect group increased from 107.54±35.63 µm to 170.29±54.83 µm. Different techniques are available to detect marginal adaptation of restorations, but the OCT system can give quantitative information about resin cement thickness and its interaction between tooth and restoration in a nondestructive manner. CONCLUSIONS: Direct inlays presented smaller marginal discrepancy than indirect inlays. The marginal discrepancy values were increased for all restorations that refer to cement thickness after cementation

    High-resolution intravascular magnetic resonance quantification of atherosclerotic plaque at 3T

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The thickness of fibrous caps (FCT) of atherosclerotic lesions is a critical factor affecting plaque vulnerability to rupture. This study tests whether 3 Tesla high-resolution intravascular cardiovascular magnetic resonance (CMR) employing tiny loopless detectors can identify lesions and accurately measure FCT in human arterial specimens, and whether such an approach is feasible <it>in vivo </it>using animal models.</p> <p>Methods</p> <p>Receive-only 2.2 mm and 0.8 mm diameter intravascular loopless CMR detectors were fabricated for a clinical 3 Tesla MR scanner, and the absolute signal-to-noise ratio determined. The detectors were applied in a two-step protocol comprised of CMR angiography to identify atherosclerotic lesions, followed by high-resolution CMR to characterize FCT, lesion size, and/or vessel wall thickness. The protocol was applied in fresh human iliac and carotid artery specimens in a human-equivalent saline bath. Mean FCT measured by 80 μm intravascular CMR was compared with histology of the same sections. <it>In vivo </it>studies compared aortic wall thickness and plaque size in healthy and hyperlipidemic rabbit models, with post-mortem histology.</p> <p>Results</p> <p>Histology confirmed plaques in human specimens, with calcifications appearing as signal voids. Mean FCT agreed with histological measurements within 13% on average (correlation coefficient, <it>R </it>= 0.98; Bland-Altman analysis, -1.3 ± 68.9 μm). <it>In vivo </it>aortic wall and plaque size measured by 80 μm intravascular CMR agreed with histology.</p> <p>Conclusion</p> <p>Intravascular 3T CMR with loopless detectors can both locate atherosclerotic lesions, and accurately measure FCT at high-resolution in a strategy that appears feasible <it>in vivo</it>. The approach shows promise for quantifying vulnerable plaque for evaluating experimental therapies.</p

    Corticosteroid suppression of lipoxin A4 and leukotriene B4from alveolar macrophages in severe asthma

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>An imbalance in the generation of pro-inflammatory leukotrienes, and counter-regulatory lipoxins is present in severe asthma. We measured leukotriene B<sub>4 </sub>(LTB<sub>4</sub>), and lipoxin A<sub>4 </sub>(LXA<sub>4</sub>) production by alveolar macrophages (AMs) and studied the impact of corticosteroids.</p> <p>Methods</p> <p>AMs obtained by fiberoptic bronchoscopy from 14 non-asthmatics, 12 non-severe and 11 severe asthmatics were stimulated with lipopolysaccharide (LPS,10 μg/ml) with or without dexamethasone (10<sup>-6</sup>M). LTB<sub>4 </sub>and LXA<sub>4 </sub>were measured by enzyme immunoassay.</p> <p>Results</p> <p>LXA<sub>4 </sub>biosynthesis was decreased from severe asthma AMs compared to non-severe (p < 0.05) and normal subjects (p < 0.001). LXA<sub>4 </sub>induced by LPS was highest in normal subjects and lowest in severe asthmatics (p < 0.01). Basal levels of LTB<sub>4 </sub>were decreased in severe asthmatics compared to normal subjects (p < 0.05), but not to non-severe asthma. LPS-induced LTB<sub>4 </sub>was increased in severe asthma compared to non-severe asthma (p < 0.05). Dexamethasone inhibited LPS-induced LTB<sub>4 </sub>and LXA<sub>4</sub>, with lesser suppression of LTB<sub>4 </sub>in severe asthma patients (p < 0.05). There was a significant correlation between LPS-induced LXA<sub>4 </sub>and FEV<sub>1 </sub>(% predicted) (r<sub>s </sub>= 0.60; p < 0.01).</p> <p>Conclusions</p> <p>Decreased LXA<sub>4 </sub>and increased LTB<sub>4 </sub>generation plus impaired corticosteroid sensitivity of LPS-induced LTB<sub>4 </sub>but not of LXA<sub>4 </sub>support a role for AMs in establishing a pro-inflammatory balance in severe asthma.</p

    Optical coherence tomography—current technology and applications in clinical and biomedical research

    Get PDF
    corecore