    American College of Cardiology/ European Society of Cardiology international study of angiographic data compression phase III Measurement of image quality differences at varying levels of data compression

    Get PDF
    AbstractOBJECTIVESWe sought to investigate up to which level of Joint Photographic Experts Group (JPEG) data compression the perceived image quality and the detection of diagnostic features remain equivalent to the quality and detectability found in uncompressed coronary angiograms.BACKGROUNDDigital coronary angiograms represent an enormous amount of data and therefore require costly computerized communication and archiving systems. Earlier studies on the viability of medical image compression were not fully conclusive.METHODSTwenty-one raters evaluated sets of 91 cine runs. Uncompressed and compressed versions of the images were presented side by side on one monitor, and image quality differences were assessed on a scale featuring six scores. In addition, the raters had to detect pre-defined clinical features. Compression ratios (CR) were 6:1, 10:1 and 16:1. Statistical evaluation was based on descriptive statistics and on the equivalence t-test.RESULTSAt the lowest CR (CR 6:1), there was already a small (15%) increase in assigning the aesthetic quality score indicating “quality difference is barely discernible—the images are equivalent.” At CR 10:1 and CR 16:1, close to 10% and 55%, respectively, of the compressed images were rated to be “clearly degraded, but still adequate for clinical use” or worse. Concerning diagnostic features, at CR 10:1 and CR 16:1 the error rate was 9.6% and 13.1%, respectively, compared with 9% for the baseline error rate in uncompressed images.CONCLUSIONSCompression at CR 6:1 provides equivalence with the original cine runs. If CR 16:1 were used, one would have to tolerate a significant increase in the diagnostic error rate over the baseline error rate. At CR 10:1, intermediate results were obtained

    Lossy JPEG Compression in Quantitative Angiography: the Role of X-ray Quantum Noise

    No full text
    In medical imaging, contrary to applications in the consumer market, the use of irreversible or lossy compression is still in its beginnings. This is due to the suspected risk of compromising the diagnostic content. Many studies have been performed, but it was not until 2008 that national activities in different countries resulted in recommendations for the safe use of irreversible image compression in clinical practice. Quantitative coronary angiography (QCA), however, poses a special problem, since here a large variation in published maximum compression factors has strengthened the general concerns about the use of lossy techniques. Up to now, the reason for the variation has not been thoroughly investigated. Reasons for the discrepancies in published compression factors are determined in this study. Since JPEG compression reduces the quantum noise of the X-ray images, the impact of compression is overestimated when interpreting any change in local diameter as an error. By taking into consideration the quantitative effect of quantum noise in QCA, it is shown that the influence of JPEG compression can be neglected for compression factors up to ten at clinically applicable X-ray doses. This limit is comparable to that found by visual analysis for aesthetic image quality. Future studies on image compression effects should take the interaction with quantum noise explicitly into consideration

    Impact of ecologically relevant heat shocks on Hsp developmental function in the vetigastropod Haliotis asinina

    No full text
    Heat shock proteins (Hsps) are essential for cellular maintenance, normal differentiation and morphogenesis, and protection against a range of environmental stresses. It is unknown which of these roles takes precedence when they are required simultaneously. Here we examined the impact of thermal stress on the complex developmental expression patterns of HasHsp70 and HasHsp90A in the vetigastropod Haliotis asinina. We find that near-lethal heat shocks do not alter the spatial demarcation of Hsp expression despite such treatments impacting on the external character of the embryos. Using a suite of molecular markers that are both coexpressed with the Hsps (i.e. in ventrolateral ectoderm and prototroch) and expressed in tissues that have lower (basal) Hsp expression (e.g. serotonergic nervous system and shell gland), we determined that Hsp-expressing tissues do not incur markedly less thermal damage than adjacent tissues. To explore the relationship of Hsp expression with sensitivity of specific cell territories to heat shock, we focused on the formation of the prototroch, a tissue where HasHsp70 and HasHsp90A are coexpressed. By heat shocking at specific developmental stages, we determined that the most sensitive period of prototroch development is during its early specification and differentiation, which overlaps with the time the Hsps are expressed at their highest levels in these cells. This correlation is consistent with heat shock impairing the function of Hsps in regions of the H. asinina embryo undergoing morphogenesis
    corecore