46 research outputs found

    All-In-One: Advanced preparation of Human Parenchymal and Non-Parenchymal Liver Cells

    Get PDF
    BACKGROUND & AIMS: Liver cells are key players in innate immunity. Thus, studying primary isolated liver cells is necessary for determining their role in liver physiology and pathophysiology. In particular, the quantity and quality of isolated cells are crucial to their function. Our aim was to isolate a large quantity of high-quality human parenchymal and non-parenchymal cells from a single liver specimen. METHODS: Hepatocytes, Kupffer cells, liver sinusoidal endothelial cells, and stellate cells were isolated from liver tissues by collagenase perfusion in combination with low-speed centrifugation, density gradient centrifugation, and magnetic-activated cell sorting. The purity and functionality of cultured cell populations were controlled by determining their morphology, discriminative cell marker expression, and functional activity. RESULTS: Cell preparation yielded the following cell counts per gram of liver tissue: 2.0+/-0.4x107 hepatocytes, 1.8+/-0.5x106 Kupffer cells, 4.3+/-1.9x105 liver sinusoidal endothelial cells, and 3.2+/-0.5x105 stellate cells. Hepatocytes were identified by albumin (95.5+/-1.7%) and exhibited time-dependent activity of cytochrome P450 enzymes. Kupffer cells expressed CD68 (94.5+/-1.2%) and exhibited phagocytic activity, as determined with 1mum latex beads. Endothelial cells were CD146+ (97.8+/-1.1%) and exhibited efficient uptake of acetylated low-density lipoprotein. Hepatic stellate cells were identified by the expression of alpha-smooth muscle actin (97.1+/-1.5%). These cells further exhibited retinol (vitamin A)-mediated autofluorescence. CONCLUSIONS: Our isolation procedure for primary parenchymal and non-parenchymal liver cells resulted in cell populations of high purity and quality, with retained physiological functionality in vitro. Thus, this system may provide a valuable tool for determining liver function and disease

    Endothelial Stomatal and Fenestral Diaphragms in Normal Vessels and Angiogenesis

    Get PDF
    Vascular endothelium lines the entire cardiovascular system where performs a series of vital functions including the control of microvascular permeability, coagulation inflammation, vascular tone as well as the formation of new vessels via vasculogenesis and angiogenesis in normal and disease states. Normal endothelium consists of heterogeneous populations of cells differentiated according to the vascular bed and segment of the vascular tree where they occur. One of the cardinal features is the expression of specific subcellular structures such as plasmalemmal vesicles or caveolae, transendothelial channels, vesiculo-vacuolar organelles, endothelial pockets and fenestrae, whose presence define several endothelial morphological types. A less explored observation is the differential expression of such structures in diverse settings of angiogenesis. This review will focus on the latest developments on the components, structure and function of these specific endothelial structures in normal endothelium as well as in diverse settings of angiogenesis

    AFM imaging of fenestrated liver sinusoidal endothelial cells

    No full text
    Each microscope with its dedicated sample preparation technique provides the investigator with a specific set of data giving an instrument-determined (or restricted) insight into the structure and function of a tissue, a cell or parts thereof. Stepwise improvements in existing techniques, both instrumental and preparative, can sometimes cross barriers in resolution and image quality. Of course, investigators get really excited when completely new principles of microscopy and imaging are offered in promising new instruments, such as the AFM. The present paper summarizes a first phase of studies on the thin endothelial cells of the liver. It describes the preparation-dependent differences in AFM imaging of these cells after isolation. Special point of interest concerned the dynamics of the fenestrae, thought to filter lipid-carrying particles during their transport from the blood to the liver cells. It also describes the attempts to image the details of these cells when alive in cell cultures. It explains what physical conditions, mainly contributed to the scanning stylus, are thought to play a part in the limitations in imaging these cells. The AFM also offers promising specifications to those interested in cell surface details, such as membrane-associated structures, receptors, coated pits, cellular junctions and molecular aggregations or domains. The AFM also offers nano-manipulation possibilities, strengths and elasticity measurements, force interactions, affinity measurements, stiffness and other physical aspects of membranes and cytoskeleton. The potential for molecular approaches is there. New developments in cantilever construction and computer software promise to bring real time video imaging to the AFM. Home made accessories for the first generation of AFM are now commodities in commercial instruments and make the life of the AFM microscopist easier. Also, the combination of different microscopies, such as AFM and TEM, or AFM and SEM find their way to the market allowing comfortable correlative microscopy

    Three-dimensional ultrastructure of giant mitochondria in human non-alcoholic fatty liver disease.

    Get PDF
    Giant mitochondria are peculiarly shaped, extremely large mitochondria in hepatic parenchymal cells, the internal structure of which is characterised by atypically arranged cristae, enlarged matrix granules and crystalline inclusions. The presence of giant mitochondria in human tissue biopsies is often linked with cellular adversity, caused by toxins such as alcohol, xenobiotics, anti-cancer drugs, free-radicals, nutritional deficiencies or as a consequence of high fat Western diets. To date, non-alcoholic fatty liver disease is the most prevalent liver disease in lipid dysmetabolism, in which mitochondrial dysfunction plays a crucial role. It is not well understood whether the morphologic characteristics of giant mitochondria are an adaption or caused by such dysfunction. In the present study, we employ a complementary multimodal imaging approach involving array tomography and transmission electron tomography in order to comparatively analyse the structure and morphometric parameters of thousands of normal- and giant mitochondria in four patients diagnosed with non-alcoholic fatty liver disease. In so doing, we reveal functional alterations associated with mitochondrial gigantism and propose a mechanism for their formation based on our ultrastructural findings

    Comparison of fixed and living liver endothelial cells by atomic force microscopy

    No full text

    Endothelial and pit cells

    No full text
    info:eu-repo/semantics/publishe

    Early detection of cytotoxic events between hepatic natural killer cells and colon carcinoma cells as probed with the atomic force microscope.

    No full text
    The atomic force microscope (AFM) is a powerful tool to investigate surface and submembranous structures of living cells under physiological conditions at high resolution. These properties enabled us to study the interaction between live hepatic natural killer (NK) cells, also called pit cells, and colon carcinoma cells in vitro by AFM. In addition, the staining for filamentous actin and DNA was performed and served as a reference, because actin and nuclear observations at the light microscopic level during the cytotoxic interaction between these two cell types have been presented earlier. In this study, we collected evidence that conjugation of hepatic NK cells with CC531s colon carcinoma cells results in a decreased binding of CC531s cells to the substratum as probed with the AFM in contact mode as early as 10 min after cell contact (n = 11). To avoid the lateral forces and smearing artefacts of contact mode AFM, non-contact imaging was performed on hepatic NK/CC531s cell conjugates, resulting in identical observations (n = 3). In contrast, the first cytotoxic signs, as determined with the nuclear staining dye Hoechst 33342, could be observed 3 h after the start of the co-culture. This study illustrates that the AFM can be used to probe early cytotoxic effects of effector to target cell contact in nearby physiological conditions. Other routine cytotoxicity tests detect the first cytotoxic effects after 1.5-3 h co-incubation at the earliest.Journal ArticleResearch Support, Non-U.S. Gov'tinfo:eu-repo/semantics/publishe

    Tracing DiO-labelled tumour cells in liver sections by confocal laser scanning microscopy.

    No full text
    Investigating rare cellular events is facilitated by studying thick sections with confocal laser scanning microscopy (CLSM). Localization of cells in tissue sections can be done by immunolabelling or by fluorescent labelling of cells prior to intravenous administration. Immunolabelling is technically complicated because of the preservation of antigens during fixation and the problems associated with the penetration of the antibodies. In this study, an alternative and simple approach for the labelling of cells in vitro with the fluorescent probe DiO and its subsequent application in vivo will be outlined. The method was applied to trace DiO-labelled colon carcinoma cells (CC531s) in 100 microm thick liver sections. In vitro and in vivo experiments revealed that DiO-labelling of CC531s cells had no cytotoxic or antiproliferative effect and the cells preserved their susceptibility towards hepatic NK cells or Kupffer cells. In addition, DiO remained stable for at least 72 h in the living cell. DiO-labelled CC531s cells could be traced all over the tissue depth and anti-metastatic events such as phagocytosis of tumour cells by Kupffer cells could be easily observed. In situ staining with propidium iodide (nucleic acids) or rhodamine-phalloidin (filamentous actin) resulted in additional tissue information. The data presented improved the understanding of the possible effects of the vital fluorescent probe DiO on cell function and provided a limit of confidence for CLSM imaging of DiO-labelled cells in tissue sections.In VitroJournal ArticleResearch Support, Non-U.S. Gov'tSCOPUS: ar.jFLWINinfo:eu-repo/semantics/publishe
    corecore