53 research outputs found

    Clinician’s awareness and knowledge on the management of differentiated thyroid cancer and the use of radioactive iodine in Tanzania

    Get PDF
    Introduction: Thyroid cancer is the most common endocrine malignancy worldwide with better outcome if timely and properly managed. Surgery followed by radioactive iodine (RAI) ablation remains the mainstay in the management of differentiated thyroid cancer (DTC). In Tanzania however, few patients with DTC receive RAI ablation post-surgery, and most of these present late, with advanced disease resulting in poor treatment outcome. The objective of this study was to determine the course for late referral by assessing clinician’s awareness and knowledge on the management of DTC and the use of RAI in Tanzania.Methods: This descriptive cross sectional study was carried out in referral hospitals in Tanzania. Data collection used a standardized self-administered questionnaire. Information sought included awareness, knowledge and practices of clinicians on the management and the use of RAI on patients with DTC was explored.Results: Majority of clinicians managing DTC patients were males (86%), in-training surgeons (54%), and attended less than ten DTC patients per year (62%). About 44% of in-training surgeons never heard of nuclear medicine (p=0.04), and 20% were not aware of the role of RAI in the management of DTC (p=0.031). Only 7.3% of surgeons were aware of the role of thyroxine therapy, or RAI ablation post-surgery. Of all DTC patients managed surgically, only 16% had total thyroidectomy with lymphadenectomy (p=0.05).Conclusion: The findings of this study indicate there is insufficient knowledge on proper management and use of RAI on patients with DTC among clinicians in Tanzania

    96. Ganglion sentinelle du bras

    Get PDF

    WFPC2 Observations of Compact Star Cluster Nuclei in Low Luminosity Spiral Galaxies

    Get PDF
    We have used the Wide Field Planetary Camera 2 aboard the Hubble Space Telescope to image the compact star cluster nuclei of the nearby, late-type, low-luminosity spiral galaxies NGC 4395, NGC 4242, and ESO 359-029. We also analyze archival WFPC2 observations of the compact star cluster nucleus of M33. A comparative analysis of the structural and photometric properties of these four nuclei is presented. All of the nuclei are very compact, with luminosity densities increasing at small radii to the resolution limit of our data. NGC 4395 contains a Seyfert 1 nucleus with a distinct bipolar structure and bright associated filaments which are likely due to [OIII] emission. The M33 nucleus has a complex structure, with elongated isophotes and possible signatures of weak activity, including a jet-like component. The other two nuclei are not known to be active, but share similar physical size scales and luminosities to the M33 and NGC 4395 nuclei. The circumnuclear environments of all four of our program galaxies are extremely diffuse, have only low-to-moderate star formation, and appear to be devoid of large quantities of dust. The central gravitational potentials of the galaxies are also quite shallow, making the origin of these types of `naked' nuclei problematic.Comment: to appear in the July 1999 Astronomical Journal; 38 pages (Latex), 5 tables (postscript), 21 figures (gif); postscript versions of the figures may be obtained via anonymous ftp at ftp://ftp.cv.nrao.edu/NRAO-staff/lmatthew/lanl-nucle

    Worldwide diagnostic reference levels for single-photon emission computed tomography myocardial perfusion imaging: findings from INCAPS.

    Get PDF
    OBJECTIVES: This study sought to establish worldwide and regional diagnostic reference levels (DRLs) and achievable administered activities (AAAs) for single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). BACKGROUND: Reference levels serve as radiation dose benchmarks to compare individual laboratories against aggregated data, helping to identify sites in greatest need of dose reduction interventions. DRLs for SPECT MPI have previously been derived from national or regional registries. To date there have been no multiregional reports of DRLs for SPECT MPI from a single standardized dataset. METHODS: Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study), a cross-sectional, multinational registry of MPI protocols. A total of 7,103 studies were included. DRLs and AAAs were calculated by protocol for each world region and for aggregated worldwide data. RESULTS: The aggregated worldwide DRLs for rest-stress or stress-rest studies employing technetium Tc 99m-labeled radiopharmaceuticals were 11.2 mCi (first dose) and 32.0 mCi (second dose) for 1-day protocols, and 23.0 mCi (first dose) and 24.0 mCi (second dose) for multiday protocols. Corresponding AAAs were 10.1 mCi (first dose) and 28.0 mCi (second dose) for 1-day protocols, and 17.8 mCi (first dose) and 18.7 mCi (second dose) for multiday protocols. For stress-only technetium Tc 99m studies, the worldwide DRL and AAA were 18.0 mCi and 12.5 mCi, respectively. Stress-first imaging was used in 26% to 92% of regional studies except in North America where it was used in just 7% of cases. Significant differences in DRLs and AAAs were observed between regions. CONCLUSIONS: This study reports reference levels for SPECT MPI for each major world region from one of the largest international registries of clinical MPI studies. Regional DRLs may be useful in establishing or revising guidelines or simply comparing individual laboratory protocols to regional trends. Organizations should continue to focus on establishing standardized reporting methods to improve the validity and comparability of regional DRLs

    Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS)

    Get PDF
    Aims To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing ‘best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. Methods and results We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight ‘best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≀ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more ‘best practices' had lower EDs. Conclusion Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globall

    Current worldwide nuclear cardiology practices and radiation exposure : results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS)

    Get PDF
    To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≀ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs. Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally

    Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world

    Get PDF
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection

    Initial report back of the International Atomic Energy Agency audit of nuclear medicine in Africa

    No full text
    Please help us populate SUNScholar with the post print version of this article. It can be e-mailed to: [email protected]

    Interactive Deconvolution with Error Analysis

    No full text
    Not Availabl
    • 

    corecore