7 research outputs found

    Sedimentation processes in a coral reef embayment : Hanalei Bay, Kauai

    Get PDF
    This paper is not subject to U.S. copyright. The definitive version was published in Marine Geology 264 (2009): 140-151, doi:10.1016/j.margeo.2009.05.002.Oceanographic measurements and sediment samples were collected during the summer of 2006 as part of a multi-year study of coastal circulation and the fate of terrigenous sediment on coral reefs in Hanalei Bay, Kauai. The goal of this study was to better understand sediment dynamics in a coral reef-lined embayment where winds, ocean surface waves, and river floods are important processes. During a summer period that was marked by two wave events and one river flood, we documented significant differences in sediment trap collection rates and the composition, grain size, and magnitude of sediment transported in the bay. Sediment trap collection rates were well correlated with combined wave-current near-bed shear stresses during the non-flood periods but were not correlated during the flood. The flood's delivery of fine-grained sediment to the bay initially caused high turbidity and sediment collection rates off the river mouth but the plume dispersed relatively quickly. Over the next month, the flood deposit was reworked by mild waves and currents and the fine-grained terrestrial sediment was advected around the bay and collected in sediment traps away from the river mouth, long after the turbid surface plume was gone. The reworked flood deposits, due to their longer duration of influence and proximity to the seabed, appear to pose a greater long-term impact to benthic coral reef communities than the flood plumes themselves. The results presented here display how spatial and temporal differences in hydrodynamic processes, which result from variations in reef morphology and orientation, cause substantial variations in the deposition, residence time, resuspension, and advection of both reef-derived and fluvial sediment over relatively short spatial scales in a coral reef embayment

    Comparison between a Novel Radiofrequency-Balloon and a Standard Cryo-Balloon in Pulmonary Vein Isolation: A Propensity-Score-Matched Analysis

    No full text
    Background/Objectives: Single-shot devices are important tools for efficient pulmonary vein isolation (PVI) in atrial fibrillation (AF). In addition to the standard cryo-balloon (CB) catheter, a novel multi-electrode radiofrequency balloon-catheter (RFB, Heliostar, Biosense Webster, Irvine, CA, USA) with 3D-mapping-integration is available. Currently, there is no evidence allowing for a direct comparison between RFB-PVI and CB-PVI in a matched population. The study aimed to assess the procedural data, safety profiles, and outcomes of RFB-PVI versus CB-PVI. Methods: In this prospective registry study, symptomatic AF patients undergoing first-time PVI from January 2019 to April 2023, using RFB or CB, were included, with patients matched in a 1:2 ratio to reduce potential confounders. Results: The results from 171 consecutive RFB patients and 342 matched CB patients showed comparable recurrence-free survival after 12 months (81.3% RFB vs. 76.8% CB, p = 0.359). The RFB group had a longer procedure duration (88 vs. 73 min, p p Conclusions: In conclusion, the novel RFB system enables efficient and safe PVI, which is broadly comparable to the established CB system. However, the 3D-mapping integration in RFB did not reduce fluoroscopy time compared to CB

    Impact of re-definition of paroxysmal and persistent atrial fibrillation in the 2012 and 2016 European Society of Cardiology atrial fibrillation guidelines on outcomes after pulmonary vein isolation

    No full text
    Purpose!#!In the 2016 European Society of Cardiology (ESC) guidelines for the management of atrial fibrillation (AF), the definition of AF type has been modified compared with the 2010 guidelines and its 2012 focused update. We compared the difference of single procedure outcomes using the definitions before and after 2016 on a cohort of patients with AF undergoing AF ablation.!##!Methods!#!Consecutive AF ablation patients with paroxysmal or persistent AF were retrospectively reclassified applying the 2010, 2012, and 2016 ESC definitions on AF type.!##!Results!#!We included a total of 628 patients. Applying the 2010 ESC AF guidelines definition, 68% of patients were paroxysmal while according to the 2016 ESC AF guidelines, the proportion increased to 87%. Applying the 2010 ESC guidelines definition, recurrence rates of paroxysmal and persistent AF patients differ significantly (log-rank p < 0.001). Applying the 2012 focused update and the 2016 ESC AF guidelines, recurrence rates do not differ significantly. In a cox regression model applying the 2010 guidelines, persistent AF is the only independent predictor of AF recurrence in our cohort. However, when applying the 2016 guidelines, persistent AF is no longer a predictor of AF recurrence.!##!Conclusions!#!The revised definition of AF types in the 2016 ESC AF guidelines leads to a marked shift from persistent to paroxysmal AF. It appears that the old definition provided a better separator to predict rhythm outcome after AF ablation

    Safety of conscious sedation in electroanatomical mapping procedures and cryoballoon pulmonary vein isolation

    No full text
    Immobilization of patients during electrophysiological procedures, to avoid complications by patients' unexpected bodily motion, is achieved by moderate to deep conscious sedation using benzodiazepines and propofol for sedation and opioids for analgesia. Our aim was to compare respiratory and hemodynamic safety endpoints of cryoballoon pulmonary vein isolation (PVI) and electroanatomical mapping (EAM) procedures. Included patients underwent either cryoballoon PVI or EAM procedures. Sedation monitoring included non-invasive blood pressure measurements, transcutaneous oxygen saturation (tSp

    Incidence of Long-Term Pulmonary Vein Reconnection after a 2-Minute Cryoballoon Freeze for Pulmonary Vein Isolation—Invasive Insights of TTI-Dependent Cryoenergy Titration

    No full text
    Introduction: The optimal freeze duration in cryoballoon pulmonary vein isolation (PVI) is unknown. TTI-based titration of cryoenergy allows individualized freeze duration and has emerged as a favorable ablation strategy in PV cryoablation. In a recent study, we demonstrated that omission of a bonus freeze and reduction in freeze duration to a minimum of 2 min in the case of short TTI led to comparable arrhythmia recurrence rates. Whereas clinical outcome seems to be comparable to fixed freeze duration, evidence of long-term PV reconnection rates in patients undergoing TTI-based cryoballoon ablation is sparse. Aim of the study: To evaluate the procedural efficacy of a single 2-min freeze for PVI, we assessed PV conduction recovery after cryoballoon PVI with a TTI-guided titration of freeze duration compared to a fixed ablation protocol. Methods and Results: We included consecutive patients with atrial fibrillation (AF) recurrence undergoing a second ablation procedure after the initial cryoballoon procedure. The second AF ablation procedure was performed by the 3D-mapping system and radiofrequency ablation technique. A total of 219 patients (age: 66.2 ± 10.8 years, 53% female, paroxysmal AF: 53%) treated with the TTI-guided protocol (174 patients, 685 PV) or fixed protocol (45 patients, 179 PV) showed comparable total reconnection rates (TTI: 36.9% vs. fixed: 31.8%, p = 0.21). The PV reconnection rate was not statistically different for PVs treated with a 2-min freeze in case of short TTI, compared to longer freeze duration. Interestingly, the PV reconnection rate was lower in LIPVs treated with the fixed protocol (13% vs. 31%, p = 0.029). In the TTI group, 17 out of 127 patients (15%) had durable isolation of all PVs, whereas in 8 out of 40 patients (20%) in the fixed group, all PVs were still isolated (p = 0.31). Conclusions: overall reconnection rate was not different using a TTI-guided ablation protocol compared to a fixed ablation protocol, whereas the LIPV reconnection rate was significantly lower in patients treated with a fixed ablation protocol
    corecore