214 research outputs found

    UNOLS establishes SCOAR to promote research aircraft facilities for U.S. ocean sciences

    Get PDF
    The ocean sciences community is currently engaged in the process of defining new facilities that will support oceanographic research, education, and monitoring efforts for the next several decades. New research vessels, drilling ships, coastal and deep-ocean observing systems, satellites, and submersibles will be designed to increase ocean access in terms of geographical coverage, depth, temporal continuity, and resolution of events. Aircraft may be largely overlooked facilities that are capable of providing observations and data in ways that satisfy many research goals, and they should be considered an important component in the future mix of oceanographic facilities

    Gas Dynamic Virtual Nozzle for Generation of Microscopic Droplet Streams

    Full text link
    As shown by Ganan-Calvo and co-workers, a free liquid jet can be compressed in iameter through gas-dynamic forces exerted by a co-flowing gas, obviating the need for a solid nozzle to form a microscopic liquid jet and thereby alleviating the clogging problems that plague conventional droplet sources of small diameter. We describe in this paper a novel form of droplet beam source based on this principle. The source is miniature, robust, dependable, easily fabricated, and eminently suitable for delivery of microscopic liquid droplets, including hydrated biological samples, into vacuum for analysis using vacuum instrumentation. Monodisperse, single file droplet streams are generated by triggering the device with a piezoelectric actuator. The device is essentially immune to clogging

    Prevalence, evaluation and management of overactive bladder in primary care

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Patients with overactive bladder (OAB) are under-diagnosed in the primary care setting. Primary care physicians (PCP) approach to the patient and appropriate patient disclosure may contribute to under-diagnosis.</p> <p>Methods</p> <p>An outpatient primary care setting was used to determine the prevalence and characteristics of OAB. Patients who visited the family medicine outpatient clinic were invited to answer a self-administered questionnaire. It included questions on evidence of lower urinary tract symptoms (modified Overactive Bladder-Validated 8-question Screener [OAB-V8]), relevant medical and surgical history, and demographic data. Relationship between OAB and other independent variables were analyzed using chi-square and risk ratio (RR) analysis.</p> <p>Results</p> <p>Of 325 questionnaires distributed, 311 were returned completed. Patients ranged from 18 to 97 years, the majority women (74.0%) and African American (74.3%). OAB was present in 60.5% of men and 48.3% of women (<it>p </it>= 0.058). OAB was significantly associated with obesity (BMI > = 30) in women (<it>p </it>= 0.018, RR = 1.72), specifically obese premenopausal women (age < 55 years) (<it>p </it>= 0.011, RR = 1.98).</p> <p>Conclusion</p> <p>OAB prevalence is more than double and higher in men than previously reported. The relative risk for OAB is significantly greater in obese premenopausal women.</p

    A comparison of Power Doppler with conventional sonographic imaging for the evaluation of renal artery stenosis

    Get PDF
    BACKGROUND: Power Doppler (PD) has improved diagnostic capabilities of vascular sonography, mainly because it is independent from the angle of insonation. We evaluated this technique in a prospective comparison with conventional imaging, consisting in Duplex and Color Doppler, for the evaluation of Renal Artery (RA) stenosis. METHODS: Sensitivity, specificity and predictive values of PD and conventional imaging were assessed in a blinded fashion on eighteen patients, 9 with angiographic evidence of unilateral RA stenosis (hypertensive patients) and 9 with angiographically normal arteries (control group). PD images were interpreted with an angiography-like criteria. RESULTS: In the control group both techniques allowed correct visualization of 16 out of the 18 normal arteries (93% specificity). Only in five hypertensive patients RA stenosis was correctly identified with conventional technique (56% sensitivity and 86% negative predictive value); PD was successful in all hypertensive patients (100% sensitivity and negative predictive value), since the operators could obtain in each case of RA stenosis a sharp color signal of the whole vessel with a clear "minus" at the point of narrowing of the lumen. All results were statistically significant (p < 0.01). CONCLUSIONS: This study demonstrates that PD is superior to conventional imaging, in terms of sensitivity and specificity, for the diagnosis of RA stenosis, because it allows a clear visualization of the whole stenotic vascular lumen. Especially if it is used in concert with the other sonographic techniques, PD can enable a more accurate imaging of renovascular disease with results that seem comparable to selective angiography

    Diclofenac Hypersensitivity: Antibody Responses to the Parent Drug and Relevant Metabolites

    Get PDF
    Background: Hypersensitivity reactions against nonsteroidal antiinflammatory drugs (NSAIDs) like diclofenac (DF) can manifest as Type I-like allergic reactions including systemic anaphylaxis. However, except for isolated case studies experimental evidence for an IgE-mediated pathomechanism of DF hypersensitivity is lacking. In this study we aimed to investigate the possible involvement of drug-and/or metabolite-specific antibodies in selective DF hypersensitivity. Methodology/Principal Findings: DF, an organochemically synthesized linkage variant, and five major Phase I metabolites were covalently coupled to carrier proteins. Drug conjugates were analyzed for coupling degree and capacity to crosslink receptor-bound IgE antibodies from drug-sensitized mice. With these conjugates, the presence of hapten-specific IgE antibodies was investigated in patients' samples by ELISA, mediator release assay, and basophil activation test. Production of sulfidoleukotrienes by drug conjugates was determined in PBMCs from DF-hypersensitive patients. All conjugates were shown to carry more than two haptens per carrier molecule. Immunization of mice with drug conjugates induced drug-specific IgE antibodies capable of triggering mediator release. Therefore, the conjugates are suitable tools for detection of drug-specific antibodies and for determination of their anaphylactic activity. Fifty-nine patients were enrolled and categorized as hypersensitive either selectively to DF or to multiple NSAIDs. In none of the patients' samples evidence for drug/metabolite-specific IgE in serum or bound to allergic effector cells was found. In contrast, a small group of patients (8/59, 14%) displayed drug/metabolite-specific IgG. Conclusions/Significance: We found no evidence for an IgE-mediated effector mechanism based on haptenation of protein carriers in DF-hypersensitive patients. Furthermore, a potential involvement of the most relevant metabolites in DF hypersensitivity reactions could be excluded

    The role of routine post-natal abdominal ultrasound for newborns in a resource-poor setting: a longitudinal study

    Get PDF
    <p>Abstract</p> <p>Background-</p> <p>Neonatal abdominal ultrasound is usually performed in Nigeria to investigate neonatal symptoms rather than as a follow up to evaluate fetal abnormalities which were detected on prenatal ultrasound. The role of routine obstetric ultrasonography in the monitoring of pregnancy and identification of fetal malformations has partly contributed to lowering of fetal mortality rates. In Nigeria which has a high maternal and fetal mortality rate, many pregnant women do not have ante-natal care and not infrequently, women also deliver their babies at home and only bring the newborns to the clinics for immunization. Even when performed, most routine obstetric scans are not targeted towards the detection of fetal abnormalities.</p> <p>The aim of the present study is to evaluate the benefit of routinely performing abdominal scans on newborns with a view to detecting possible abnormalities which may have been missed ante-natally.</p> <p>Methods-</p> <p>This was a longitudinal study of 202 consecutive, apparently normal newborns. Routine clinical examination and abdominal ultrasound scans were performed on the babies by their mother's bedside, before discharge. Neonates with abnormal initial scans had follow-up scans.</p> <p>Results-</p> <p>There were 108 males and 94 females. There were 12 (5.9%) abnormal scans seen in five male and seven female neonates. Eleven of the twelve abnormalities were in the kidneys, six on the left and five on the right. Three of the four major renal anomalies- absent kidney, ectopic/pelvic kidney and two cases of severe hydronephrosis were however on the left side. There was one suprarenal abnormality on the right suspected to be a possible infected adrenal haemorrage. Nine of the abnormal cases reported for follow- up and of these, two cases had persistent severe abnormalities.</p> <p>Conclusions-</p> <p>This study demonstrated a 5.9% incidence of genito urinary anomalies on routine neonatal abdominal ultrasound in this small population. Routine obstetric USS is very useful but inadequate availability of skilled personnel and cost implications create great challenges in poor resource settings like Nigeria. However, awareness should be created so that parents who can afford such investigations can make informed decisions.</p
    • …
    corecore