85 research outputs found

    Vascular access in COVID-19 patients: Smart decisions for maximal safety

    Get PDF
    : The 2020 COVID pandemic has forced everyone to update the usual medical procedures and adapt them to a new situation characterized by a high risk of contamination of the health operator. The placement of a venous access device is no exception. In the experience of the vascular access team of our hospital, hit by the COVID epidemic in March 2020, the safety of both the patient and the staff can be ensured by an insertion bundle of few smart strategies, which include choice of long dwelling peripheral catheters (midline catheters) rather than short venous cannulas; use of power injectable peripherally inserted central catheters in the COVID patients in intensive care unit requiring a central line; use of wireless probes-easy to carry, easy to clean-for ultrasound guided venipuncture; avoidance of x-rays, using alternative methods for tip location such as intracavitary electrocardiography or trans-thoracic echocardiography; strict adoption of the barrier precautions recommended by the international guidelines

    Potential Application of Lung Ultrasound in Children with Severe Uncontrolled Asthma: Preliminary Hypothesis Based on a Case Series

    Get PDF
    : In recent years, lung ultrasound (LUS) has been increasingly used for the diagnosis of respiratory diseases in both adult and pediatric patients. However, asthma is a field in which the use of LUS is not yet well defined, or is in development. In the following case series, we describe clinical, laboratory, and radiological results, as well as detailed lung ultrasound findings of six children with asthma: some of them with acute asthma attack and with inadequately controlled allergic asthma or childhood asthma; others with acute asthma and allergic or infantile asthma adequately controlled by preventive therapy. Finally, we describe the clinical, laboratory, and imaging parameters of a child with severe allergic asthma in the absence of exacerbation. In these cases, albeit at different times, LUS played an important role in both the initial diagnostic process and follow-up. It also showed different ultrasound features depending on the severity of the individual asthma based on the type of asthmatic phenotype and control of it

    Influence of intercostal muscles contraction on sonographic evaluation of lung sliding: a physiological study on healthy subjects

    Get PDF
    objectives: to investigate the following: (a) effects of intercostal muscle contraction on sonographic assessment of lung sliding and (b) inter-rater and intra-observer agreement on sonographic detection of lung sliding and lung pulse. methods: we used Valsalva and muller maneuvers as experimental models in which closed glottis and clipped nose prevent air from entering the lungs, despite sustained intercostal muscles contraction. twenty-one healthy volunteers underwent bilateral lung ultrasound during tidal breathing, apnea, hyperventilation, and muller and valsalva maneuvers. the same expert recorded 420 B-mode clips and 420 M-mode images, independently evaluated for the presence or absence of lung sliding and lung pulse by three raters unaware of the respiratory activity corresponding to each imaging. results: during muller and valsalva maneuvers, lung sliding was certainly recognized in up to 73.0% and up to 68.7% of imaging, respectively, with a slight to fair inter-rater agreement for muller maneuver and slight to moderate for valsalva. Lung sliding was unrecognized in up to 42.0% of tidal breathing imaging, and up to 12.5% of hyperventilation imaging, with a slight to fair inter-rater agreement for both. during apnea, interpretation errors for sliding were irrelevant and inter-rater agreement moderate to perfect. even if intra-observer agreement varied among raters and throughout respiratory patterns, we found it to be higher than inter-rater reliability. conclusions: Intercostal muscles contraction produces sonographic artifacts that may simulate lung sliding. clinical studies are needed to confirm this hypothesis. we found slight to moderate inter-rater agreement and globally moderate to almost perfect intra-observer agreement for lung sliding and lung pulse. trial registration: clinical trials.gov registration number. NCT02386696

    Continuous EEG monitoring by a new simplified wireless headset in intensive care unit

    Get PDF
    Background: In critically ill patients continuous EEG (cEEG) is recommended in several conditions. Recently, a new wireless EEG headset (CerebAir®,Nihon-Kohden) is available. It has 8 electrodes, and its positioning seems to be easier than conventional systems. Aim of this study was to evaluate the feasibility of this device for cEEG monitoring, if positioned by ICU physician. Methods: Neurological patients were divided in two groups according with the admission to Neuro-ICU (Study-group:20 patients) or General-ICU (Control-group:20 patients). In Study group, cEEG was recorded by CerebAir® assembled by an ICU physician, while in Control group a simplified 8-electrodes-EEG recording positioned by an EEG technician was performed. Results: Time for electrodes applying was shorter in Study-group than in Control-group: 6.2 ± 1.1' vs 10.4 ± 2.3'; p < 0.0001. Thirty five interventions were necessary to correct artifacts in Study-group and 11 in Control-group. EEG abnormalities with or without epileptic meaning were respectively 7(35%) and 7(35%) in Study-group, and 5(25%) and 9(45%) in Control-group;p > 0.05. In Study-group, cEEG was interrupted for risk of skin lesions in 4 cases after 52 ± 4 h. cEEG was obtained without EEG technician in all cases in Study-group; quality of EEG was similar. Conclusions: Although several limitations should be considered, this simplified EEG system could be feasible even if EEG technician was not present. It was faster to position if compared with standard techniques, and can be used for continuous EEG monitoring. It could be very useful as part of diagnostic process in an emergency setting

    Bioimpedance-assessed muscle wasting and its relation to nutritional intake during the first week of ICU: a pre-planned secondary analysis of Nutriti Study

    Get PDF
    Background: Muscle mass evaluation in ICU is crucial since its loss is related with long term complications, including physical impairment. However, quantifying muscle wasting with available bedside tools (ultrasound and bioimpedance analysis) must be more primarily understood. Bioimpedance analysis (BIA) provides estimates of muscle mass and phase angle (PA). The primary aim of this study was to evaluate muscle mass changes with bioimpedance analysis during the first 7 days after ICU admission. Secondary aims searched for correlations between muscular loss and caloric and protein debt. Methods: Patients with an expected ICU-stay ≥ 72 h and the need for artificial nutritional support were evaluated for study inclusion. BIA evaluation of muscle mass and phase angle were performed at ICU admission and after 7 days. Considering the difference between ideal caloric and protein targets, with adequate nutritional macronutrients delivered, we calculated the caloric and protein debt. We analyzed the potential correlation between caloric and protein debt and changes in muscle mass and phase angle. Results: 72 patients from September 1st to October 30th, 2019 and from August 1st to October 30th, 2021 were included in the final statistical analysis. Median age was 68 [59-77] years, mainly men (72%) admitted due to respiratory failure (25%), and requiring invasive mechanical ventilation for 7 [4-10] days. Median ICU stay was 8 [6-12] days. Bioimpedance data at ICU admission and after 7 days showed that MM and PA resulted significantly reduced after 7 days of critically illness, 34.3 kg vs 30.6 kg (p < 0.0001) and 4.90° vs 4.35° (p = 0.0004) respectively. Mean muscle loss was 3.84 ± 6.7 kg, accounting for 8.4% [1-14] MM reduction. Correlation between caloric debt (r = 0.14, p = 0.13) and protein debt (r = 0.18, p = 0.13) with change in MM was absent. Similarly, no correlation was found between caloric debt (r = -0.057, p = 0.631) and protein debt (r = -0.095, p = 0.424) with changes in PA. Conclusions: bioimpedance analysis demonstrated that muscle mass and phase angle were significantly lower after 7 days in ICU. The total amount of calories and proteins does not correlate with changes in muscle mass and phase angle

    Head to toe ultrasound: a narrative review of experts’ recommendations of methodological approaches

    Get PDF
    Critical care ultrasonography (US) is widely used by intensivists managing critically ill patients to accurately and rapidly assess different clinical scenarios, which include pneumothorax, pleural effusion, pulmonary edema, hydronephrosis, hemoperitoneum, and deep vein thrombosis. Basic and advanced critical care ultrasonographic skills are routinely used to supplement physical examination of critically ill patients, to determine the etiology of critical illness and to guide subsequent therapy. European guidelines now recommend the use of US for a number of practical procedures commonly performed in critical care. Full training and competence acquisition are essential before significant therapeutic decisions are made based on the US assessment. However, there are no universally accepted learning pathways and methodological standards for the acquisition of these skills. Therefore, in this review, we aim to provide a methodological approach of the head to toe ultrasonographic evaluation of critically ill patients considering different districts and clinical applications

    Italian Society of Anesthesia, Analgesia, Resuscitation, and Intensive Care expert consensus statement on the use of lung ultrasound in critically ill patients with coronavirus disease 2019 (ITACO)

    Get PDF
    Background To produce statements based on the available evidence and an expert consensus (as members of the Lung Ultrasound Working Group of the Italian Society of Analgesia, Anesthesia, Resuscitation, and Intensive Care, SIAARTI) on the use of lung ultrasound for the management of patients with COVID-19 admitted to the intensive care unit. Methods A modified Delphi method was applied by a panel of anesthesiologists and intensive care physicians expert in the use of lung ultrasound in COVID-19 intensive critically ill patients to reach a consensus on ten clinical questions concerning the role of lung ultrasound in the following: COVID-19 diagnosis and monitoring (with and without invasive mechanical ventilation), positive end expiratory pressure titration, the use of prone position, the early diagnosis of pneumothorax- or ventilator-associated pneumonia, the process of weaning from invasive mechanical ventilation, and the need for radiologic chest imaging. Results A total of 20 statements were produced by the panel. Agreement was reached on 18 out of 20 statements (scoring 7–9; “appropriate”) in the first round of voting, while 2 statements required a second round for agreement to be reached. At the end of the two Delphi rounds, the median score for the 20 statements was 8.5 [IQR 8.9], and the agreement percentage was 100%. Conclusion The Lung Ultrasound Working Group of the Italian Society of Analgesia, Anesthesia, Resuscitation, and Intensive Care produced 20 consensus statements on the use of lung ultrasound in COVID-19 patients admitted to the ICU. This expert consensus strongly suggests integrating lung ultrasound findings in the clinical management of critically ill COVID-19 patients
    corecore