313 research outputs found

    Compromise Based Evolutionary Multiobjective Optimization Algorithm for Multidisciplinary Optimization

    Get PDF
    International audienceMultidisciplinary Design Optimization deals with engineering problems composed of several sub-problems - called disciplines - that can have antagonist goals and thus require to find compromise solutions. Moreover, the sub-problems are often multiobjective optimization problems. In this case, the compromise solutions between the disciplines are often considered as compromises between all objectives of the problem, which may be not relevant in this context. We propose two alternative definitions of the compromise between disciplines. Their implementations within the well-known NSGA-II algorithm are studied and results are discussed

    The transformation of transport policy in Great Britain? 'New Realism' and New Labour's decade of displacement activity

    Get PDF
    In a 1999 paper, Goodwin announced ‘the transformation of transport policy in Great Britain’. His central point was that consensus was emerging among policy makers and academics based on earlier work including Transport: The New Realism, which rejected previous orthodoxy that the supply of road space could and should be continually expanded to match demand. Instead a combination of investment in public transport, walking and cycling opportunities and – crucially – demand management should form the basis of transport policy to address rising vehicle use and associated increases in congestion and pollution / carbon emissions. This thinking formed the basis of the 1997 Labour government’s ‘sustainable transport’ policy, but after 13 years in power ministers neither transformed policy nor tackled longstanding transport trends. Our main aim in this paper is to revisit the concept of New Realism and re-examine its potential utility as an agent of change in British transport policy. Notwithstanding the outcome of Labour’s approach to transport policy, we find that the central tenets of the New Realism remain robust and that the main barriers to change are related to broader political and governance issues which suppress radical policy innovation

    Reduction of cardiac imaging tests during the COVID-19 pandemic: The case of Italy. Findings from the IAEA Non-invasive Cardiology Protocol Survey on COVID-19 (INCAPS COVID)

    Get PDF
    BACKGROUND: In early 2020, COVID-19 massively hit Italy, earlier and harder than any other European country. This caused a series of strict containment measures, aimed at blocking the spread of the pandemic. Healthcare delivery was also affected when resources were diverted towards care of COVID-19 patients, including intensive care wards. AIM OF THE STUDY: The aim is assessing the impact of COVID-19 on cardiac imaging in Italy, compare to the Rest of Europe (RoE) and the World (RoW). METHODS: A global survey was conducted in May–June 2020 worldwide, through a questionnaire distributed online. The survey covered three periods: March and April 2020, and March 2019. Data from 52 Italian centres, a subset of the 909 participating centres from 108 countries, were analyzed. RESULTS: In Italy, volumes decreased by 67% in March 2020, compared to March 2019, as opposed to a significantly lower decrease (p < 0.001) in RoE and RoW (41% and 40%, respectively). A further decrease from March 2020 to April 2020 summed up to 76% for the North, 77% for the Centre and 86% for the South. When compared to the RoE and RoW, this further decrease from March 2020 to April 2020 in Italy was significantly less (p = 0.005), most likely reflecting the earlier effects of the containment measures in Italy, taken earlier than anywhere else in the West. CONCLUSIONS: The COVID-19 pandemic massively hit Italy and caused a disruption of healthcare services, including cardiac imaging studies. This raises concern about the medium- and long-term consequences for the high number of patients who were denied timely diagnoses and the subsequent lifesaving therapies and procedures

    Developing a decision aid to guide public sector health policy decisions: A study protocol

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Decision aids have been developed in a number of health disciplines to support evidence-informed decision making, including patient decision aids and clinical practice guidelines. However, policy contexts differ from clinical contexts in terms of complexity and uncertainty, requiring different approaches for identifying, interpreting, and applying many different types of evidence to support decisions. With few studies in the literature offering decision guidance specifically to health policymakers, the present study aims to facilitate the structured and systematic incorporation of research evidence and, where there is currently very little guidance, values and other non-research-based evidence, into the policy making process. The resulting decision aid is intended to help public sector health policy decision makers who are tasked with making evidence-informed decisions on behalf of populations. The intent is not to develop a decision aid that will yield uniform recommendations across jurisdictions, but rather to facilitate more transparent policy decisions that reflect a balanced consideration of all relevant factors.</p> <p>Methods/design</p> <p>The study comprises three phases: a modified meta-narrative review, the use of focus groups, and the application of a Delphi method. The modified meta-narrative review will inform the initial development of the decision aid by identifying as many policy decision factors as possible and other features of methodological guidance deemed to be desirable in the literatures of all relevant disciplines. The first of two focus groups will then seek to marry these findings with focus group members' own experience and expertise in public sector population-based health policy making and screening decisions. The second focus group will examine issues surrounding the application of the decision aid and act as a sounding board for initial feedback and refinement of the draft decision aid. Finally, the Delphi method will be used to further inform and refine the decision aid with a larger audience of potential end-users.</p> <p>Discussion</p> <p>The product of this research will be a working version of a decision aid to support policy makers in population-based health policy decisions. The decision aid will address the need for more structured and systematic ways of incorporating various evidentiary sources where applicable.</p

    Disparities in Non-invasive Traditional and Advanced Testing for Coronary Artery Disease: Findings from the INCAPS-COVID 2 Study

    Get PDF
    The COVID-19 pandemic disrupted delivery of cardiovascular care including non-invasive testing protocols and test selection for evaluation of coronary artery disease (CAD). Trends in test selection among traditional versus advanced noninvasive tests for CAD during the pandemic and among countries of varying income status have not been well studied. The International Atomic Energy Agency conducted a global survey to assess pandemic-related changes in the practice of cardiovascular diagnostic testing. Site procedural volumes for noninvasive tests to evaluate CAD from March 2019 (pre-pandemic), April 2020 (onset), and April 2021 (initial recovery) were collected. We considered traditional testing modalities exercise electrocardiography (ECG), stress echocardiography, and stress single-photon emission computed tomography (SPECT), and advanced testing modalities stress cardiac magnetic resonance (CMR), coronary computed tomography angiography (CCTA), and stress positron emission tomography (PET). Survey data were obtained from 669 centers in 107 countries, reporting the performance of 367,933 studies for CAD during the study period. Compared to 2019, traditional tests were performed 14% less frequently (recovery rate 82%) in 2021 versus advanced tests which were performed 15% more frequently (128% recovery rate). CCTA, stress CMR and stress PET showed 14%, 25%, and 25% increases in volumes from 2019 to 2021, respectively. The increase in advanced testing was isolated to high- and upper-middle-income countries, with 132% recovery in advanced tests by 2021 as compared to 55% in lower-income nations. The COVID-19 pandemic exacerbated economic disparities in CAD testing practice between wealthy and poorer countries. Greater recovery rates and even new growth was observed for advanced imaging modalities but this growth was restricted to wealthy countries. Efforts to reduce practice variations in CAD testing due to economic status are warranted.<br/

    Worldwide diagnostic reference levels for single-photon emission computed tomography myocardial perfusion imaging: findings from INCAPS.

    Get PDF
    OBJECTIVES: This study sought to establish worldwide and regional diagnostic reference levels (DRLs) and achievable administered activities (AAAs) for single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). BACKGROUND: Reference levels serve as radiation dose benchmarks to compare individual laboratories against aggregated data, helping to identify sites in greatest need of dose reduction interventions. DRLs for SPECT MPI have previously been derived from national or regional registries. To date there have been no multiregional reports of DRLs for SPECT MPI from a single standardized dataset. METHODS: Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study), a cross-sectional, multinational registry of MPI protocols. A total of 7,103 studies were included. DRLs and AAAs were calculated by protocol for each world region and for aggregated worldwide data. RESULTS: The aggregated worldwide DRLs for rest-stress or stress-rest studies employing technetium Tc 99m-labeled radiopharmaceuticals were 11.2 mCi (first dose) and 32.0 mCi (second dose) for 1-day protocols, and 23.0 mCi (first dose) and 24.0 mCi (second dose) for multiday protocols. Corresponding AAAs were 10.1 mCi (first dose) and 28.0 mCi (second dose) for 1-day protocols, and 17.8 mCi (first dose) and 18.7 mCi (second dose) for multiday protocols. For stress-only technetium Tc 99m studies, the worldwide DRL and AAA were 18.0 mCi and 12.5 mCi, respectively. Stress-first imaging was used in 26% to 92% of regional studies except in North America where it was used in just 7% of cases. Significant differences in DRLs and AAAs were observed between regions. CONCLUSIONS: This study reports reference levels for SPECT MPI for each major world region from one of the largest international registries of clinical MPI studies. Regional DRLs may be useful in establishing or revising guidelines or simply comparing individual laboratory protocols to regional trends. Organizations should continue to focus on establishing standardized reporting methods to improve the validity and comparability of regional DRLs

    Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS)

    Get PDF
    Aims To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing ‘best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. Methods and results We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight ‘best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more ‘best practices' had lower EDs. Conclusion Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globall
    corecore