1,086 research outputs found

    A Novel Extraction Procedure of Contact Characteristic Parameters from Current–Voltage Curves in CdZnTe and CdTe Detectors

    Get PDF
    The estimation of the characteristic parameters of the electrical contacts in CdZnTe and CdTe detectors is related to the identification of the main transport mechanisms dominating the currents. These investigations are typically approached by modelling the current–voltage (I–V) curves with the interfacial layer–thermionic-diffusion (ITD) theory, which incorporates the thermionic emission, diffusion and interfacial layer theories into a single theory. The implementation of the ITD model in measured I–V curves is a critical procedure, requiring dedicated simplifications, several best fitting parameters and the identification of the voltage range where each transport mechanism dominates. In this work, we will present a novel method allowing through a simple procedure the estimation of some characteristic parameters of the metal–semiconductor interface in CdZnTe and CdTe detectors. The barrier height and the effects of the interfacial layer will be evaluated through the application of a new function related to the differentiation of the experimental I–V curves

    Fluid history related to the early Eocene-middle Miocene convergent system of the Northern Apennines (Italy). Constraints from structural and isotopic studies

    Get PDF
    The late Eocene-middle Miocene erosive plate boundary between the European and the Adriatic plates is exhumed in the Northem Apennines of Italy. The fossil fault zone is 500 m thick and the outcropping portion exposes the :first 5 km of its depth. At this plate boundary basai and frontal tectonic erosion incorporated unlithified, fluid-rich sediments into the fault zone. The deformation and nature of the material along the plate boundary define a fossil subduction channel. Here we couple a detailed structural analysis of the Apennine subduction channel, focusing, in particular, on calcite veins, with a stable isotope analysis to characterize the fluid regime along an active subduction channel. The 13C and 180 composition of calcite vein and host rock samples within the fault zone indicates that there is a deep metamorphic source of fluids migrating upward along the subduction channel, in addition to locally derived fluid components. Dewatering of subducting turbidites contributes significantly only in the shallowest part of the channel. Structural observations indicate fluid flow along and across the subduction channel. At deep levels fluid flow is associated with discrete deformation events on shear faults offset by dilational jogs :filled with implosion breccias. At intennediate levels deformation is stili cyclic and associated with repeated crack-and-seal events. At the shallowest levels deformation occurred, while portions of the subducting material were stili unlithi:fied. Here the deformation was quasicontinuous, without associated vein development. Both isotope and structural analyses indicate that this erosive subduction channel behaved as a weak: fault with a vertical maximum principal stres

    Poorly differentiated clusters (PDC) in colorectal cancer: what is and ought to be known.

    Get PDF
    The counting of poorly differentiated clusters of 5 or more cancer cells lacking a gland-like structure in a tumor mass has recently been identified among the histological features predictive of poor prognosis in colorectal cancer. Poorly differentiated clusters can easily be recognized in the histological sections of colorectal cancer routinely stained with haematoxylin and eosin. Despite some limitations related to specimen fragmentation, counting can also be assessed in endoscopic biopsies. Based on the number of poorly differentiated clusters that appear under a microscopic field of a ×20 objective lens (i.e., a microscopic field with a major axis of 1 mm), colorectal cancer can be graded into malignancies as follows: tumors with <5 clusters as grade 1, tumors with 5 to 9 clusters as grade 2, and tumors with ≥10 clusters as grade 3. High poorly differentiated cluster counts are significantly associated with peri-neural and lympho-vascular invasion, the presence of nodal metastases or micrometastases, as well as shorter overall and progression free survival to colorectal cancer. The morphological aspects and clinical relevance of poorly differentiated clusters counting in colorectal cancer are discussed in this review

    Tolerance without clonal expansion: Self-antigen-expressing B cells program self-reactive T cells for future deletion

    Get PDF
    B cells have been shown in various animal models to induce immunological tolerance leading to reduced immune responses and protection from autoimmunity. We show that interaction of B cells with naive T cells results in T cell triggering accompanied by the expression of negative costimulatory molecules such as PD-1, CTLA-4, B and T lymphocyte attenuator, and CD5. Following interaction with B cells, T cells were not induced to proliferate, in a process that was dependent on their expression of PD-1 and CTLA-4, but not CD5. In contrast, the T cells became sensitive to Ag-induced cell death. Our results demonstrate that B cells participate in the homeostasis of the immune system by ablation of conventional self-reactive T cells

    Predictors of HER2 gene amplification in immunohistochemistry score 2+ Early Breast Cancer according to 2018 ASCO/CAP guidelines: a single institution analysis.

    Get PDF
    Background: HER2 overexpression occurs in approximately 15-20% of invasive breast cancers (BC). From a pathological point of view HER2 positivity is defined by intense circumferential membrane complete staining in more than 10% of tumour cells in immunohistochemistry (IHC score 3+). When complete circumferential staining is weak to moderate (IHC score 2+) double probe in situ ibridation (ISH) is mandatory to define HER2 status. In 2018 ASCO/CAP guidelines were updated to provide additional guidance in HER2 equivocal cases to allow a greater discrimination between positive and negative cases. Our aim is to find predictors of HER2 positivity among IHC score 2+ early breast cancer specimens analysed according to 2018 ASCO/CAP guidelines. Patients and methods: 253 cases of early BC diagnosed at Modena Cancer Center between November 2013 and August 2017 were identified. Stage, ISH result, hormonal receptor status (HR), proliferation index (MIB1), and histological grade were captured; menopausal status was available too. All IHC score 2+ cases were reclassified according to 2018 ASCO/CAP guidelines. The association between pathological tumour features, clinical characteristics and ISH positivity was assessed using Fisher test. Results: Overall, 25.7% IHC score 2+ BC resulted HER2 amplified in double probe ISH. High tumour grade (G3 vs G1-2) and MIB1 > 20% significantly predict HER2 ISH amplification (p=0,0001). No correlation was found according to HR, stage, or menopausal status. The majority (185; 98.4%) of HER2-ve BC were reclassified as group 5 (HER2/ CEP17 ratio <2 and HER2 copy number <4 signals/cell) except for 3 specimens classified as group 4 (HER2/CEP17 RATIO <2 and HER2 copy number \ub34 but <6 signals/cell). In HER2+ve group the majority (62; 95.3%) specimens were group 1 (HER2/CEP17 RATIO >2 and HER2 copy number =4 signals/cell), no specimen was group 2, and only 3 cases were classified as group 3 (HER2/CEP17 RATIO <2 and HER2 copy number >6 signals/cell). Conclusions: In this IHC score 2+ BC series, reclassification according to 2018 ASCO/CAP guidelines identified only 4.6% group 3 and 1.6% group 4 cases. The routinely assessment of grading and proliferation index could help to predict HER2 amplification in IHC score 2+ samples even if it must not substitute ISH assay in determining eligibility for HER2 targeted therapies

    Advances in High-Energy-Resolution CdZnTe Linear Array Pixel Detectors with Fast and Low Noise Readout Electronics

    Get PDF
    Radiation detectors based on Cadmium Zinc Telluride (CZT) compounds are becoming popular solutions thanks to their high detection efficiency, room temperature operation, and to their reliability in compact detection systems for medical, astrophysical, or industrial applications. However, despite a huge effort to improve the technological process, CZT detectors’ full potential has not been completely exploited when both high spatial and energy resolution are required by the application, especially at low energies (<10 keV), limiting their application in energy-resolved photon counting (ERPC) systems. This gap can also be attributed to the lack of dedicated front-end electronics which can bring out the best in terms of detector spectroscopic performances. In this work, we present the latest results achieved in terms of energy resolution using SIRIO, a fast low-noise charge sensitive amplifier, and a linear-array pixel detector, based on boron oxide encapsulated vertical Bridgman-grown B-VB CZT crystals. The detector features a 0.25-mm pitch, a 1-mm thickness and is operated at a −700-V bias voltage. An equivalent noise charge of 39.2 el. r.m.s. (corresponding to 412 eV FWHM) was measured on the test pulser at 32 ns peaking time, leading to a raw resolution of 1.3% (782 eV FWHM) on the 59 keV line at room temperature (+20 °C) using an uncollimated 241Am, largely improving the current state of the art for CZT-based detection systems at such short peaking times, and achieving an optimum resolution of 0.97% (576 eV FWHM) at 1 µs peaking time. The measured energy resolution at the 122 keV line and with 1 µs peaking time of a 57Co raw uncollimated spectrum is 0.96% (1.17 keV). These activities are in the framework of an Italian collaboration on the development of energy-resolved X-ray scanners for material recycling, medical applications, and non-destructive testing in the food industry

    High performance platinum contacts on high-flux CdZnTe detectors

    Get PDF
    The need for direct X-ray detection under high photon flux with moderate or high energies (30–100 keV range) has strongly increased with the rise of the 4th Generation Synchrotron Light Sources, characterised by extremely brilliant beamlines, and of other applications such as spectral computed tomography in medicine and non-destructive tests for industry. The novel Cadmium Zinc Telluride (CZT) developed by Redlen Technologies can be considered the reference material for high-flux applications (HF-CZT). The enhanced charge transport properties of the holes allow the mitigation of the effects of radiation induced polarization phenomena, typically observed in standard CZT materials (LF-CZT) under high photon flux. However, standard LF-CZT electrical contacts led to inacceptable high dark leakage currents on HF-CZT devices. In this work, a detailed study on the characteristics of new optimized sputtered platinum electrical contacts on HF-CZT detectors is reported. The results from electrical and spectroscopic investigations, showed the best performances on HF-CZT detectors with platinum anode, coupled with both platinum or gold cathode. The morphology, structure, and composition of Pt/CZT contact have been analysed by means of Transmission Electron Microscopy (TEM) on microscopic lamellas obtained by Focused Ion Beam (FIB), highlighting the presence of CdTeO3 oxide at the metal semiconductor interface

    Advances in High-Energy-Resolution CdZnTe Linear Array Pixel Detectors with Fast and Low Noise Readout Electronics

    Get PDF
    : Radiation detectors based on Cadmium Zinc Telluride (CZT) compounds are becoming popular solutions thanks to their high detection efficiency, room temperature operation, and to their reliability in compact detection systems for medical, astrophysical, or industrial applications. However, despite a huge effort to improve the technological process, CZT detectors' full potential has not been completely exploited when both high spatial and energy resolution are required by the application, especially at low energies (<10 keV), limiting their application in energy-resolved photon counting (ERPC) systems. This gap can also be attributed to the lack of dedicated front-end electronics which can bring out the best in terms of detector spectroscopic performances. In this work, we present the latest results achieved in terms of energy resolution using SIRIO, a fast low-noise charge sensitive amplifier, and a linear-array pixel detector, based on boron oxide encapsulated vertical Bridgman-grown B-VB CZT crystals. The detector features a 0.25-mm pitch, a 1-mm thickness and is operated at a -700-V bias voltage. An equivalent noise charge of 39.2 el. r.m.s. (corresponding to 412 eV FWHM) was measured on the test pulser at 32 ns peaking time, leading to a raw resolution of 1.3% (782 eV FWHM) on the 59 keV line at room temperature (+20 °C) using an uncollimated 241Am, largely improving the current state of the art for CZT-based detection systems at such short peaking times, and achieving an optimum resolution of 0.97% (576 eV FWHM) at 1 µs peaking time. The measured energy resolution at the 122 keV line and with 1 µs peaking time of a 57Co raw uncollimated spectrum is 0.96% (1.17 keV). These activities are in the framework of an Italian collaboration on the development of energy-resolved X-ray scanners for material recycling, medical applications, and non-destructive testing in the food industry

    Window-Based Energy Selecting X-ray Imaging and Charge Sharing in Cadmium Zinc Telluride Linear Array Detectors for Contaminant Detection

    Get PDF
    The spectroscopic and imaging performance of energy-resolved photon counting detectors, based on new sub-millimetre boron oxide encapsulated vertical Bridgman cadmium zinc telluride linear arrays, are presented in this work. The activities are in the framework of the AVATAR X project, planning the development of X-ray scanners for contaminant detection in food industry. The detectors, characterized by high spatial (250 µm) and energy (<3 keV) resolution, allow spectral X-ray imaging with interesting image quality improvements. The effects of charge sharing and energy-resolved techniques on contrast-to-noise ratio (CNR) enhancements are investigated. The benefits of a new energy-resolved X-ray imaging approach, termed window-based energy selecting, in the detection of low- and high-density contaminants are also shown

    Awareness, treatment, and control of hypertension in the elderly in a general practice experience

    Get PDF
    In 3858 ambulatory elderly people (age greater than or equal to 65 years) prevalence of hypertension was 67.8%. The hypertensive status was unknown to both the doctor and the patient in 21.4% of cases. More than 90% of known hypertensives were treated, but hypertension could be considered as controlled in less than 30% of them
    corecore