42 research outputs found

    Sixfold improved single particle measurement of the magnetic moment of the antiproton

    Get PDF
    Our current understanding of the Universe comes, among others, from particle physics and cosmology. In particle physics an almost perfect symmetry between matter and antimatter exists. On cosmological scales, however, a striking matter/antimatter imbalance is observed. This contradiction inspires comparisons of the fundamental properties of particles and antiparticles with high precision. Here we report on a measurement of the g-factor of the antiproton with a fractional precision of 0.8 parts per million at 95% confidence level. Our value /2=2.7928465(23) outperforms the previous best measurement by a factor of 6. The result is consistent with our proton g-factor measurement gp/2=2.792847350(9), and therefore agrees with the fundamental charge, parity, time (CPT) invariance of the Standard Model of particle physics. Additionally, our result improves coefficients of the standard model extension which discusses the sensitivity of experiments with respect to CPT violation by up to a factor of 20.EU/ERC/290870-MEFUCOMax-Planck SocietyHelmholtz-GemeinschaftRIKEN Initiative Research Unit ProgramRIKEN President FundingRIKEN Pioneering Project FundingRIKEN FPR FundingRIKEN JRA ProgramMEXT/24000008Max-Planck SocietyEU/ERC Advanced Grant/290870-MEFUCOHelmholtz-GemeinschaftCERN-fellowship program

    Improved limit on the directly measured antiproton lifetime

    Get PDF
    Continuous monitoring of a cloud of antiprotons stored in a Penning trap for 405 days enables us to set an improved limit on the directly measured antiproton lifetime. From our measurements we extract a storage time of 3.15x108 equivalent antiproton-seconds, resulting in a lower lifetime limit of Tp > 10.2,a with a confidence level of 68%. This result improves the limit on charge-parity-time violation in antiproton decays based on direct observation by a factor of 7

    Guidelines for the use and interpretation of assays for monitoring autophagy (4th edition)

    Get PDF

    Effect of combining phosphodiesterase III inhibitors with St Thomas Hospital's solution used as transplantation preservative solution in isolated rat hearts

    No full text
    Improved preservation of the harvested heart with attenuation of the reperfusion injury is important for successful outcomes of cardiac transplantations. The most commonly used cardioplegic solution, to prevent ischemic changes has been St Thomas' Hospital cardioplegic solution (STHCS). However, it is neither ideal nor sufficient to prevent myocardial ischernia and reperfusion injury. Phosphodiesterase inhibitors can attenuate the damage due to the injuries of ischernia and reperfusion. In this study we sought to enrich STHCS with a phosphodiesterase inhibitor to improve preservation of cardiac functions. The harvested hearts of 24 rats were divided into four groups. All hearts were mounted on a Langendorff perfusion system. After a stabilization period, cardiac arrest was maintained by STHCS. The hearts were stored in STHCS alone or with milrinone, amrinone, or enoximone for 6 hours. The reperfusion was maintained using a modified Tyrode's solution. All hearts were compared for their preischernic and postischernic left ventricular developed pressure, +dp/dtm., -dp/dt.., duration of systole, ejection time, and time to reach peak systolic pressure. Coronary effluent was collected for lactate dehydrogenase (LDH) measurements. The initial values for all metrics were comparable between the groups. During the postreperfusion period, all hearts showed lower peak systolic pressures than the initial values. Although the arnrinone group seemed to have higher values, the 25-minute result was at the border of significance and the 30-minute value, significantly higher. All hearts showed far lower results of maximum changes in contractility during the time period (+dp/dt(max)) versus the initial values; comparisons between groups were not significant. For the parameter of maximum changes in relaxation during the time period (-dp/dt(max)), while other hearts showed lower results, the amrinone group displayed values comparable to the initial ones after 20 minutes. Comparisons between groups were insignificant. While other hearts had comparable values for time of systole, the hearts applied with milrinone reached these values after 15 minutes. Group comparison for time of ejection revealed that the results at 5-minute postreperfusion were higher in the enoximone and the amrinone groups than the milrinone group. Postreperfusion 5-minute results were higher in the enoximone and the amrinone groups than the milrinone group for time to reach peak systolic pressure. LDH levels were lowest in the amrinone group. In conclusion, our study revealed that adding phosphodiesterase inhibitors to STHCS improved peak systolic pressure and maximum changes in relaxation during the time period (-dp/dtmax, mm Hg/s). It also decreased the LDH leakage, which corresponded to the degree of ischemic tissue damage. Arnrinone seemed to result in more favorable results, which may be attributed to its additional effects on inflammation, including those on cytokines and leukocyte aggregation

    Perifoveal Chorioretinal Atrophy after Subretinal Voretigene Neparvovec-rzyl for RPE65-Mediated Leber Congenital Amaurosis

    No full text
    To report an anatomic change following subretinal injection of voretigene neparvovec-rzyl (VN) for RPE65-mediated Leber congenital amaurosis. Multicenter, retrospective chart review. Patients who underwent subretinal VN injection at each of 4 participating institutions. Patients were identified as having perifoveal chorioretinal atrophy if (1) the areas of atrophy were not directly related to the touch-down site of the subretinal cannula; and (2) the area of atrophy progressively enlarged over time. Demographic data, visual acuity, refractive error, fundus photographs, OCT, visual fields, and full-field stimulus threshold (FST) were analyzed. Outcome measures included change in visual acuity, FST, visual fields, and location of atrophy relative to subretinal bleb position. A total of 18 eyes of 10 patients who underwent subretinal injection of VN were identified as having developed perifoveal chorioretinal atrophy. Eight of 10 patients (80%) developed bilateral atrophy. The mean age was 11.6 years (range, 5–20 years), and 6 patients (60%) were male. Baseline mean logarithm of the minimum angle of resolution visual acuity and FST were 0.82 (standard deviation [SD], 0.51) and −1.3 log cd.s/m2 (SD, 0.44), respectively. The mean spherical equivalent was −5.7 diopters (D) (range, −11.50 to +1.75 D). Atrophy was identifiable at an average of 4.7 months (SD, 4.3) after surgery and progressively enlarged in all cases up to a mean follow-up period of 11.3 months (range, 4–18 months). Atrophy developed within and outside the area of the subretinal bleb in 10 eyes (55.5%), exclusively within the area of the bleb in 7 eyes (38.9%), and exclusively outside the bleb in 1 eye (5.5%). There was no significant change in visual acuity (P = 0.45). There was a consistent improvement in FST with a mean improvement of −3.21 log cd.s/m2 (P < 0.0001). Additionally, all 13 eyes with reliable Goldmann visual fields demonstrated improvement, but 3 eyes (23.1%) demonstrated paracentral scotomas related to the atrophy. A subset of patients undergoing subretinal VN injection developed progressive perifoveal chorioretinal atrophy after surgery. Further study is necessary to determine what ocular, surgical delivery, and vector-related factors predispose to this complication

    Highly sensitive superconducting circuits at ∼700 kHz with tunable quality factors for image-current detection of single trapped antiprotons

    No full text
    We developed highly-sensitive image-current detection systems based on superconducting toroidal coils and ultra-low noise amplifiers for non-destructive measurements of the axial frequencies (550\sim800\,kHz) of single antiprotons stored in a cryogenic multi-Penning-trap system. The unloaded superconducting tuned circuits show quality factors of up to 500\,000, which corresponds to a factor of 10 improvement compared to our previously used solenoidal designs. Connected to ultra-low noise amplifiers and the trap system, signal-to-noise-ratios of 30\,dB at quality factors of > 20\,000 are achieved. In addition, we have developed a superconducting switch which allows continuous tuning of the detector's quality factor, and to sensitively tune the particle-detector interaction. This allowed us to improve frequency resolution at constant averaging time, which is crucial for single antiproton spin-transition spectroscopy experiments, as well as improved measurements of the proton-to-antiproton charge-to-mass ratio.Comment: 87 (2016) 11330
    corecore