10 research outputs found

    The effect of electro-anatomical mapping on the success rate and fluoroscopy time in supra-ventricular tachycardia ablation in children:single centre retrospective study

    Get PDF
    Aims: To evaluate the effect of electro-anatomical mapping on success rate and fluoroscopy time in ablation of supraventricular tachycardia substrates in a large group of children. Methods: Patients referred from multiple centres in the Netherlands and who received a first ablation for supraventricular tachycardia substrates in the Leiden University Medical Center between 2014 and 2020 were included in this retrospective cohort study. They were divided in procedures in patients with fluoroscopy and procedures in patients using electro-anatomical mapping. Results: Outcomes of ablation of 373 electro-anatomical substrates were analysed. Acute success rate in the fluoro-group (n = 170) was 95.9% compared to 94.5% in the electro-anatomical mapping group (n = 181) (p = 0.539); recurrence rate was 6.1% in the fluoro-group and 6.4% in the electro-anatomical mapping group (p = 0.911) after a 12-months follow-up. Redo-ablations were performed in 12 cases in the fluoro-group and 10 cases in the electro-anatomical mapping group, with a success rate of 83.3% versus 80.0%, resulting in an overall success rate of 95.9% in the fluoro-group and 92.8% in the electro-anatomical mapping group (p = 0.216) after 12 months. Fluoroscopy time and dose area product decreased significantly from 16.00 ± 17.75 minutes (median ± interquartile range) to 2.00 ± 3.00 minutes (p = 0.000) and 210.5 μGym 2 ± 249.3 to 32.9 μGym 2 ± 78.6 (p = 0.000), respectively. In the fluoro-group, four complications occurred (2.0%) and in the electro-anatomical mapping group no complications occurred. Conclusion: These results demonstrate that ablations of supraventricular tachycardia substrates in children remain a highly effective and safe treatment after the introduction of electro-anatomical mapping as a standard of care, while significantly reducing fluoroscopy time and dose area product.</p

    The effect of electro-anatomical mapping on the success rate and fluoroscopy time in supra-ventricular tachycardia ablation in children:single centre retrospective study

    Get PDF
    Aims: To evaluate the effect of electro-anatomical mapping on success rate and fluoroscopy time in ablation of supraventricular tachycardia substrates in a large group of children. Methods: Patients referred from multiple centres in the Netherlands and who received a first ablation for supraventricular tachycardia substrates in the Leiden University Medical Center between 2014 and 2020 were included in this retrospective cohort study. They were divided in procedures in patients with fluoroscopy and procedures in patients using electro-anatomical mapping. Results: Outcomes of ablation of 373 electro-anatomical substrates were analysed. Acute success rate in the fluoro-group (n = 170) was 95.9% compared to 94.5% in the electro-anatomical mapping group (n = 181) (p = 0.539); recurrence rate was 6.1% in the fluoro-group and 6.4% in the electro-anatomical mapping group (p = 0.911) after a 12-months follow-up. Redo-ablations were performed in 12 cases in the fluoro-group and 10 cases in the electro-anatomical mapping group, with a success rate of 83.3% versus 80.0%, resulting in an overall success rate of 95.9% in the fluoro-group and 92.8% in the electro-anatomical mapping group (p = 0.216) after 12 months. Fluoroscopy time and dose area product decreased significantly from 16.00 +/- 17.75 minutes (median +/- interquartile range) to 2.00 +/- 3.00 minutes (p = 0.000) and 210.5 mu Gym(2) +/- 249.3 to 32.9 mu Gym(2) +/- 78.6 (p = 0.000), respectively. In the fluoro-group, four complications occurred (2.0%) and in the electro-anatomical mapping group no complications occurred. Conclusion: These results demonstrate that ablations of supra-ventricular tachycardia substrates in children remain a highly effective and safe treatment after the introduction of electro-anatomical mapping as a standard of care, while significantly reducing fluoroscopy time and dose area product

    Development of an Online, Evidence-Based Patient Information Portal for Congenital Heart Disease: A Pilot Study

    No full text
    In response to an increased need for patient information on congenital heart disease in the Netherlands, we initiated a nationwide initiative to develop an online, evidence-based patient information portal, starting with a pilot project aimed at the subgroup of patients with congenital aortic and pulmonary valve disease. We developed an information portal that aims to (1) improve patient knowledge and involvement and to subsequently reduce anxiety and decisional conflict and improve mental quality of life and (2) to support physicians in informing and communicating with their patients. The information portal was developed according to the systematic International Patient Decision Aid Standards development process employing Delphi techniques by a multidisciplinary workgroup of pediatric and adult congenital cardiologists, a congenital cardiothoracic surgeon, a psychologist, an epidemiologist, a patient representative, and web and industrial design experts. First, patients and physicians were surveyed and interviewed to assess the current state of patient information and explore their preferences and needs to determine the focus for the development of the information portal. We found that patient knowledge and numeracy are limited, reliable information is scarce, physicians inform patients selectively and patient involvement is suboptimal, and there is a need for more reliable, tailored, and multi-faceted information. Based on the findings of these surveys and interviews, a patient-tailored information portal was designed that presents evidence-based disease- and age-specific medical and psychosocial information about diagnosis, treatment, prognosis, and impact on daily life in a manner that is comprehensible and digestible for patients and that meets the needs expressed by both patients and physicians. The effect of the website on patient outcome is currently being assessed in a multicenter stepped-wedge implementation trial. The present pilot project succeeded in developing an online, evidence-based information portal that is supported by both patients and physicians. The information portal will be further developed and expanded to include all other major forms of congenital heart disease, translations into other languages, and a public information portal to serve patients' relatives and the general public at larg

    Reclassification of a likely pathogenic Dutch founder variant in KCNH2; implications of reduced penetrance

    No full text
    BACKGROUND: Variants in KCNH2, encoding the human ether a-go-go (hERG) channel that is responsible for the rapid component of the cardiac delayed rectifier K+ current (IKr), are causal to long QT syndrome type 2 (LQTS2). We identified eight index patients with a new variant of unknown significance (VUS), KCNH2:c.2717C > T:p.(Ser906Leu). We aimed to elucidate the biophysiological effect of this variant, to enable reclassification and consequent clinical decision-making. METHODS: A genotype-phenotype overview of the patients and relatives was created. The biophysiological effects were assessed independently by manual-, and automated calibrated patch clamp. HEK293a cells expressing (i) wild-type (WT) KCNH2, (ii) KCNH2-p.S906L alone (homozygous, Hm) or (iii) KCNH2-p.S906L in combination with WT (1:1) (heterozygous, Hz) were used for manual patching. Automated patch clamp measured the variants function against known benign and pathogenic variants, using Flp-In T-rex HEK293 KCNH2-variant cell lines. RESULTS: Incomplete penetrance of LQTS2 in KCNH2:p.(Ser906Leu) carriers was observed. In addition, some patients were heterozygous for other VUSs in CACNA1C, PKP2, RYR2 or AKAP9. The phenotype of carriers of KCNH2:p.(Ser906Leu) ranged from asymptomatic to life-threatening arrhythmic events. Manual patch clamp showed a reduced current density by 69.8 and 60.4% in KCNH2-p.S906L-Hm and KCNH2-p.S906L-Hz, respectively. The time constant of activation was significantly increased with 80.1% in KCNH2-p.S906L-Hm compared with KCNH2-WT. Assessment of KCNH2-p.S906L-Hz by calibrated automatic patch clamp assay showed a reduction in current density by 35.6%. CONCLUSION: The reduced current density in the KCNH2-p.S906L-Hz indicates a moderate loss-of-function. Combined with the reduced penetrance and variable phenotype, we conclude that KCNH2:p.(Ser906Leu) is a low penetrant likely pathogenic variant for LQTS2

    Reclassification of a likely pathogenic Dutch founder variant in KCNH2; implications of reduced penetrance

    Get PDF
    BACKGROUND: Variants in KCNH2, encoding the human ether a-go-go (hERG) channel that is responsible for the rapid component of the cardiac delayed rectifier K+ current (IKr), are causal to long QT syndrome type 2 (LQTS2). We identified eight index patients with a new variant of unknown significance (VUS), KCNH2:c.2717C > T:p.(Ser906Leu). We aimed to elucidate the biophysiological effect of this variant, to enable reclassification and consequent clinical decision-making. METHODS: A genotype-phenotype overview of the patients and relatives was created. The biophysiological effects were assessed independently by manual-, and automated calibrated patch clamp. HEK293a cells expressing (i) wild-type (WT) KCNH2, (ii) KCNH2-p.S906L alone (homozygous, Hm) or (iii) KCNH2-p.S906L in combination with WT (1:1) (heterozygous, Hz) were used for manual patching. Automated patch clamp measured the variants function against known benign and pathogenic variants, using Flp-In T-rex HEK293 KCNH2-variant cell lines. RESULTS: Incomplete penetrance of LQTS2 in KCNH2:p.(Ser906Leu) carriers was observed. In addition, some patients were heterozygous for other VUSs in CACNA1C, PKP2, RYR2 or AKAP9. The phenotype of carriers of KCNH2:p.(Ser906Leu) ranged from asymptomatic to life-threatening arrhythmic events. Manual patch clamp showed a reduced current density by 69.8 and 60.4% in KCNH2-p.S906L-Hm and KCNH2-p.S906L-Hz, respectively. The time constant of activation was significantly increased with 80.1% in KCNH2-p.S906L-Hm compared with KCNH2-WT. Assessment of KCNH2-p.S906L-Hz by calibrated automatic patch clamp assay showed a reduction in current density by 35.6%. CONCLUSION: The reduced current density in the KCNH2-p.S906L-Hz indicates a moderate loss-of-function. Combined with the reduced penetrance and variable phenotype, we conclude that KCNH2:p.(Ser906Leu) is a low penetrant likely pathogenic variant for LQTS2

    Patient information portal for congenital aortic and pulmonary valve disease: A stepped-wedge cluster randomised trial

    Get PDF
    Background In response to an increased need for patient information in congenital heart disease, we previously developed an online, evidence-based information portal for patients with congenital aortic and pulmonary valve disease. To assess its effectiveness, a stepped-wedge cluster randomised trial was conducted. Methods Adult patients and caregivers of paediatric patients with congenital aortic and/or pulmonary valve disease and/or tetralogy of Fallot who visited the outpatient clinic at any of the four participating centres in the Netherlands between 1 March 2016-1 July 2017 were prospectively included. The intervention (information portal) was introduced in the outpatient clinic according to a stepped-wedge randomised design. One month after outpatient clinic visit, each participant completed a questionnaire on disease-specific knowledge, anxiety, depression, mental quality of life, involvement and opinion/attitude concerning patient information and involvement. Results 343 participants were included (221 control, 122 intervention). Cardiac diagnosis (p=0.873), educational level (p=0.153) and sex (p=0.603) were comparable between the two groups. All outcomes were comparable between groups in the intention-to-treat analyses. However, only 51.6% of subjects in the intervention group (n=63) reported actually visiting the portal. Among these subjects (as-treated), disease-specific knowledge (p=0.041) and mental health (p=0.039) were significantly better than in control subjects, while other baseline and outcome variables were comparable. Conclusion Even after being invited by their cardiologists, only half of the participants actually visited the information portal. Only in those participants that actually visited the portal, knowledge of disease and mental health were significantly better. This underlines the importance of effective implementation of online evidence-based patient information portals in clinical practice

    Cortical tracking of speech in noise accounts for reading strategies in children

    No full text
    corecore