165 research outputs found
Coronary computed tomography angiography with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination
Aims To evaluate the feasibility and image quality of coronary computed tomography angiography (CCTA) acquisition with a submillisievert fraction of effective radiation dose using model-based iterative reconstruction (MBIR) for noise reduction. Methods and results In 42 patients undergoing standard low-dose (100-120 kV; 450-700 mA) and additional ultra-low-dose CCTA (80-100 kV; 150-210 mA) reconstructed with MBIR, segmental image quality was graded on a four-point scale [(i): non-evaluative, (ii): good, (iii): adequate, and (iv): excellent]. Signal-to-noise ratio (SNR) was calculated dividing left main artery (LMA) and right coronary artery (RCA) attenuation by the aortic root noise. Over a wide range of body mass index (18-40 kg/m2), the estimated median radiation dose exposure was 1.19 mSv [interquartile range (IQR): 1.07-1.30 mSv] for standard and 0.21 mSv (IQR: 0.18-0.23 mSv) for ultra-low-dose CCTA (P < 0.001). The median image quality score per segment was 3.5 (IQR: 3.0-4.0) in standard CCTA vs. 3.5 (IQR: 2.5-4.0) in ultra-low dose with MBIR (P = 0.29). Diagnostic image quality (scores 2-4) was found in 98.7 vs. 97.8% coronary segments (P = 0.36). Introduction of MBIR for ultra-low-dose CCTA resulted in a significant increase in SNR (P < 0.001) for LMA (from 15 ± 5 to 29 ± 7) and RCA (from 14 ± 4 to 27 ± 6) despite 82% dose reduction. Conclusion Coronary computed tomography angiography acquisition with diagnostic image quality is feasible at an ultra-lowradiation dose of 0.21 mSv, e.g. in the range reported for a postero-anterior and lateral chest X-ra
Diagnostic accuracy of computed tomography coronary angiography and evaluation of stress-only single-photon emission computed tomography/computed tomography hybrid imaging: comparison of prospective electrocardiogram-triggering vs. retrospective gating
Aims To determine diagnostic accuracy, effective radiation dose, and potential value of computed tomography coronary angiography (CTCA) for hybrid imaging with single-photon emission computed tomography (SPECT) comparing prospective electrocardiogram (ECG)-triggering vs. retrospective ECG-gating. Methods and results Two hundred patients underwent standard myocardial stress/rest- SPECT perfusion imaging, which served as standard of reference. One hundred consecutive patients underwent 64-slice CTCA using prospective ECG-gating, and were compared with 100 patients who had previously undergone CTCA using retrospective ECG-gating. For predicting ischaemia, CTCA with prospective ECG-triggering and a stenosis cut-off >50% had a per-vessel sensitivity, specificity, negative, and positive predictive value of 100, 84, 100, and 30%; respective values for CTCA with retrospective ECG-gating were similar (P = n.s.): 86, 83, 98, and 33%. Combining CTCA with stress-only SPECT revealed 100% clinical agreement with regard to perfusion defects, and provided additional information in half the patients on preclinical coronary findings. Effective radiation dose was 2.2 ± 0.7 mSv for CTCA with prospective ECG-triggering, and 19.7 ± 4.2 mSv with retrospective ECG-gating (P < 0.001) (5.4 ± 0.8 vs. 24.1 ± 4.3 mSv for hybrid imaging). Conclusion Prospective ECG-triggering for CTCA reduces radiation dose by almost 90% without affecting diagnostic performance. Combined imaging with stress-only SPECT is an attractive alternative to standard stress/rest-SPECT for evaluation of coronary artery disease, offering additional information on preclinical atherosclerosi
Pathological completion in the intact visual field of hemianopia patients
We investigated figure segregation in the intact visual field (VF) of hemianopia patients. Three patients and matched controls performed a Yes–No figure detection task, where square or square fragments were embedded in a background of randomly oriented Gabor elements. We varied orientation and number of the fragment elements, stimulus eccentricity and background density (BD). Figure detection was impaired in all three patients in the entire intact VF, but potentially more pronounced in patients with cortical lesions. “Pathological completion” was most frequently observed for high BDs and for square fragments oriented towards the blind hemifield. Our findings confirm contour integration deficits in the intact VF of hemianopia patients. Further, our results indicate that (1) contour integration deficits are exacerbated by contextual interaction and (2) “pathological completion” appears to be more likely associated with lesions of cortical rather than geniculo-striate origin. The deficits point to increased lateral suppressive inputs from background elements
Prognostic value of cardiac hybrid imaging integrating single-photon emission computed tomography with coronary computed tomography angiography
Aims Although cardiac hybrid imaging, fusing single-photon emission computed tomography (SPECT) myocardial perfusion imaging with coronary computed tomography angiography (CCTA), provides important complementary diagnostic information for coronary artery disease (CAD) assessment, no prognostic data exist on the predictive value of cardiac hybrid imaging. Hence, the aim of this study was to assess the prognostic value of hybrid SPECT/CCTA images. Methods and results Of 335 consecutive patients undergoing a 1-day stress/rest 99mTc-tetrofosmin SPECT and a CCTA, acquired on stand-alone scanners and fused to obtain cardiac hybrid images, follow-up was obtained in 324 patients (97%). Survival free of all-cause death or non-fatal myocardial infarction (MI) and free of major adverse cardiac events (MACE: death, MI, unstable angina requiring hospitalization, coronary revascularizations) was determined using the Kaplan-Meier method for the following groups: (i) stenosis by CCTA and matching reversible SPECT defect; (ii) unmatched CCTA and SPECT finding; and (iii) normal finding by CCTA and SPECT. Cox's proportional hazard regression was used to identify independent predictors for cardiac events. At a median follow-up of 2.8 years (25th-75th percentile: 1.9-3.6), 69 MACE occurred in 47 patients, including 20 death/MI. A corresponding matched hybrid image finding was associated with a significantly higher death/MI incidence (P < 0.005) and proved to be an independent predictor for MACE. The annual death/MI rate was 6.0, 2.8, and 1.3% for patients with matched, unmatched, and normal findings. Conclusion Cardiac hybrid imaging allows risk stratification in patients with known or suspected CAD. A matched defect on hybrid image is a strong predictor of MAC
Inter-scan variability of coronary artery calcium scoring assessed on 64-multidetector computed tomography vs. dual-source computed tomography: a head-to-head comparison
Aims Coronary artery calcium (CAC) scoring has emerged as a tool for risk stratification and potentially for monitoring response to risk factor modification. Therefore, repeat measurements should provide robust results and low inter-scanner variability for allowing meaningful comparison. The purpose of this study was to investigate inter-scanner variability of CAC for Agatston, volume, and mass scores by head-to-head comparison using two different cardiac computed tomography scanners: 64-detector multislice CT (MSCT) and 64-slice dual-source CT (DSCT). Methods and results Thirty patients underwent CAC measurements on both 64-MSCT (GE LightSpeed XT scanner: 120 kV, 70 mAs, 2.5 mm slices) and 64-DSCT (Siemens Somatom Definition: 120 kV, 80 mAs, 3 mm slices) within <100 days (0-97). Retrospective intra-scan comparison revealed an excellent correlation. The excellent intra-scan (inter-observer) agreement was documented by narrow limits of agreement and a correlation coefficient of variation (COV) of r ≥ 0.99 (P < 0.001) for all CAC scores with a low COV for both scanners (64-MSCT/64-DSCT), i.e. Agatston (2.0/2.1%), mass (3.0/2.0%), and volume (4.7/3.9%). Inter-scanner comparison revealed larger Bland-Altman (BA) limits of agreement, despite high correlation (r ≥ 0.97) for all scores, with COV at 15.1, 21.6, and 44.9% for Agatston, mass, and volume scores. The largest BA limits were observed for volume scores (−1552.8 to 574.2), which was massively improved (−241.0 to 300.4, COV 11.5%) after reanalysing the 64-DSCT scans (Siemens) with GE software/workstation (while Siemens software/workstation does not allow cross-vendor analysis). Phantom measurements confirmed overestimation of volume scores by ‘syngo Ca-Scoring' (Siemens) software which should therefore be reviewed (vendor has been notified). Conclusion Intra- and inter-scan agreement of CAC measurement in a given data set is excellent. Inter-scanner variability is reasonable, particularly for Agatston units in the clinically most relevant range <1000. The use of different software solutions has a greater influence particularly on volume scores than the use of different scanner type
Impact of cardiac hybrid single-photon emission computed tomography/computed tomography imaging on choice of treatment strategy in coronary artery disease
Aims Cardiac hybrid imaging by fusing single-photon emission computed tomography (SPECT) myocardial perfusion imaging with coronary computed tomography angiography (CCTA) provides important complementary diagnostic information for coronary artery disease (CAD) assessment. We aimed at assessing the impact of cardiac hybrid imaging on the choice of treatment strategy selection for CAD. Methods and results Three hundred and eighteen consecutive patients underwent a 1 day stress/rest 99mTc-tetrofosmin SPECT and a CCTA on a separate scanner for evaluation of CAD. Patients were divided into one of the following three groups according to findings in the hybrid images obtained by fusing SPECT and CCTA: (i) matched finding of stenosis by CCTA and corresponding reversible SPECT defect; (ii) unmatched CCTA and SPECT finding; (iii) normal finding by both CCTA and SPECT. Follow-up was confined to the first 60 days after hybrid imaging as this allows best to assess treatment strategy decisions including the revascularization procedure triggered by its findings. Hybrid images revealed matched, unmatched, and normal findings in 51, 74, and 193 patients. The revascularization rate within 60 days was 41, 11, and 0% for matched, unmatched, and normal findings, respectively (P< 0.001 for all inter-group comparisons). Conclusion Cardiac hybrid imaging with SPECT and CCTA provides an added clinical value for decision making with regard to treatment strategy for CA
CT coronary angiography: impact of adapted statistical iterative reconstruction (ASIR) on coronary stenosis and plaque composition analysis
To assess the impact of adaptive statistical iterative reconstruction (ASIR) on coronary plaque volume and composition analysis as well as on stenosis quantification in high definition coronary computed tomography angiography (CCTA). We included 50 plaques in 29 consecutive patients who were referred for the assessment of known or suspected coronary artery disease (CAD) with contrast-enhanced CCTA on a 64-slice high definition CT scanner (Discovery HD 750, GE Healthcare). CCTA scans were reconstructed with standard filtered back projection (FBP) with no ASIR (0 %) or with increasing contributions of ASIR, i.e. 20, 40, 60, 80 and 100 % (no FBP). Plaque analysis (volume, components and stenosis degree) was performed using a previously validated automated software. Mean values for minimal diameter and minimal area as well as degree of stenosis did not change significantly using different ASIR reconstructions. There was virtually no impact of reconstruction algorithms on mean plaque volume or plaque composition (e.g. soft, intermediate and calcified component). However, with increasing ASIR contribution, the percentage of plaque volume component between 401 and 500 HU decreased significantly (p < 0.05). Modern image reconstruction algorithms such as ASIR, which has been developed for noise reduction in latest high resolution CCTA scans, can be used reliably without interfering with the plaque analysis and stenosis severity assessment
Combination of computed tomography angiography with coronary artery calcium score for improved diagnosis of coronary artery disease: a collaborative meta-analysis of stable chest pain patients referred for invasive coronary angiography
OBJECTIVES: Coronary computed tomography angiography (CCTA) has higher diagnostic accuracy than coronary artery calcium (CAC) score for detecting obstructive coronary artery disease (CAD) in patients with stable chest pain, while the added diagnostic value of combining CCTA with CAC is unknown. We investigated whether combining coronary CCTA with CAC score can improve the diagnosis of obstructive CAD compared with CCTA alone.
METHODS: A total of 2315 patients (858 women, 37%) aged 61.1 ± 10.2 from 29 original studies were included to build two CAD prediction models based on either CCTA alone or CCTA combined with the CAC score. CAD was defined as at least 50% coronary diameter stenosis on invasive coronary angiography. Models were built by using generalized linear mixed-effects models with a random intercept set for the original study. The two CAD prediction models were compared by the likelihood ratio test, while their diagnostic performance was compared using the area under the receiver-operating-characteristic curve (AUC). Net benefit (benefit of true positive versus harm of false positive) was assessed by decision curve analysis.
RESULTS: CAD prevalence was 43.5% (1007/2315). Combining CCTA with CAC improved CAD diagnosis compared with CCTA alone (AUC: 87% [95% CI: 86 to 89%] vs. 80% [95% CI: 78 to 82%]; p < 0.001), likelihood ratio test 236.3, df: 1, p < 0.001, showing a higher net benefit across almost all threshold probabilities.
CONCLUSION: Adding the CAC score to CCTA findings in patients with stable chest pain improves the diagnostic performance in detecting CAD and the net benefit compared with CCTA alone.
CLINICAL RELEVANCE STATEMENT: CAC scoring CT performed before coronary CTA and included in the diagnostic model can improve obstructive CAD diagnosis, especially when CCTA is non-diagnostic.
KEY POINTS:
• The combination of coronary artery calcium with coronary computed tomography angiography showed significantly higher AUC (87%, 95% confidence interval [CI]: 86 to 89%) for diagnosis of coronary artery disease compared to coronary computed tomography angiography alone (80%, 95% CI: 78 to 82%, p < 0.001).
• Diagnostic improvement was mostly seen in patients with non-diagnostic C.
• The improvement in diagnostic performance and the net benefit was consistent across age groups, chest pain types, and genders
- …